KITOZER Tower UPS 30kVA Small Data Center Three Phase

Product Overview

The KITOZER Tower UPS 30kVA is a high-capacity online system delivering 30kW at power factor 1.0 for small data centers, enterprise IT rooms, and industrial critical loads. Three-phase input and output, combined with transformer-less high-frequency topology, achieve up to 96 percent efficiency while keeping cabinet size compact. The unit supports parallel operation up to 8 units for N+X redundancy.

Built for 24/7 mission-critical operation, the KITOZER unit uses transformer-less high-frequency topology with IGBT inverter technology and digital signal processor control for precise output voltage and frequency regulation. The wide input voltage window allows the UPS to ride through deep sags and swells without switching to battery, extending battery life and reducing cycling. Input power factor correction greater than 0.99 and total harmonic distortion less than 3 percent help the site comply with IEEE 519 requirements and avoid utility penalty charges. The unit is CE certified and complies with IEC 62040 safety and EMC standards for global deployment.

Intelligent battery management performs periodic self-tests every 30 days, monitors cell voltage, charge current, and ambient temperature, and compensates charge voltage to maximize battery service life. The front panel color LCD displays real-time input voltage, output voltage, load percentage, battery capacity, temperature, and active alarms, rotating automatically for rack or tower orientation. Optional SNMP and Modbus TCP integration fits DCIM, building management, and NMS platforms for remote alarm email, scheduled shutdown, and historical logging. Three-year standard warranty with optional extended coverage available from KITOZER factory.

Technical Specifications

Input 380, 400, or 415V three phase, range 304 to 478VAC. Output 380, 400, or 415V three phase, PF 1.0, online efficiency 96 percent. Parallel up to 8 units. Dimensions 800 by 1000 by 1900 mm, weight 520 kg. IP20 cabinet.

Input power factor greater than 0.99, total harmonic distortion less than 3 percent, online efficiency optimized for low operating cost and reduced cooling load. Output voltage regulation within plus or minus 1 percent ensures clean power for sensitive IT loads and industrial control equipment. Overload rating supports motor inrush currents and transient events. Operating temperature 0 to 40 degrees Celsius, relative humidity 5 to 95 percent non-condensing. Event log stores up to 512 records for troubleshooting and compliance reporting. Color LCD with backlight and intuitive menu navigation for daily operation.

Application Scenarios

Deployments include small data centers, cloud edge nodes, hospital clinical systems, manufacturing execution systems, railway signaling, and large corporate offices. The N+X parallel option is used when uptime SLAs require redundant power.

Additional use cases include government back-office systems, media editing workstations, security operations centers, university computer labs, and small manufacturing work cells. The wide input voltage range allows deployment in regions with unstable grid voltage where line-interactive units would constantly switch to battery. The pure sine-wave output is safe for active PFC power supplies found in modern servers, storage arrays, and high-end network appliances. External battery cabinets are chosen when generator start-up time is long or not available, ensuring orderly shutdown of virtualization clusters and critical workloads.

Key Advantages

PF 1.0 delivers full 30kW output from a 30kVA frame. 96 percent efficiency reduces energy cost. Parallel up to 8 units enables modular growth.

Built-in surge and EMI filtering protects connected equipment from lightning transients and conducted noise. Compact design saves valuable rack or floor space in data center and IT room environments. Hot-swappable batteries allow replacement without powering down the load, reducing service time to minutes. The optional SNMP card integrates with existing DCIM and BMS platforms without additional hardware cost. Comprehensive event log and waveform capture simplify troubleshooting for maintenance teams and reduce mean time to repair.

Installation and Maintenance Advice

Install on reinforced concrete floor. Coordinate upstream breaker with UPS short-circuit rating. For parallel systems, use dedicated paralleling cables.

Keep ambient temperature between 20 and 25 degrees Celsius for maximum battery life and optimal UPS performance. Download the KITOZER PowerShut software for graceful shutdown of connected servers during extended outages. Perform a full discharge test every 6 months to verify runtime and battery health. Recharge batteries for 8 hours after installation or replacement. Update firmware via USB in maintenance window and keep the event log exported before upgrades. Keep spare fans and fuses on site for fast replacement. Label bypass positions and emergency stop buttons clearly for maintenance teams.

Price

From $14,500 per unit. Custom configurations and bulk orders are welcome. Contact KITOZER engineering team for detailed quotation, factory lead time, and shipping options worldwide. Battery cabinet and parallel kit quoted separately.

KITOZER provides comprehensive technical support including pre-sales consultation, system design guidance, factory training, and on-site commissioning assistance. Spare parts inventory is maintained for fast shipment worldwide. Extended warranty plans are available for mission-critical installations. Contact KITOZER engineering team for custom configurations, high-altitude derating, and specific application requirements.