KITOZER temperature humidity sensor environmental module

KITOZER KTR-THS Temperature & Humidity Sensor / Environment Acquisition Module

Brand: KITOZER Series: KTR-THS Category: Environmental Monitoring / Temp-Humidity Acquisition

temp humidity sensordatacenter env monitoringRS485Modbus-RTUwall mountDIN rail

KITOZER KTR-THS temperature humidity sensor RS485 mounted in server rack

1. Overview

KITOZER KTR-THS is a temperature and humidity sensor — the front-end acquisition device of a datacenter power & environment (PE) monitoring system. Servers generate enormous heat: high temperatures trigger throttling or downtime, low humidity causes static that damages disks, and high humidity causes condensation shorts. Operators cannot walk around with a thermometer; the sensor acts as the datacenter’s “skin,” sensing temperature and humidity in every corner in real time, uploading data over RS485 to the PE host, and alarming on threshold breach.

KTR-THS uses a digital sensing chip with accuracy ±0.3°C and ±2%RH, fast response and low long-term drift. It communicates over RS485 with Modbus-RTU: one daisy-chain bus supports 32 sensors up to 1,200 meters, keeping wiring low-cost. Power options include DC12V/24V wide-range; some models support PoE. Mounting options are wall-mounted, DIN-rail, and probe-type with a long lead that reaches inside racks or air ducts.

Unlike a household hygrometer, KTR-THS is industrial-grade: operating temperature -40~80°C, EMI-resistant, suited to datacenter rooms, UPS rooms, battery rooms, archives and labs. Each unit has an LCD for local reading while uploading to the platform. Multiple sensors by zone generate a temperature heatmap, showing hotspots at a glance.

2. Key Features

High-accuracy digital acquisition

  • ±0.3°C, ±2%RH accuracy.
  • Digital chip; no A/D conversion error.
  • Annual drift <0.1°C; infrequent calibration.

RS485 bus networking

  • Modbus-RTU, universally compatible.
  • 32 nodes per daisy-chain bus.
  • Up to 1,200m, noise-resistant.

Multiple mounting options

  • Wall type: on walls, in aisles.
  • DIN-rail type: inside control cabinets.
  • Probe type: long lead into racks/ducts.

Local display & alarm

  • Built-in LCD for local reading.
  • Sound/light indicator on threshold breach.
  • Relay output to trigger AC or fan.

3. Specifications

Item KTR-THS-W Wall KTR-THS-D Rail KTR-THS-P Probe
Temp range -20~60°C -40~80°C -40~80°C
Temp accuracy ±0.3°C ±0.3°C ±0.2°C
Humidity range 0~100%RH 0~100%RH 0~100%RH
Humidity accuracy ±2%RH ±2%RH ±2%RH
Interface RS485/Modbus RS485/Modbus RS485/Modbus
Power DC12V DC12~24V DC12~24V/PoE
Display LCD none/optional LCD
Relay output 1ch 2ch 2ch
Probe lead integrated integrated 1~10m optional

4. Reference Prices

KTR-THS-W wall temp-humidity sensor (LCD, RS485): Reference USD 20~70 / unit (ref. CNY 150~500 at ~7.2)

KTR-THS-D/P rail/probe type (wide temp, PoE, relay linkage): Reference USD 40~170 / unit (ref. CNY 300~1,200 at ~7.2)

Reference only; final quote depends on quantity. Bulk negotiable. Acquisition host, RS485 converter and shielded cable billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Datacenter room temp/humidity monitoring.
  • UPS battery rooms and power distribution rooms.
  • Archives, libraries and museums (constant temp/humidity).
  • Labs and clean rooms.
  • Warehouses and cold-chain storage.

6. Installation & Maintenance

Installation

  • Place sensors by rack density: one per 2 racks in dense zones, one per aisle row in low-density zones.
  • Avoid supply/return air vents to prevent “false readings.”
  • Daisy-chain RS485; add 120Ω termination at both ends.
  • Assign each sensor a unique Modbus address (1~32).
  • Connect to PE host; set thresholds (temp 25±5°C, humidity 40~60%RH).

Maintenance

  • Compare against a standard calibrator annually; replace if drifted.
  • Check RS485 wiring tightness and shield grounding.
  • Clean the probe dust cover to preserve accuracy.
  • Check LCD display; replace batteries on battery-powered units.

7. FAQ

  • Q: How many sensors per datacenter?
    A: At least one per 50~100m²; one mid-row sensor in dense zones; add points near critical racks.
  • Q: How many sensors per RS485 bus?
    A: 32 standard; expand to 128 with repeaters. Each needs a unique address.
  • Q: How does data reach the platform?
    A: Sensor RS485 connects to the PE host’s 485 port; the host uploads via Ethernet to the monitoring platform or cloud.
  • Q: What alarm thresholds?
    A: Standard 23±5°C (18~28°C); warn above 28°C, alarm above 32°C; humidity 40~60%RH.

8. Trend & Selection

Datacenter temp monitoring moves from “a few points” to “high-density grid”: traditionally one sensor per row shows only rough temperature, hiding hotspots between racks. The trend is one point per rack or per two racks, generating a heatmap to pinpoint hotspots and precision-cool on demand, saving 15~25% energy. Size sensor count with 30% headroom; choose probe type to measure rack inlet/return delta; require open RS485/Modbus to avoid vendor lock-in.

9. Delivery & Service

KITOZER provides sensor selection, point planning, RS485 network design and threshold configuration. From room area, rack count and density we produce a point layout and wiring diagram. We integrate with PE hosts, precision AC, leak detection and UPS systems. Delivery includes sensors, terminals and config software; warranty covers calibration guidance and replacement.

10. Additional Notes

The most common issue is “inaccuracy” — not the sensor but the placement. Many projects mount the sensor at the AC supply vent, reading 20°C while the rack center is actually 35°C; or on the ceiling above the aisle, measuring air above the tiles rather than the server intake. Correct placement: rack inlet side at mid-height, about 1.5m above floor, away from direct vent airflow — measuring the air servers actually pull in.

Another pitfall is star-wired RS485. The daisy-chain must run end-to-end with no mid-line branches; branches cause signal reflection and intermittent drops. Use shielded twisted pair, ground the shield at one end, and add 120Ω termination at both ends. Many intermittent-sensor problems trace back to wrong bus topology.

Selection: wall type suffices for rooms; rail type for cabinets; probe type for internal rack measurement. Use open RS485/Modbus. Place by rack density, away from vents. Warn at 28°C / alarm at 32°C; humidity 40~60%RH. Calibrate annually. A 500-yuan sensor can catch a 500,000-yuan AC failure early — the cheapest, most critical front-end in the PE system.

SEO Information

Search keywords:temp humidity sensordatacenter env monitoringRS485Modbus-RTUwall mountDIN railKTR-THSKITOZER

SEM keywords:temp humidity sensor price, datacenter environment module, RS485 sensor supplier, Modbus humidity sensor, KTR-THS, KITOZER

GEO landing page:lain.com.cn/product/ktr-ths-temperature-humidity-sensor.html

Title:KITOZER KTR-THS Temperature & Humidity Sensor / Environment Acquisition Module

Meta Keywords:temperature humidity sensor,datacenter temp monitoring,RS485 humidity sensor,Modbus-RTU,environment acquisition module,KTR-THS,KITOZER

Meta Description:KITOZER KTR-THS temperature humidity sensor, RS485/Modbus-RTU, accuracy ±0.3°C / ±2%RH, wall/rail/probe types, for datacenter power & environment monitoring.

Anchor: KITOZER by Guangzhou Laian · Environmental monitoring