KITOZER
KITOZER

KITOZER SVG Static Var Generator: Reactive Power Compensation Harmonic PF Correction

KITOZER SVG Static Var Generator: Reactive Power & Harmonic Compensation Guide

KITOZER SVG (Static Var Generator) is a next-generation power quality device based on IGBT voltage-source converters. It detects load reactive current in real-time and injects compensating current in anti-phase, correcting power factor to 0.99, suppressing harmonics, and balancing three-phase unbalance in under 5 milliseconds. KITOZER covers 30 kvar to 10 Mvar, low-voltage 400V and high-voltage 10kV/35kV, wall-mount and cabinet types.

1. SVG Working Principle

The main circuit is a three-phase voltage-source converter (VSC) with DC-side capacitor energy storage. IGBT switches operate at 10–20 kHz SPWM, generating a controllable AC voltage source through a coupling reactor. By adjusting the output voltage amplitude and phase relative to grid voltage, the SVG absorbs or injects reactive current continuously.

Control: d-q coordinate transformation extracts active/reactive components. The DSP controller closes the current loop at 10 kHz bandwidth. Response time: <5 ms from load step to full compensation. Range: -100% (inductive) to +100% (capacitive) rated capacity, stepless.

2. SVG vs Traditional Compensation

Item Capacitor Bank SVC (TCR+FC) SVG APF
Response time 20–40 ms 10–20 ms <5 ms <5 ms
Adjustment Stepped Nearly continuous Continuous Continuous
Harmonic handling None (resonance risk) Limited Optional (SVG-H) Yes (primary)
Three-phase unbalance No Limited Yes Yes
Resonance Prone Low None None
Efficiency >99% ~97% >97% >95%
Footprint Large Large Compact Compact
Cost Low Medium Medium-high High

3. KITOZER SVG Product Line

Model Capacity Voltage Installation Reference Price
KZ-SVG-30K 30 kvar 400V Wall/rack $2,500
KZ-SVG-50K 50 kvar 400V Wall/rack $4,000
KZ-SVG-100K 100 kvar 400V Cabinet $7,500
KZ-SVG-200K 200 kvar 400V Cabinet $14,000
KZ-SVG-300K 300 kvar 400V Cabinet $20,000
KZ-SVG-500K 500 kvar 400V Parallel cabinets $31,000
KZ-SVG-1M 1 Mvar 10 kV Cabinet group $170,000
KZ-SVG-10M 10 Mvar 35 kV Container $1,200,000

4. Sizing Calculation

Reactive power required: Q = P × (tan φ1 − tan φ2)

Where P = active power (kW), φ1 = original power factor angle, φ2 = target power factor angle.

Example: P = 1000 kW, original PF = 0.7, target PF = 0.99.

tan(arccos 0.7) = 1.020; tan(arccos 0.99) = 0.142.

Q = 1000 × (1.020 − 0.142) = 878 kvar → select 1 Mvar SVG.

Add 20% margin for future load growth: 878 × 1.2 = 1054 kvar → 1.2 Mvar.

5. Harmonic Mitigation (SVG-H)

Combined SVG+APF models (KZ-SVG-H) simultaneously compensate reactive power and filter 5th, 7th, 11th, 13th harmonics to THDi <5%. Critical for nonlinear loads: VFDs, rectifiers, UPS, LED drivers, EV chargers.

6. Three-Phase Unbalance Correction

SVG injects negative-sequence current to balance single-phase loads across three phases. Unbalance factor reduces from >10% to <2%. Essential for mixed single/three-phase loads in commercial buildings and charging stations.

7. Applications

  • Metalworking: arc furnaces, rolling mills, welders
  • Mining: hoists, conveyor VFDs
  • Renewables: PV/wind grid-tie inverters
  • EV charging: supercharger stations, bus depots
  • Data centers: UPS input power factor correction
  • Commercial: elevators, HVAC, LED lighting
  • Industrial: injection molding, cranes, pumps

8. Installation

Low-voltage SVG: floor-mounted cabinet, busbar or cable connection to LV switchgear. Wall-mount <50kvar. High-voltage: dedicated MV switchgear cubicle, protection relay, step-down transformer. Cooling: forced air ventilation, ambient -10°C to +40°C.

9. Maintenance

Annual: check cooling fans, torque connections, firmware. Every 5 years: capacitor inspection. Every 10 years: fan and DC bus capacitor replacement. Remote monitoring via Ethernet/SNMP.

10. FAQ (60 Questions)

Q1: SVG vs capacitor? A: SVG is continuous, fast, no resonance; capacitor is stepped, slow, resonance-prone.

Q2: SVG vs SVC? A: SVG uses IGBT (faster, more efficient); SVC uses thyristor TCR (slower, generates harmonics).

Q3: SVG vs APF? A: SVG primarily reactive power; APF primarily harmonics. Combined SVG-H does both.

Q4: Response time? A: <5 ms.

