KITOZER 10kVA three-phase online double conversion tower UPS is a floor-standing critical power system for small and medium data centers, industrial process rooms, and enterprise IT closets. The unit continuously converts utility AC to DC through an IGBT PFC rectifier and regenerates pure sinusoidal AC through a high-frequency inverter, isolating connected loads from surges, sags, swells, harmonics, and frequency drift. With output power factor 0.9, the system delivers 9kW of real power to modern server and storage loads.
Table of Contents
ToggleProduct Overview
The 10kVA tower cabinet houses rectifier, inverter, battery charger, bypass circuitry, and a generous internal VRLA battery bank in a single compact enclosure. A 7-inch color touchscreen on the front door displays phase voltages, currents, load bar, battery state of charge, and event history. The unit includes a built-in manual maintenance bypass, allowing service technicians to isolate the UPS electronics while the critical load remains powered through the bypass line. Communication options include Modbus TCP, SNMP, Web HMI, USB, RS232, and dry contact relay outputs, enabling integration with building management, DCIM, and remote monitoring platforms.
Technical Specifications
Rated 10kVA / 9kW. Input 3P+N+PE 380/400VAC, range 320-480VAC, PFC >0.99, input THDi <3%. Output 3P+N+PE 380/400VAC, line-to-neutral 220/230VAC, regulation +/-1%, THDv <2% linear load. Inverter efficiency 95%, ECO mode 98%. Internal VRLA 12V 9Ah x 30, runtime 8-12 min full load. External battery cabinets support runtime up to 4 hours. Parallel N+1 up to 4 units. Operating temperature 0-40C, noise <60dBA. Dimensions 600 x 800 x 1400mm, weight 320kg. CE, ISO 9001 certified. KITOZER brand, 3 year warranty.
Application Scenarios
This tower UPS is commonly specified for medium enterprise server rooms, manufacturing execution systems, hospital imaging departments, broadcast transmission racks, and government data closets. When paired with external battery cabinets, it bridges the 10-30 second gap between utility failure and generator pickup. Parallel N+1 configurations are used in healthcare IT, financial back offices, and cloud point-of-presence racks where a single point of failure is unacceptable.
Advantages and Features
Three-phase input and output match standard data center distribution. Low input THDi eliminates upstream harmonic filters. High efficiency reduces cooling and electricity cost. Built-in maintenance bypass enables live service. Parallel N+1 supports modular growth. The color touchscreen and comprehensive communication protocol set simplify commissioning and remote monitoring.
Installation and Maintenance Advice
Verify floor load rating and vibration isolation. Use dedicated input and output breakers per local code. Confirm phase rotation before energizing. Size external battery cables for less than 1% voltage drop. Configure NTP and alarm recipients during commissioning. Inspect DC terminals annually for thermal growth. Replace batteries every 4-5 years.
Price
From $6,200/pc. Contact +86 13922289957 for 10kVA tower UPS pricing, external battery cabinet sizing, and parallel redundancy options.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com