The KITOZER 63A three phase static transfer switch provides seamless dual-source power continuity for small and medium data center UPS input feeds, medical imaging departments, industrial automation production lines, and broadcast transmission studios. The unit uses a three-phase SCR commutation assembly to transfer the load between two independent three phase sources in under four milliseconds, eliminating the ride-through gap that mechanical automatic transfer switches introduce. Because there is no contactor chatter and no mechanical inertia, the load voltage waveform remains essentially undisturbed through the transfer event, which protects sensitive IT equipment from the voltage notches and spikes that often precede hard drive failures and logic board resets. The KITOZER 63A STS is built in a floor-standing or wall-mountable metal cabinet with hinged front door, and it integrates a programmable controller, metering instruments, and a maintenance bypass switch into a single turnkey assembly.
Technical Specifications
Rated current is 63A continuous at 40 degrees Celsius ambient, three phase four wire nominal 400V line-to-line and 230V line-to-neutral, 50 Hz or 60 Hz. The SCR stacks are rated for 1600V reverse blocking voltage and are fitted with fast semiconductor fuses for branch short-circuit protection. Transfer time is less than 4 milliseconds from the instant the preferred source trips outside its adjustable voltage or frequency window. Source sensing windows are fully programmable: under voltage threshold from 187V to 264V line-to-neutral, over voltage threshold up to 280V, under frequency from 48 Hz to 50 Hz, and over frequency up to 52 Hz. The controller performs continuous phase rotation detection and will inhibit transfer if the two sources are out of phase by more than 120 degrees, preventing destructive cross-tie. Front panel LCD displays per-phase source and output voltage, per-phase load current, load percentage, source frequency, internal SCR temperature, and last transfer event. Communication ports include RS485 Modbus RTU, optional Ethernet Modbus TCP, and optional SNMP slot. Dry contacts include source A fail, source B fail, on bypass, general alarm, and remote transfer inhibit. Cooling is natural convection for 63A rating. Operating temperature range is 0 to 40 degrees Celsius for full rating, derating linearly above 40 degrees. Protection rating IP20. CE marked and tested to IEC 60947 standards.
Applications
The 63A three phase STS is commonly used ahead of 10 kVA to 20 kVA online double conversion UPS systems in small enterprise server rooms, in dental and hospital imaging equipment that cannot tolerate even brief source interruption, in semiconductor test equipment racks, in broadcast and television transmitter auxiliary power panels, and in railway signaling equipment rooms. It is also deployed in small financial core banking systems where two independent utility feeds are available but the customer wants zero-break switching instead of relying solely on the UPS battery ride-through. Generator integration is supported through a programmable engine start contact and a warm-up delay timer so the STS waits until the generator voltage and frequency are stable before transferring the load.
Advantages and Features
The KITOZER 63A STS offers true break-before-make semiconductor switching with no overlap between sources, so reverse feeding of the upstream transformer is impossible. The controller includes a programmable transfer inhibit feature that can be triggered by an external contact from the generator management system, preventing premature transfer during generator cranking. The unit logs the last 500 events with timestamp, RMS voltage snapshot, current snapshot, and SCR temperature at the time of transfer. A web HMI option allows operators to view status, change settings, and download event logs from any standard browser on the local area network. The maintenance bypass is a fully rated manual switch that isolates the SCR section while feeding the load directly, so technicians can service the STS without taking the load offline. The SCR sections are modular and field replaceable, reducing mean time to repair. Because there are no moving contacts, the expected service life is measured in decades rather than in tens of thousands of mechanical operations.
Installation and Maintenance Recommendations
Install the STS in a clean, dry, temperature controlled room with adequate clearance for front door opening and rear cable access. Route the two source cables and the load cable through the bottom gland plate and terminate them on the labeled copper busbars with ferrules or cable lugs tightened to the recommended torque. Verify that the two upstream sources are solidly grounded and that the neutral and ground bonding arrangements on each source are compatible before energizing. During commissioning, run a source A fail test, a source B fail test, a phase sequence verification, a bypass transfer test, and a communication loop test with the upstream monitoring system. After commissioning, inspect the SCR heat sinks and cooling fans during annual preventive maintenance visits, and download the event log to confirm no unexplained transfers have occurred. Keep the firmware up to date by requesting the latest release from KITOZER technical support. The five year warranty covers all internal electronic and semiconductor components.
Price
From $2,380 per piece. Contact KITOZER for factory pricing, lead time, and custom options including higher IP ratings, additional communication protocols, or coordinated generator control panels.