Table of Contents
ToggleProduct Overview
The KITOZER 630A three-phase static transfer switch is a floor-standing power continuity system built for medium data halls, industrial process distribution, and large commercial building main switchboards where two independent three-phase feeds must be alternated without interrupting critical loads. The unit uses heavy-duty inverse-parally SCR stacks per phase, isolated gate drive circuits, and a microprocessor controller that samples both sources every half cycle to decide the optimal instant for transfer. Because the commutation is performed by semiconductors rather than mechanical contacts, transfer occurs in under four milliseconds even at 630A, and there is no contact bounce, no arc chutes to service, and no contactor rating degradation after repeated operations. The controller continuously compares source A and source B voltage magnitude, frequency, and phase angle, and it will only transfer when the target source is within the programmed window and, when desired, in synchronism with the present source to eliminate transient torque on motor loads. A full maintenance bypass compartment is integrated, allowing the SCR blocks and control electronics to be isolated and serviced while the load is carried directly from the preferred source through the bypass breaker.
Technical Specifications
Rating: 630A continuous, 400VAC three phase plus neutral, 50 or 60Hz. Transfer: SCR static, break-before-make, typical 4ms, maximum 8ms; optional synchronized transfer mode for motor loads. Source monitoring: three phase under voltage, over voltage, unbalance, frequency window, phase rotation, and phase loss on both feeds. Programmable voltage band 320V to 460V, frequency band 47Hz to 63Hz, transfer inhibit delay and re-transfer delay adjustable. Cooling: forced air with redundant fans, hot swap fan modules. Metering: true RMS voltage and current on each phase and source, active and reactive power, energy, THD voltage and current, on front LCD. Communication: dual Ethernet Modbus TCP, RS485 Modbus RTU, optional SNMP, Web HMI, BACnet. Protection: SCR stack over temperature, over current with fast acting semiconductor fuses, source reverse phase, and load earth leakage monitoring option. Cabinet: floor standing IP32, dimensions tailored, operating 0 to 40 degrees C. Standards: CE, IEC 60947, UL listed option, 5 year warranty.
Application Scenarios
This 630A STS is deployed wherever a medium-sized critical load must be fed from two utility incomers or from utility plus generator without a mechanical transfer delay. Typical sites include enterprise data centers with 200 to 500kW IT load, semiconductor and pharmaceutical manufacturing process lines that cannot tolerate even a half-cycle outage, hospital central power distribution feeding operating rooms and imaging, large shopping mall life safety systems, and offshore or oil and gas control rooms. It is also commonly installed upstream of a parallel UPS system, where the UPS itself only sees one source but that source must be seamlessly selectable between utility A and utility B. For motor-heavy loads such as chillers, compressors, and pumps, the optional synchronized transfer mode closes the SCRs only when the two sources are within a small phase angle window, preventing the momentary voltage collapse that an out-of-sync transfer would cause on motor busbars.
Key Advantages
The core advantage is transfer speed at high current. A mechanical 630A automatic transfer switch typically takes 50 to 150 milliseconds to contact, which is long enough to cause UPS battery discharge, motor contactor dropout, and process trips. The KITOZER STS stays under 8ms across the full rating. Second, redundant forced-air cooling and hot-swap fans mean a fan failure is not a derate event, it is a routine replacement during running hours. Third, the embedded power quality metering gives facility managers per-source voltage, current, and harmonic data that can be trended in the DCIM or BMS platform, revealing which incomer is degrading before it causes an event. Fourth, the synchronized transfer option protects motor and transformer loads that would otherwise see a nasty transient. Fifth, the maintenance bypass is rated to carry the full 630A load, so servicing the SCR blocks does not require a load outage. Finally, dual Ethernet and SNMP support modern remote monitoring without gateways.
Installation and Maintenance Recommendations
Install on a level concrete plinth, keep the cabinet away from conductive dust, corrosive gas, and direct sunlight, and leave front and side clearance rated for cabinet depth plus 1 meter for servicing. Size upstream and downstream cables and busbar stubs for 630A continuous with appropriate derating, and coordinate protection so the STS semiconductor fuses coordinate with upstream MCCBs. On commissioning, calibrate the voltage and frequency windows to the actual supply, set the transfer and re-transfer delays, and run a forced transfer on each source with a real load. Verify that the maintenance bypass selector mechanically interlocks with the SCR compartment so the two cannot be paralleled accidentally. Maintenance: inspect torque on power terminals annually, clean fan filters or replace hot-swap fans on schedule, read the event log and power quality trends every quarter, and exercise the bypass selector once per year. Keep spare gate boards, fuses, and a fan module in spares store. Trend source voltage over time; a slow downward drift on one incomer is the earliest warning of a failing transformer or utility issue.
Price
From $18,600 per piece. Contact the factory for synchronized transfer option, SNMP, and site-specific cabinet drawings. Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com