KITOZER 32A static transfer switch is a compact semiconductor-based dual-source transfer device designed for single-phase critical loads that cannot tolerate even milliseconds of power interruption. Built with SCR thyristor stacks and a dedicated microprocessor controller, the STS transfers the connected load between preferred utility power and backup source in less than four milliseconds, which is far faster than any mechanical automatic transfer switch. The unit ships in a wall-mount plastic and metal enclosure suitable for network cabinets, edge computing rooms, small retail point-of-sale systems, and security surveillance equipment. Every transfer decision is based on real-time voltage, frequency, and phase-angle measurement, so the controller never connects two out-of-phase sources together. The front panel provides clear indication of source health, active source, and fault status, allowing on-site staff to confirm operation at a glance.
Because the switching elements are fully electronic, the STS produces no audible noise, no contact bounce, and no arc wear during its service life. This makes it ideal for quiet office environments, recording studios, and medical rooms where mechanical clatter would be unacceptable. The controller also includes a test mode that simulates source failure so maintenance teams can verify transfer operation without waiting for a real utility event.
Technical Specifications
Rated current 32A, rated voltage 230V single phase 50/60Hz, SCR static transfer time below 4ms, break-before-make logic, preferred source programmable via front panel buttons, voltage window adjustable from 180V to 260V, frequency window 47Hz to 53Hz, LED indicators for source healthy, source active, transfer in progress, and fault alarm. Communication options include RS485 Modbus RTU and dry-contact alarm relay outputs rated 5A 250VAC. Operating temperature range minus 10C to plus 55C, storage temperature minus 25C to plus 70C, relative humidity up to 95 percent non-condensing. Protection class IP20, dimensions 320mm wide by 220mm deep by 160mm high, weight 6kg. CE and IEC 60947 certified, KITOZER brand, five year warranty.
Application Scenarios
The KITOZER 32A STS is commonly deployed at edge computing nodes, small data center remote cabinets, ATM kiosks, retail self-service terminals, hospital diagnostic instruments, broadcasting studio equipment, and industrial PLC control panels. Any load that contains a switching power supply, a solid-state drive, or a sensitive microprocessor benefits from sub-cycle transfer because a 20 millisecond mechanical switch event is enough to reset most server power supplies. The unit is also used in dual-channel security systems where recording servers, access controllers, and network switches must stay online during scheduled utility maintenance or generator changeover. Installers typically mount the STS immediately after the two source incomers and before the UPS or directly ahead of the critical load.
Additional applications include point-of-sale terminals in retail chains, hotel reservation servers, casino gaming machines, and small PBX telephone systems. In each case, the load is sensitive enough that a brief dropout would trigger a reboot, data loss, or a transaction error. The STS removes that risk by ensuring that source changeover happens faster than the hold-up time of the load power supply. The unit can also be used as the preferred feed selector between two utility meters in dual-tariff installations, automatically choosing the cheaper supply during off-peak hours.
Advantages and Features
The primary advantage is zero-break transfer. Mechanical contacts wear out, arc, and produce milliseconds of dead time, while SCR switches have no moving contacts and no arc. The controller offers programmable transfer inhibit, so engineers can lock the load on the generator during testing or lock it on utility during maintenance without any physical wire changes. Front-panel diagnostics log the last ten transfer events with timestamp, source voltage at transfer, and fault reason, which shortens root-cause analysis after power incidents. The unit also accepts a remote inhibit contact, allowing the building management system to force a preferred source. Because the SCR path is fully electronic, audible noise is absent and electromagnetic interference is contained within the shielded enclosure.
The compact footprint means the STS fits in shallow wall cavities and small network cabinets where a mechanical ATS would not fit. The Modbus RTU option allows the unit to be integrated into remote monitoring platforms, so operators know the source status without walking to the cabinet. The five year warranty reflects the low failure rate of the solid-state design. Spare controllers are field-replaceable in minutes, minimizing mean time to repair. The SCR stacks are rated for continuous overload above 125 percent of nominal for short periods, tolerating motor inrush and capacitor charging currents without stress.
Installation and Maintenance
Mount the STS on a vertical wall or inside a 19-inch cabinet using the included bracket. Connect source one and source two to their labeled terminals, then route the load cable to the output. Torque all power lugs to the value printed on the enclosure label, and verify torque again after the first 50 hours of operation. The controller requires a warm-up period of one minute after power-up before automatic transfer is enabled. Routine maintenance consists of quarterly visual inspection, annual torque check, and an annual transfer test under load using the front-panel test button. Keep ventilation slots clear and do not paint or cover the SCR heatsink. Replacement of the controller board is field-serviceable and takes less than 20 minutes.
During installation, verify that both sources are within the same nominal voltage and frequency range, and check that phase rotation is identical on both inputs. If the backup source is a small generator, confirm that the generator can stabilize within the STS pickup window, otherwise extend the delay-on-make timer. The Modbus connection should use shielded twisted pair, daisy-chained, with the shield grounded at one end. Keep the enclosure door closed during operation to prevent accidental contact with live terminals. For sites with high dust or moisture, an optional IP54 enclosure upgrade is available.
Price
From $980/pc. Contact +86 13922289957 for STS quotation, factory lead time, and OEM customization.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com