Table of Contents
ToggleProduct Overview
The KITOZER SVG static var generator is a modular voltage source converter that dynamically supplies or absorbs reactive power in under 10 milliseconds. Unlike capacitor banks that switch in finite steps, the SVG delivers continuous, stepless compensation, stabilizing voltage at the point of common coupling. KITOZER builds the 100kVAR 400V unit as a wall or floor mounted cabinet for elevators, cranes, welders, renewable energy farms, and industrial plants with fast fluctuating loads. The IGBT based topology also provides limited active harmonic filtering.
Technical Specifications
Rated 100kVAR, 400V three phase, 50Hz. Response time less than 10ms. Reactive power range from minus 100kVAR to plus 100kVAR continuously. IGBT based three phase four leg topology. Switching frequency 10kHz. Efficiency above 97 percent. Overload 120 percent for 10 minutes. Control: instantaneous reactive current detection, voltage regulation mode, power factor mode. Communication: Modbus RTU, Modbus TCP, optional Ethernet. Protection: over voltage, under voltage, over current, over temperature, IGBT fault, DC bus over voltage. Cooling: forced air with redundant fan. Cabinet IP20, floor standing. Standards IEC 61000, GB/T 20989, CE.
Application Scenarios
The SVG is used in elevator buildings, port cranes, electric arc furnaces, welders, mine hoists, wind and solar farms, and data centers where voltage flicker or fast reactive fluctuations affect the grid. It is also applied where utility requires power factor above 0.99 and where capacitor banks cannot respond fast enough.
Advantages and Features
Stepless compensation eliminates step transient. 10ms response suppresses flicker caused by cranes and welders. Modular design allows parallel expansion up to 10MVA. KITOZER offers an optional 2nd to 50th harmonic filtering mode and a touchscreen HMI showing real time reactive power, voltage, and current. The SVG is compatible with generator weak grids and supports grid code ride through requirements.
Installation and Maintenance
Install on a flat floor with 500mm clearance for cooling air. Connect via a dedicated feeder breaker sized for 1.2 times rated current. Ensure the CT is on the load side. Commissioning: set voltage reference, reactive power mode, and protection thresholds. Annual maintenance includes fan filter cleaning, IGBT DC bus capacitor inspection, and firmware update. KITOZER recommends verifying calibration of current transformers every two years.
Price
From $5,680/pc. Contact +86 13922289957 for SVG pricing.