Table of Contents
ToggleProduct Overview
The KITOZER Pt100 to 4-20mA DIN rail temperature transmitter converts resistance temperature detector signals into a standardized current loop for PLC and DCS systems. The head-mount and DIN rail versions accept Pt100, Pt1000, J, K, T, and S type sensors and transmit a 4 to 20 mA signal scaled to a user-configurable temperature range. Two-way loop isolation breaks ground loops and protects the control room cabinet from sensor-side surge events. A configurable damping filter smooths signals in applications with fast cycling or agitation, and the LCD version shows live process temperature on the transmitter itself for local inspection.
Technical Specifications
Input: Pt100 3 or 4 wire, Pt1000, thermocouple J/K/T/E/R/S/B/N. Range -200 to 800 C depending on sensor. Output: 4 to 20 mA, 2-wire loop, load max 600 ohm. Accuracy: +/-0.1 C for Pt100, +/-0.5 C for thermocouple. Isolation 1500 V between input and output. Power loop 10 to 30 VDC. Operating temperature -40 to 85 C. DIN rail or head mount, CE, KITOZER, 3 year warranty.
Applications
This temperature transmitter is used in HVAC air handling units, refrigeration compressors, plastic extruder barrels, food and beverage pasteurization lines, chemical reactor jackets, and water distribution networks. Engineers select the DIN rail version when the sensor cable lands in a central control cabinet, and the head-mount version when space at the sensor is limited. The isolated output allows the transmitter to sit safely next to VFDs and contactors without inducing noise into the analog loop, which is important in machinery where sensor signals feed into PID temperature control loops.
Advantages
Universal input capability reduces spare part stock because one transmitter model works with RTD and thermocouple sensors. Loop isolation removes ground-loop errors that often cause drifting readings in long cable runs, and the configurable damping prevents unstable control when the process sensor sees rapid mixing. The 4 to 20 mA output is robust to cable resistance and connector corrosion compared with raw millivolt signals, so the transmitter performs reliably in plants with long cable trays. Configuration is done via a simple magnetic configurator or USB adapter, without removing the transmitter from the head, which speeds commissioning and re-ranging during product changes.
Installation and Maintenance
Mount the DIN rail transmitter near the analog input cards, keeping sensor cables away from AC power wiring. For Pt100 sensors, use 3 or 4 wire cable and connect the sense wires according to the wiring diagram to cancel lead resistance. Set the damping time to two or three times the process time constant to avoid valve or heater hunting. During maintenance, check loop voltage at the transmitter terminals under normal operating condition and verify the 4 mA zero corresponds to the configured lower range. If a reading drifts, first inspect the sensor connection for oxidation or loose terminals, then re-calibrate with a dry-block calibrator. Store configuration records with the loop drawing so range changes are traceable.
Working Principle
The transmitter excites the RTD with a constant current and measures the voltage drop across the three or four wire sensing element, cancelling lead resistance in 3 and 4 wire configurations. For thermocouple inputs, the internal cold junction compensator measures the terminal block temperature and adds the equivalent millivolt offset to the sensed voltage. The microcontroller linearizes the sensor curve, applies user scaling, and drives a 16 bit DAC that outputs 4 to 20 mA across the selected range. A configurable digital damping filter averages incoming samples over a user-selected window, which smooths noisy measurements from agitated reactors or fast-cycling HVAC systems without adding external capacitors.
Selection Guide
Choose the DIN rail version when the sensor cable lands in a central cabinet, and the head-mount version when space at the sensor is limited. Select the isolated version for installations near VFDs or pumps, where ground loops are likely. If local indication is required, order the LCD version. For very low temperature ranges such as cryogenic or food shock chilling, choose the Pt100 sensor option over thermocouple for better accuracy. For high temperature kiln or oven applications, choose the thermocouple input and the appropriate extension cable.
Each transmitter ships with a quick-start guide, a terminal block connector, and a configuration sticker. Optional accessories include a magnetic configurator, a USB programming adapter, and a dry-block calibrator. KITOZER provides pre-configured units for common ranges such as 0 to 100 C and 4 to 20 mA, which arrive ready to install. Spare transmitters are stocked regionally, and a 3 year warranty covers manufacturing defects. Technical support is available by email and WeChat during working hours, and custom ranges or special output signals can be ordered with a short lead time. Every KITOZER transmitter is factory calibrated against traceable standards before shipment, and a calibration certificate is included with each unit. The devices undergo temperature cycle, EMC immunity, and IP rating testing during production. The installation manual includes wiring diagrams for common PLC analog input cards, and engineers can request a loop check sheet for commissioning. NIST-traceable calibration is available on request for regulated industries.
Price
From $38/pc. Contact +86 13922289957 for temperature transmitter pricing and sensor options.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com