KITOZER
KITOZER

KITOZER Temp Humidity: 64 Point Monitoring System

Product Overview

The KITOZER 64 point temperature and humidity monitoring system is a central environmental node for data centers, server rooms, warehouses, laboratories, and clean rooms that need continuous climate visibility across many locations. Each point is a compact temperature and humidity probe connected by a single twisted pair back to the master, which samples all 64 points, computes dew point, and reports over Modbus TCP, RS485, or SNMP. The master also integrates door contacts, smoke detectors, water leak controllers, and relay outputs, making it a complete environmental monitoring hub. Alarms are raised on high temperature, low temperature, high humidity, low humidity, dew point warning, door open, and smoke, and they are pushed to the BMS, DCIM, or alarm server.

Technical Specifications

Points: up to 64 temperature and humidity probes per master, expandable with slave units. Temperature range: -20 to 60 degrees C, accuracy plus minus 0.3 degree C, resolution 0.1 degree C. Humidity range: 0 to 100 percent RH, accuracy plus minus 2 percent RH, resolution 0.1 percent RH. Dew point computed. Sampling: 10 seconds per point. Probe cable: shielded twisted pair, up to 100 meters per run. Digital IO: 16 digital inputs for door, smoke, leak controller, 8 relay outputs for alarm, fan control. Display: 7 inch color touchscreen, floor plan view. Communication: Ethernet Modbus TCP, RS485 Modbus RTU, optional SNMP, Web HMI, email and SMS alarm. Power supply: 85 to 265VAC or 24VDC. Mounting: DIN rail or wall, operating 0 to 50 degrees C. Standards: CE, 5 year warranty.

Application Scenarios

The 64 point system is deployed in data centers to monitor cold aisle, hot aisle, inlet air, and exhaust air temperatures across the floor. It is used in server rooms and network closets to keep equipment within ASHRAE limits. In warehouses and cold storage, it monitors product storage conditions. In laboratories and clean rooms, it supports GMP or ISO 14644 compliance. In museums and archives, it protects sensitive exhibits and paper. In food and beverage processing, it supports HACCP records. In pharmaceutical manufacturing, it feeds batch environmental records. The floor plan view on the touchscreen lets operators see heat hot spots at a glance.

Key Advantages

Up to 64 probes per master reduces cost per point compared with standalone sensors. Temperature and humidity accuracy of plus minus 0.3 degree C and plus minus 2 percent RH meets most commercial and industrial requirements. Dew point calculation prevents condensation events in data centers and clean rooms. Integration of digital IO and relay outputs makes the master a complete environmental hub, not just a sensor reader. Floor plan view and Web HMI give local and remote visibility. Email, SMS, and SNMP alarms reach operators fast. The 100 meter cable run supports large rooms. The 5 year warranty and DIN rail mounting simplify spares.

Installation and Maintenance Recommendations

Mount probes at the location of interest, not near walls or supply vents that bias readings. In data centers, place inlet probes at rack intake and exhaust probes at rack outlet. On commissioning, compare probes with a calibrated reference, set alarm thresholds per ASHRAE or site standard, and set dew point warning to 2 degrees C below cold aisle setpoint. Maintenance: calibrate probes annually against a reference, clean probe filters in dusty environments, and verify cable shield grounding. Trend temperature and humidity to identify cooling drift. For compliance applications, log data to a historian with timestamp integrity. Keep spare probes on site.

The 64 point system combines temperature, humidity, dew point, digital inputs, and relay outputs in one DIN rail master, reducing the number of separate protocols to integrate. The floor plan view on the touchscreen lets operators see hot spots and cold spots at a glance, and Web HMI allows remote access from the NOC. Email, SMS, and SNMP alarms reach operators before a deviation becomes a hardware failure. For compliance applications, the data logging license stores timestamped records for audit.

Ordering Information

The 64 point system is supplied as a DIN rail master with 8 probes, digital IO, and relay outputs. Additional probes are ordered individually or in packs of 10. The master includes a 7 inch color touchscreen with floor plan view, Ethernet Modbus TCP, RS485, and Web HMI. Optional packages include SNMP, email and SMS alarm gateway, BACnet IP for BMS, and a data logging license for compliance records. Probes are available with 2 meter, 5 meter, or 10 meter cable, and duct mounting probes are available for HVAC applications. Lead time is two to three weeks. KITOZER provides a floor plan template, a register list, and commissioning support. The five year warranty covers the master.

Price

From $1,480 per master including 8 probes, additional probes from $45 each. Contact the factory for floor plan software, SNMP, and alarm gateway. Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com