Q5: Power factor after compensation? A: 0.99 leading/lagging adjustable.

Q6: Efficiency? A: >97% low-voltage; >98% high-voltage.

Q7: Can SVG handle harmonic? A: SVG-H model; standard SVG does not filter harmonics.

Q8: Does SVG cause resonance? A: No, it actively dampens resonance.

Q9: Three-phase unbalance? A: Yes, corrects to <2%.

Q10: What kvar size? A: Calculate Q = P(tanφ1−tanφ2), add 20% margin.

Q11: Wall or cabinet? A: <50 kvar wall-mount; ≥50 kvar cabinet.

Q12: Parallel operation? A: Yes, up to 10 units parallel for large capacity.

Q13: Communication? A: RS485 Modbus, Ethernet, SNMP.

Q14: Display? A: 7-inch touchscreen showing PF, kvar, harmonics.

Q15: Noise? A: <65 dB (cabinet with fans).

Q16: Operating temp? A: -10 to +40°C.

Q17: Warranty? A: 2 years standard.

Q18: Certification? A: CE, ISO 9001, type test report.

Q19: Lead time? A: 15–30 days.

Q20: Can it retrofit old capacitor bank? A: Yes, replace contactor-switched capacitors with SVG.

Q21: What is thyristor switched capacitor? A: TSC, faster than contactor but still stepped.

Q22: What is TCR? A: Thyristor Controlled Reactor, part of SVC.

Q23: Why PF correction? A: Avoid utility penalty, reduce line losses, release transformer capacity.

Q24: What is power factor? A: Ratio kW/kVA; ideal = 1.0.

Q25: What causes low PF? A: Inductive loads: motors, transformers, welders.

Q26: Utility PF penalty? A: Typically PF<0.9 triggers surcharge in China.

Q27: ROI? A: 2–3 years from penalty savings and loss reduction.

Q28: What is THDi? A: Total Harmonic Distortion of current; target <5%.

Q29: Main harmonics? A: 5th (250Hz), 7th (350Hz), 11th (550Hz), 13th (650Hz).

Q30: Can SVG replace APF? A: If harmonics are moderate, SVG-H suffices; for heavy harmonics use APF.

Q31: What is step response? A: Time to reach 90% compensation after load step: <5 ms.

Q32: Oversizing? A: Add 20% for future load; undersizing leaves PF penalty.

Q33: Low voltage ride-through? A: Optional for HV applications.

Q34: Isolation transformer? A: Required for 10kV/35kV direct SVG.

Q35: Cable size? A: Based on rated current; consult KITOZER.

Q36: Protection? A: Input MCB, fuse, overcurrent/overtemp/overvoltage protection.

Q37: Redundancy? A: N+1 parallel for critical loads.

Q38: What if SVG fails? A: Bypass contactor switches load to direct feed; no outage.

Q39: Remote monitoring? A: Web/SNMP/Modbus; alarm via email/SMS.

Q40: Firmware update? A: Via Ethernet or USB.

Q41: What is DC capacitor? A: Energy storage on DC bus; lifetime 100k hours.

Q42: IGBT brand? A: Infineon/Siemens quality.

Q43: Cooling? A: Forced air; derate above 40°C.

Q44: Floor load? A: 200–500 kg/m² depending on cabinet.

Q45: Dimensions? A: 100kvar ~600×600×2000mm; 500kvar ~800×800×2200mm.

Q46: Color? A: RAL 7035 grey standard.

Q47: IP rating? A: IP20 indoor; IP54 outdoor option.

Q48: What is derating? A: Reduce capacity above 40°C ambient or 1000m altitude.

Q49: Can it work with generator? A: Yes, helps stabilize generator voltage.

Q50: PV self-consumption? A: SVG supports PV inverter PF control.

Q51: EV charger impact? A: SVG stabilizes grid at charging stations.

Q52: What is flicker? A: Voltage fluctuation from welders/arc furnaces; SVG reduces flicker.

Q53: IEEE 519 compliance? A: SVG-H helps meet IEEE 519 harmonic limits.

Q54: GB/T 14549? A: China harmonic standard; SVG-H ensures compliance.

Q55: What is dynamic reactive? A: Fast-changing reactive load (welders, elevators) needing fast compensation.

Q56: Static vs dynamic? A: Capacitor for static; SVG for dynamic loads.

Q57: Can SVG be retrofitted? A: Yes, parallel to existing bus, no downtime.

Q58: What is TCO? A: Total cost: higher capex but lower losses and penalties.

Q59: Training? A: Commissioning and operator training included.

Q60: Contact? A: Tel/WeChat +86 13922289957, +86 18520668845; WhatsApp +86 19068534140.

11. Contact

KITOZER — Guangzhou Laian Intelligent System Development Co., Ltd.
Tel/WeChat: +86 13922289957, +86 18520668845
WhatsApp: +86 19068534140
Web: https://www.gdlain.com

Shopping Cart