Table of Contents
ToggleProduct Overview
KITOZER tinned copper grounding busbar 100x10mm is engineered as the main horizontal collector in substation, switchgear, industrial plant, and data center grounding grids. Manufactured from high-electrical-conductivity copper grade Cu-ETP with electro-tin plating 8 to 12 microns, the busbar provides stable low-impedance equipotential bonding between vertical grounding electrodes, cable shields, equipment enclosures, and metal structures. The 100mm width and 10mm thickness carry fault currents of several kiloamperes without overheating, while the tin coating prevents oxidation and green patina formation over decades of buried or indoor service. KITOZER supplies the bar in cut lengths, pre-drilled hole patterns, or full coils depending on project design, and can stamp customer connection layouts per single-line diagrams. The solid rectangular section also acts as an equipotential reference plane that keeps touch voltage below safe limits during both power frequency faults and lightning surge events.
Technical Specifications
Material: Cu-ETP oxygen-free copper, conductivity not less than 99.9% IACS. Cross section 100mm by 10mm, standard length 6m per bar or coil on request. Surface finish: electro-tin plated 8-12 microns, matte silver. Hole pattern: M10/M12/M14 drilled to project drawing, or plain bar. Rated short-time current: 25 kA for 1 second under IEC 60949 steady heating reference. DC resistance at 20C: not more than 0.022 milliohm per meter. Operating temperature: minus 40C to plus 105C continuous. Compatibility: brazed, exothermic welded, or bolted clamp connection to copper tape, copper-clad steel rod, and cable lug. Certifications: ISO 9001, RoHS, CE marking. Brand: KITOZER. Warranty: 25 years for buried copper, 10 years for indoor. Mechanical strength allows vehicle impact in outdoor switchyards without deformation.
Application Scenarios
This busbar is widely used as the main earth grid collector in 110kV to 500kV substations, as the low-voltage main earthing bar in switchgear rooms, as the bonding bar in data center raised-floor and rooftop PDUs, and as the equipotential ring in explosion-proof zones of petrochemical plants. It also serves as the neutral-to-earth connection point in TT and TN-S systems, as the reference bar for surge protector counterpoises, and as the rail supporting grounding cable trays in industrial plants. Typical installations include transmission and distribution substations, wind farm base stations, solar inverter rooms, telecommunications exchange buildings, water treatment pump stations, hospital critical care electrical rooms, railway traction substations, and large commercial building main switchrooms. In data centers it forms the ring bus around the raised floor, connecting every rack, PDU, and cable tray to a single low-impedance reference.
Advantages and Features
KITOZER tinned copper busbar offers several engineering advantages. First, the high conductivity copper minimizes ground potential rise during lightning or fault events, keeping touch and step voltages within safety limits. Second, the tin plating prevents the green oxide layer that otherwise increases contact resistance at bolted joints over time. Third, the bar accepts exothermic welded connections, which are permanent, maintenance-free, and approved by most utility standards. Fourth, KITOZER offers cut-to-length and pre-drilled service, reducing field fabrication time and labor cost on site. Fifth, the material is fully recyclable, supporting green building and LEED documentation. Finally, the rigid rectangular section does not sag between supports and tolerates crane impact in outdoor switchyards. The tin coating also provides a clear visual inspection surface: joints remain silver and free of oxide for decades.
Installation and Maintenance Recommendations
During installation, clean the bar surface with a wire brush before clamping or welding, apply antioxidant compound to bolted joints, and torque M12 bolts to 25 Nm per IEC 62561. Maintain support spacing not more than 800mm horizontally and 600mm vertically to avoid vibration fatigue. For buried sections, wrap the bar with bitumen tape or place it in backfill rich in conductive clay; avoid contact with lime or corrosive cinder. During annual inspection, measure joint resistance with a micro-ohmmeter, inspect tin plating for scratches, and re-torque bolts if any looseness is detected. Record grounding loop resistance and compare with baseline reading. If resistance rises above project threshold, add grounding enhancement agent or install additional electrodes. KITOZER provides installation training, exothermic welding powder kits, and test report templates. For indoor bars, keep the surface painted with anti-oxidation lacquer to delay tarnish.
Quality Assurance and Ordering Information
Every batch of KITOZER copper busbar is supplied with mill test report covering conductivity, tensile strength, tin coating thickness, and dimensional tolerance. Each bar carries a laser-etched batch number for traceability. Standard lead time is 7 to 15 days depending on length and hole pattern. Custom stamping, silver plating, or insulation sleeving is available on request. KITOZER also supplies matching copper clamps, exothermic weld molds, and testing instruments as a package. For project bidding, KITOZER can provide IEC and IEEE compliance certificates, third-party test reports from CNAS labs, and installation guidance on site. Samples are available within 3 days for engineering evaluation.
Price
From $88 per meter. Contact +86 13922289957 for bulk quotation, project drawing review, and factory lead time.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com