KITOZER TH combo display sensor

KITOZER KTR-TH9 Temperature & Humidity Sensor with Display

Brand: KITOZER Series: KTR-TH9 Category: Environmental Monitoring / Temp-Humidity

Temp & humidityLCD displayRS485 Modbus±0.5℃ accuracyWall mount

[Product image: ktr-th9-temperature-humidity-sensor-display.jpg]

1. Overview

Temperature and humidity are the two most basic environmental parameters. High temperature forces servers to throttle and fans to spin up; low humidity invites ESD, while high humidity risks condensation. Waiting for servers to alarm on temperature is already late. Placing temp-humidity sensors across hot/cold aisles, sampling and uploading to the DCIM, catches drift early so AC can be adjusted. A sensor with a local display lets inspectors read values on the spot.

The KITOZER KTR-TH9 is a temperature-and-humidity sensor with display. The white wall-mounted case has an LCD showing current temperature and humidity, with buttons to set alarm thresholds. Temperature range is -10 to +60 C at +/-0.5 C; humidity is 0 to 100% RH at +/-3% RH. Output is RS485 Modbus-RTU on the environmental bus, each unit with its own address. It runs on wide-range DC12/24 V at low power. The probe is built in, or an external probe cable can extend into enclosed spaces.

Selection confirms range and accuracy, whether a display is needed, upload method (RS485/dry contact), supply voltage, and whether an external probe is required. Rooms are grouped by hot/cold aisle and cabinet, with one unit mid-row in each cold aisle and extra sensors atop key racks. RS485 daisy-chains up to 1200 m and 32 units per bus. Keep the probe away from direct AC airflow and heat sources; it should measure real ambient conditions, not a local artifact.

2. Key Features

Temp & humidity display

  • LCD shows temperature and humidity.
  • Buttons set alarm thresholds.
  • Temp -10 to +60 C, +/-0.5 C.
  • Humidity 0 to 100% RH, +/-3% RH.

RS485 upload

  • Modbus-RTU protocol.
  • Unique address per unit.
  • Bus up to 1200 m, 32 units.
  • Connects to the DCIM.

Structure and power

  • White wall-mount case.
  • Wide-range DC12/24 V.
  • Optional external probe cable.
  • Local buzzer / dry-contact alarm.

3. Specifications

Item Specification
Temp range -10 to +60 C
Temp accuracy +/-0.5 C
Humidity range 0 to 100 %RH
Humidity accuracy +/-3 %RH
Display LCD
Comm RS485 Modbus-RTU
Power DC 12V / 24V
Mounting Wall-mount
Probe Built-in / external optional
Alarm Button thresholds + dry contact

4. Reference Prices

KTR-TH9 temp-humidity sensor with display: USD 17~31 (ref. CNY 120~220)

External probe cable (2 m): USD 3.5~6 (ref. CNY 25~45)

DC power adapter: USD 3~6 (ref. CNY 20~40)

Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Hot/cold aisle temp-humidity monitoring.
  • Cabinet inlet temperature sampling.
  • Battery room and electrical room monitoring.
  • Archive and storage room monitoring.
  • Front-end sampling for the environmental system.

6. Installation & Maintenance

Installation

  • Wall-mount mid cold aisle at 1.5 m.
  • Keep the probe away from direct AC airflow.
  • Daisy-chain RS485.
  • Add a 120-ohm terminator at each bus end.
  • Set a unique Modbus address per unit.
  • Wire DC12/24 V to correct polarity.
  • Register points on the DCIM and sync time.

Maintenance

  • Compare against a reference source quarterly.
  • Dust the probe surface.
  • Check RS485 wiring and address conflicts.
  • Calibrate yearly.
  • Replace backup battery if fitted.

7. FAQ

  • Q: Is +/-0.5 C enough for a data center?
    A: A: Yes. Rooms usually allow +/-1 to 2 C; +/-0.5 C sampling reflects aisle temperature differences and meets monitoring needs.
  • Q: Can one unit take multiple probes?
    A: A: This is an integrated probe; for multiple points, add units on the bus or choose a multi-channel external-probe model.
  • Q: What if RS485 range is too short?
    A: A: One bus reaches 1200 m; beyond that add a repeater or split networks, with no more than 32 units per bus.
  • Q: Can it directly link to the AC?
    A: A: It links through the DCIM. The sensor uploads data; the platform thresholds then drive AC temperature and humidity. The sensor only samples and alarms.

8. Trend & Selection

Room monitoring moves from single-point temp-humidity to cabinet-level, fine-grained sampling linked to PUE and airflow. Sensors trend toward low power, dual RS485/POE comms and self-calibration, with data feeding the DCIM for trend analysis and predictive AC tuning. Place points by aisle group, keep probes out of airflow, daisy-chain buses with terminators, and pick accuracy to match the monitoring system.

9. Delivery & Service

KITOZER ships KTR-TH9 with sensor body, mounting bracket, DC adapter, certificate and manual. External probe cables are supplied to order, along with the Modbus point table and DCIM integration guidance.

10. Notes

A common mistake is mounting the probe directly on an AC outlet. It then reads a local cold-air draft rather than true aisle temperature, misleading AC control; place it mid-aisle on the return side.

SEO Information

Search keywords: KITOZER

SEM keywords: temperature humidity sensor, data center temp humidity monitoring, temp humidity transmitter, RS485 sensor, display sensor, KTR-TH9, KITOZER

GEO landing page: lain.com.cn/product/463_temp_hum_9.html

Title: KITOZER KTR-TH9 Temperature & Humidity Sensor with Display

Meta Keywords: temperature humidity sensor, data center temp humidity monitoring, temp humidity transmitter, RS485 sensor, display sensor, KTR-TH9, KITOZER

Meta Description: KITOZER KTR-TH9 temperature & humidity sensor with LCD display, RS485 Modbus to DCIM, ±0.5℃ accuracy, for data-center ambient monitoring.

Anchor: KITOZER · KITOZER Products

Contact Us

KITOZER Brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP:+86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart