KITOZER TBB10-600 10kV Shunt Capacitor Bank 600kvar

Product Overview

The KITOZER TBB10-600 is a 10kV indoor shunt capacitor bank rated at 600kvar, installed to correct the power factor of inductive industrial loads and reduce demand charges from the utility. The bank consists of individual high-voltage self-healing capacitor units arranged in a H-bridge or star connection, with series reactor to limit inrush current and suppress harmonic resonance. A dedicated vacuum contactor or circuit breaker switches the bank, and a discharge reactor brings the residual voltage below 50V within 5 minutes after disconnection.

Technical Specifications

Rated voltage 11/root3 kV, rated frequency 50Hz, rated reactive power 600kvar three phase. Capacitor units are all-film, self-healing, rated 1.2Un continuously. Series reactor 6 percent to limit inrush and filter 5th and 7th harmonics. Discharge reactor integrated. Switching device is a 10kV vacuum contactor or VCB. Internal fuse protection per capacitor unit. Degree of protection IP20 cabinet, floor standing. Dimensions approximately 1200mm wide by 1500mm deep by 2500mm high.

Typical Applications

This 600kvar bank is typically installed at the 10kV bus of industrial plants with induction motor loads, arc furnaces, welding machines, and variable speed drives. It is also used in commercial building substations to raise the power factor above the 0.95 threshold required by the utility, avoiding penalty tariffs. The bank can be switched in steps by a power factor controller, automatically adding or removing capacitance as the plant load changes.

Key Advantages

Self-healing capacitor units clear internal dielectric faults by themselves, avoiding the catastrophic tank rupture common with older foil-type capacitors. The 6 percent series reactor prevents harmonic amplification and protects the capacitors from overload caused by 5th and 7th harmonic currents. Individual internal fuses isolate failed units without taking the whole bank offline. KITOZER factory performs a 1.3Un over-voltage test and a capacitance tolerance check on every bank before shipment.

Installation and Maintenance

Place the bank on a flat concrete plinth and connect the 10kV incoming cable through a separate feeder breaker. Keep the cabinet ventilated above 40 degrees C ambient. Before touching any capacitor unit, open the feeder breaker, close the earthing switch, and wait at least 5 minutes for the discharge reactor to bring the residual voltage below 50V. Every year, measure the capacitance of each unit and compare to the nameplate; if any unit has dropped by more than 5 percent, replace it. Tighten the busbar bolts every two years.