KITOZER SVG 200kVar Static Var Generator For Power Factor

Product Overview

The KITOZER SVG-200 static var generator is a three phase voltage source inverter based compensator that dynamically supplies or absorbs reactive power to maintain power factor near unity and stabilize voltage. Unlike traditional capacitor banks, the SVG uses IGBT switching with instant response, making it ideal for welding loads, elevator loads, VFD driven motors, and renewable energy systems where reactive power fluctuates rapidly. The 200 kVar rating compensates a 1000 kVA to 1500 kVA transformer load and eliminates utility penalties for low power factor.

The SVG consists of a three phase IGBT voltage source inverter, a DC link capacitor, an LCL output filter, and a digital controller. The controller measures load current via external CT, extracts the reactive and harmonic components, and commands the inverter to inject canceling current in real time. The result is unity power factor at the grid connection point and reduced current distortion. The unit is cabinet mounted with forced air cooling, touch screen HMI, and communication ports.

Technical Specifications

Rated capacity 200 kVar, three phase three wire, 400 V, 50 Hz. Response time less than 10 ms. IGBT based voltage source inverter. Power factor correction to 0.99 leading or lagging. Harmonic filtering 2nd to 25th up to rated current. Overload 1.2 times for 1 minute. Switching frequency 8 kHz. Cooling forced air. Enclosure IP20. Control panel touch screen, Modbus TCP, dry contacts. Efficiency 98 percent. Complies with IEC 61000, IEEE 519.

The touch screen HMI displays source voltage, load current, compensated current, power factor, and harmonic spectrum. The controller supports several operating modes: voltage regulation, power factor correction, and reactive power control. Up to 10 units can be paralleled on the same bus to scale compensation capacity. Dry contacts provide remote alarm and run status. Modbus TCP or Ethernet IP connect to SCADA or energy management systems. The unit includes a bypass breaker and pre charge circuit for safe startup.

Application Scenarios

SVG units serve welding workshops, elevator groups in high rise buildings, VFD driven conveyor systems, pump stations, renewable energy grid connection, and commercial buildings with large HVAC chillers. Fast response compensates rapidly varying reactive loads that capacitor banks cannot follow. The unit also filters harmonics generated by VFDs and rectifiers, improving power quality. Installation parallel to the main switchboard.

In welding workshops, the SVG eliminates voltage flicker caused by sudden reactive bursts. In high rise buildings, it compensates elevator motor inrush. In VFD conveyor systems, it corrects power factor and filters harmonics. In pump stations, it reduces line current and losses. For solar farms, it regulates voltage at the point of common coupling. In commercial buildings, it eliminates utility penalties for low power factor. The unit is also used in data centers with large UPS systems and in industrial plants with many induction motors.

Compared with traditional switched capacitor banks, the SVG provides continuous stepless compensation without step transients. It does not risk resonance with system impedance, and it can absorb reactive power as well as supply it, which is useful when light load conditions cause leading power factor. The built in harmonic filtering function reduces current distortion from VFDs and rectifiers, helping the facility meet IEEE 519 limits. Multiple units can be paralleled on the same bus, with automatic load sharing, allowing capacity to grow as the load expands. The touch screen HMI and remote communication make commissioning and monitoring straightforward for electricians.

Advantages

Instant response eliminates flicker and voltage swing. Continuous control from inductive to capacitive, no step switching. Built in harmonic filtering reduces THDi. No resonance risk unlike capacitor banks. Modular units parallel for larger capacity. Touch screen and remote monitoring. Low maintenance: no capacitors to replace. Five year warranty.

Installation and Maintenance

Connect in parallel to the 0.4 kV bus through a dedicated breaker. Install current transformer on the main incoming line for load current sensing. Keep 0.8 m clearance for cooling. Commissioning includes setting target power factor, CT ratio, and response gain. Maintenance annually: clean filters, check IGBT fan, verify communication. Every two years: capacitor bank in DC link inspection, fan replacement. Keep room temperature below 40 degrees C.

Price

From $11,500 per piece including control panel, Modbus TCP, and bypass breaker. Larger capacity and IP54 enclosure are optional.