KITOZER T2 pure copper grounding busbar is the main equipotential bonding conductor engineered for data centers, low voltage switchgear rooms, telecom exchanges, industrial control panels, and lightning protection down conductor termination systems. Manufactured from electrolytic copper with minimum 99.9 percent purity, the flat bar delivers extremely low DC resistance and high fault current carrying capacity so that lightning surge current, short circuit current, and harmonic leakage current can be discharged rapidly into the earth electrode network. The 40x4mm size is the most commonly specified cross section for cabinet-level grounding busbars in UPS rooms, server racks, and PDU enclosures. KITOZER supplies the busbar in bare copper or hot-dip tinned copper finish, with pre-drilled hole patterns on request to match customer terminal blocks, cable lugs, and exothermic welding connections.
Table of Contents
ToggleProduct Overview
The KITOZER copper grounding busbar acts as a horizontal collecting point that ties together equipment grounding conductors, cable tray bonding, rack bonding, shield grounding, SPD earth terminals, and lightning down conductors into a single low-impedance network. Because the busbar is mounted on insulators inside the cabinet or along the wall, it isolates the grounding network from accidental contact with live metalwork while keeping all grounding points at the same reference potential. The tinned option is recommended for outdoor substations, coastal plant rooms, and humid industrial environments where bare copper would develop verdigris and increase contact resistance over time. KITOZER can also cut, bend, punch, and tin the busbar in the factory according to customer drawings, reducing on-site fitting labor and ensuring consistent torque on every bolted joint.
Technical Specifications
Material: T2 electrolytic oxygen-free copper, Cu minimum 99.9 percent. Standard cross sections: 25x3mm, 25x4mm, 30x4mm, 40x4mm, 40x5mm, 50x5mm, 50x6mm, 60x6mm, 80x8mm, 100x10mm. Standard length 6 meters per bar, custom cutting available. DC resistivity: maximum 0.01721 ohm mm2 per meter at 20 degrees Celsius. Conductivity: minimum 100 percent IACS. Surface finish: bare mill finish or hot-dip tinned, tin coating thickness 8 to 12 micron. Operating temperature: minus 40 to plus 80 degrees Celsius continuously, short time fault current up to 250 degrees Celsius. Mounting: pre-drilled holes on 25mm or 50mm pitch, insulated supports included. Standards: IEC 62561 part 2, GB/T 5585, ASTM B152. Package: wooden crate with anti-corrosion paper, 500kg per pallet. KITOZER brand, 30 year design life for bare copper in dry indoor service.
Applications
The 40x4mm KITOZER copper busbar is widely used as the main grounding bus in UPS distribution cabinets, PDU enclosures, server rack sidecar grounding bars, and telecom ODF frames. Larger 60×6 and 80×8 sections are specified for data center main equipotential bonding bars, transformer neutral earthing, and lightning down conductor collector rings. In industrial plants the busbar connects motor control centers, instrument earth bars, and intrinsically safe grounding networks. In photovoltaic and wind power installations the busbar ties array frames, inverter chassis, and combiner box grounding to the main earth electrode. For lightning protection the busbar serves as the air terminal to down conductor transition point inside the roof structure, carrying the full impulse current of a direct strike safely to earth.
Advantages
Compared with galvanized steel or aluminum grounding bars, KITOZER copper busbar offers roughly six times the conductivity, lower contact resistance at bolted joints, and much better corrosion resistance when tinned. The homogeneous copper material eliminates the galvanic corrosion that occurs where steel meets copper underground. Pre-drilled hole patterns reduce drilling errors on site and improve installation speed. The hot-dip tinned surface prevents green verdigris from staining nearby paintwork and reduces maintenance cleaning. KITOZER exothermic welding and mechanical clamp compatibility means the busbar can be connected to round copper tape, copper stranded wire, and steel earth rods without transition adapters. Long length reduces the number of joints, and each joint is a potential resistance point so fewer joints means a more reliable grounding network.
Installation and Maintenance
Mount the busbar on KITOZER insulated supports at maximum 500mm spacing to avoid sag under fault current. Use copper or stainless steel bolts with Belleville spring washers to maintain torque during thermal cycling. Apply antioxidant grease to all bolted contact surfaces before assembly. When connecting stranded copper cable, use tinned copper lugs and bolted clamps rated for the same cross section. After installation, measure continuity between each equipment grounding point and the main earth test point; resistance should be below 0.1 ohm for cabinet busbars. Inspect joints every 12 months, retorque bolts after the first year, and inspect tinned surfaces for signs of tin wear in coastal or chemical environments. Record earth resistance annually and compare with baseline value to detect hidden corrosion.
Price
From $45 per meter for 40x4mm bare copper. Tinned finish from $58 per meter. Custom cut and drilled service quoted on drawing. Contact +86 13922289957 for factory price, lead time, and sample availability.