The KITOZER thermal management system keeps lithium battery cells within a narrow temperature band, extending cycle life and preventing thermal runaway. Available as forced-air air conditioning or liquid cooling, the system is built into the battery cabinet or container and controlled by a dedicated controller that reads cell temperatures from the BMS. It is essential for high-energy-density storage operating in hot or cold climates.
Table of Contents
ToggleProduct Overview
The KITOZER thermal system includes a sealed air handling unit, a DC or AC inverter-driven compressor, a coolant loop for liquid versions, and redundant fans. It maintains cabinet inlet air at 25 to 35 degrees Celsius regardless of ambient, and heats in winter when cell temperature drops below 5 degrees. The controller communicates with the BMS over CAN and adjusts cooling capacity to actual load, saving energy compared with fixed-speed units.
Technical Specifications
Cooling capacity 3kW to 12kW per cabinet, 30kW to 120kW per container. Refrigerant R410A or R32. Operating ambient -30 to +55 degrees Celsius. Temperature control range 20 to 35 degrees Celsius, stability plus or minus 2 degrees. Humidity control 40 to 60 percent RH. Power supply 230V single phase for small units, 400V three phase for containers. Communication CAN to BMS, Modbus TCP to EMS. Protection IP54 outdoor. Redundant compressor option. Dimensions depend on cooling capacity. KITOZER brand, 3-year warranty on refrigeration parts.
Applications
This thermal system is used in outdoor battery cabinets for C&I storage, battery containers for grid services, telecom base station batteries, and off-grid microgrids in desert, tropical, or cold climates. It is also used in data center UPS battery rooms where high ambient heat would shorten battery life.
Advantages and Features
Variable-speed inverter compressors match cooling to real heat load, reducing parasitic energy use by up to 30 percent compared with on-off systems. Active cooling and heating allow battery operation across a wide ambient range, preserving rated capacity. Uniform air distribution keeps cell-to-cell temperature difference below 3 degrees, the key factor for long battery life. Redundant cooling loops ensure a fault in one loop does not overheat the battery. The unit supports remote monitoring and alarm via the site EMS. Condensate management and air filtration protect cabinet electronics.
Installation and Maintenance
Mount the air handling unit on the side or top of the cabinet with clear air intake and discharge paths, away from direct sun. Connect the refrigerant lines by a certified HVAC technician and pressure-test before startup. Set the BMS temperature setpoints and interlocks during commissioning. Maintenance quarterly includes cleaning the air filter and checking refrigerant sight glass, annually includes checking condenser coils, compressor oil level, and electrical terminals. Keep a spare filter and contactor on site. In dusty environments, shorten filter service intervals to monthly.
Price
From $1,680/cabinet cooling unit. Contact +86 13922289957 for container-level thermal design and heat load calculation.