KITOZER Switched PDU: 32A Remote Control Sequenced

Product Overview

The KITOZER 32A sequenced switched PDU is a high-current horizontally mounted distribution unit designed for racks with multiple high-power servers and storage arrays. Twelve IEC C13 outlets plus two IEC C19 outlets cover the mix of standard and high-power devices. Each outlet is independently switched with configurable startup delay, so the operator can sequence boot-up to avoid simultaneous inrush current tripping the upstream breaker. The controller measures input voltage, current, and energy, and supports remote on, off, and reboot commands via Ethernet. A front panel per-outlet LED array shows the live state, and a manual local button allows immediate override during emergencies.

The sequenced startup is the key differentiator. After a long outage, every server and storage drive in a rack would otherwise draw locked-rotor current at the same instant, often tripping the branch breaker. By setting delays of 5 to 10 seconds between outlets, the operator staggers startup and keeps the inrush within breaker capacity. The delays are configured per outlet and can be tuned during commissioning based on the actual measured inrush of each device.

Technical Specifications

Input: single phase 200 to 240VAC, 50 or 60Hz, rated 32A, hardwired. Output: twelve IEC C13 and two IEC C19 outlets, all switched, total 32A. Per-outlet switching: latching relay, 10A for C13, 16A for C19. Startup sequence delay: 1 to 60 seconds adjustable per outlet. Metering: voltage plus or minus 1 percent, current plus or minus 1 percent, energy plus or minus 2 percent. Communication: Ethernet 10 or 100Mbps, Modbus TCP, SNMP v1, v2c, v3, HTTP, HTTPS, REST API. Functions: remote on, off, reboot, group control, scheduled power, sequence startup. Alarms: over-current, overload, via email and SNMP trap. Mechanical: 2U 19-inch rack, steel chassis, dimensions 482 x 88 x 340 mm, weight 4.2 kg. Safety: CE, RoHS. Brand: KITOZER. Warranty: 3 years.

The C19 outlets use heavier relay contacts rated 16A, suitable for high-power servers and blade chassis. The controller supports a whole-rack off command, which safely powers down all outlets in reverse sequence. A reboot macro can be assigned to a single web button, so a support engineer can cycle a hung server with two clicks. The event log records every sequence with timestamps. The unit also supports a watchdog function, where a heartbeat from the server can keep the outlet powered, and loss of heartbeat triggers an automatic reboot.

Application Scenarios

This PDU is ideal for enterprise server racks where high-power servers and storage enclosures must be brought up in a controlled order. It suits virtualization clusters, video editing workstations, broadcast equipment racks, and industrial automation cabinets that power down overnight and restart in the morning. The sequenced startup feature is particularly useful after a prolonged power outage, when every device in the rack would otherwise draw inrush current simultaneously. Managed service providers use the remote reboot function to recover unresponsive servers without dispatching staff to the site.

Broadcast studios use the PDU to control racks of playout servers, routers, and graphics workstations, bringing systems up in a defined order before airtime. Industrial automation teams use scheduled power tasks to shut down test benches at night and restart them before operators arrive. Data center operators use the watchdog function to automatically recover hung virtualization hosts without manual intervention. Research clusters use sequenced startup to bring storage online before compute, preventing boot errors. In each case, the PDU turns rack power from a manual process into an automated workflow.

Advantages and Benefits

The combination of 32A capacity, C19 outlets, and sequenced switching addresses the real-world problem of inrush tripping in high-density racks. Per-outlet group control allows maintenance staff to power down a bank of servers in one command. The remote management interface reduces operational cost for distributed sites. Energy measurement supports ongoing efficiency reporting. Latching relays minimize heat and standby power, extending relay life. The unit is designed for front-access mounting, so cabling and status checks can be done without removing the rack from service.

The watchdog function is a powerful reliability feature: if a server stops responding on the network, the PDU cycles power without human intervention. This dramatically improves uptime for lights-out sites. The reverse-sequence shutdown protects file systems by stopping compute before storage. The C19 outlets match high-power server cords, so no awkward adapters are needed. The web interface is identical to the rest of the KITOZER PDU range, so operators trained on one unit can use all others immediately. The 2U height leaves room for a cable manager above the PDU.

Installation and Maintenance Recommendations

Plan the startup sequence during design: bring up storage and network first, then application servers, then non-critical workstations. Use C19 cords for servers rated above 10A and verify the cord gauge matches the device nameplate. Connect the Earth conductor securely, and verify the input breaker rating with the site electrical engineer. Test the full startup sequence in a maintenance window before production cutover. Inspect relay contacts annually by running a built-in self-test, and check the LCD and Ethernet link during routine walk-throughs. Keep a backup of the outlet sequence configuration in the asset database so it can be restored quickly if the controller is replaced.

When setting watchdog intervals, choose a heartbeat timeout longer than the longest expected server reboot, to avoid false reboots during patching. Configure alert emails so operators know when a watchdog cycle occurs. Label each outlet with the boot order number, so on-site staff can see the sequence at a glance. Use UPS-backed power for the PDU controller itself, so it can execute a controlled shutdown when mains fail. Periodically exercise the relays once a quarter to prevent contact sticking. Keep a spare PDU on site for fast swap-out.

Price

From $395 per piece. Contact KITOZER for three-phase 63A sequenced variants.