KITOZER
KITOZER

KITOZER Transformer Solution

Table of Contents

1. System Overview

The KITOZER transformer system is a core power distribution supporting device developed based on the electromagnetic induction principle. Acting as a “bridge” between the primary and secondary sides of power systems, it precisely converts high-voltage large currents and high voltages into standard low-voltage small currents (5A/1A) and low voltages (100V). It delivers accurate signals for measurement, metering, relay protection and signal transmission, while realizing electrical isolation between high and low voltages to protect personnel and equipment safety.

The system is fully compatible with low-voltage (≤1kV), medium-voltage (1kV–35kV) and high-voltage (≥35kV) scenarios. Featuring high precision, outstanding stability, superior anti-interference performance and wide adaptability, it meets measurement, metering and protection requirements across industrial power distribution, smart grids, new energy, rail transit, construction engineering and other sectors, serving as a critical foundational device for safe and stable operation of power distribution systems.

image

KITOZER Transformer

2. System Composition

The KITOZER transformer system consists of five core modules: core sensing unit, insulation protection unit, terminal wiring unit, sealing structure unit and auxiliary fitting unit. Coordinated operation of all modules ensures accurate, safe and stable system performance.

  • Core Sensing Unit: Comprises iron core (silicon steel sheet / amorphous alloy), primary winding and secondary winding. It is the core component for current/voltage conversion and determines measurement accuracy and transmission stability.
  • Insulation Protection Unit: Adopts epoxy resin casting, insulating oil, SF6 gas and other insulating materials, delivering excellent insulation strength, moisture resistance and anti-pollution flashover performance for harsh operating environments.
  • Terminal Wiring Unit: Dedicated terminals for primary side (P1/P2, A/X) and secondary side (S1/S2, a/n) made of rust-proof conductive materials, ensuring firm wiring and reliable conductivity to facilitate on-site installation and commissioning.
  • Sealing Structure Unit: Full-sealed design equipped with sealing rings and sealant to block moisture and dust intrusion, extending equipment service life for outdoor, humid and heavily polluted working conditions.
  • Auxiliary Fitting Unit: Includes mounting brackets, fixing bolts, secondary short-circuit wires, grounding terminals, dust covers and other accessories. Compatible with indoor/outdoor, wall-mounted/cabinet-mounted installation to simplify construction procedures.

3. System Classification

image

Transformer Structure & Material Diagram

KITOZER transformers are categorized across four dimensions: function, voltage level, structural form and installation method, covering all application scenarios with clear classification for convenient model selection.

3.1 Classification by Function

  • Current Transformer (CT): Converts large primary currents into standard small secondary currents (5A/1A) for current measurement, electric energy metering, overcurrent/short-circuit protection. Subdivided into measuring class, protection class and zero-sequence protection class.
  • Voltage Transformer (PT/VT): Converts high primary voltages into standard low secondary voltages (100V) for voltage measurement, electric energy metering, overvoltage/undervoltage protection and insulation monitoring.
  • Combined Transformer: Integrates current and voltage transformer functions in an all-in-one design to save installation space, ideal for outdoor power distribution and small substations.
  • Zero-sequence Transformer: Specially designed to detect zero-sequence currents for ground fault protection and leakage monitoring, widely applied in low-voltage power distribution and high-voltage system ground fault protection.

3.2 Classification by Voltage Level

  • Low-voltage Transformer (≤1kV): Compatible with 0.4kV and 0.66kV low-voltage power distribution systems. Compact size and easy installation, including split-core, through-core and busbar-mounted structures.
  • Medium-voltage Transformer (1kV–35kV): Designed for 6kV, 10kV and 35kV medium-voltage power distribution systems, adopting epoxy resin casting/oil-immersed insulation for both indoor and outdoor use.
  • High-voltage Transformer (≥35kV): Applied to 110kV, 220kV and above high-voltage transmission systems, utilizing SF6 gas/oil-immersed insulation with high insulation strength and low partial discharge characteristics.

3.3 Classification by Structural Form

image

KITOZER Production Workshop

  • Electromagnetic Transformer: Traditional mainstream structure with silicon steel sheet iron core, mature technology, strong anti-interference capability and low cost for conventional working conditions, divided into dry-type, oil-immersed and cast-resin types.
  • Electronic Transformer: Includes Rogowski coil and optical sensing structures, free of magnetic saturation with wide dynamic range and digital output, suitable for smart substations and new energy scenarios.
  • **Split-core Transformer: Openable structure enabling installation without power outage, perfect for renovation of aging power distribution facilities and live construction projects.

3.4 Classification by Installation Method

  • Indoor Type: Installed inside switchgears and distribution cabinets, compact in size with moderate insulation grade.
  • Outdoor Type: For open-air power distribution and substation outdoor installation, featuring rain, aging and pollution flashover resistance.
  • Busbar-mounted Type: Directly sleeved onto busbars without primary winding wiring, easy to install for high-current scenarios.

4. System Schematic Diagrams

4.1 Current Transformer (CT) Schematic

Based on electromagnetic induction principles, the primary winding has few turns (1 turn or several turns) connected in series to the measured circuit; the multi-turn secondary winding is connected in series with measuring instruments and protection devices. The secondary side is strictly prohibited from open circuit, and terminal S2 must be reliably grounded to prevent high voltage from intruding into the secondary circuit.

4.2 Voltage Transformer (PT) Schematic

Adopting transformer operating principles, the primary winding is connected in parallel to the measured high-voltage line, and the secondary winding is connected in parallel with measuring instruments and protection devices. One-point grounding of the secondary side is mandatory for safety, with common V-V and Y-Y wiring modes.

4.3 Three-phase Current Transformer (Star Wiring) Schematic

Exclusive for three-phase four-wire systems. The S1 terminals of three CTs connect to phase A/B/C meters respectively, while S2 terminals are short-circuited and grounded to measure phase currents and zero-sequence currents, applicable to low-voltage power distribution and industrial motor protection.

4.4 Zero-sequence Transformer Schematic

The zero-sequence transformer sleeves three-phase cables. During normal operation, the vector sum of three-phase currents equals zero with no output signal; ground faults generate zero-sequence current, and the secondary output triggers tripping of protection devices, applied to leakage protection and ground fault monitoring.

5. Full System Configuration List (Classified by Low/Medium/High Voltage)

image

On-site Installation of Medium & High Voltage Transformers

5.1 Entry-level Configuration (Economical, for General Low-voltage Distribution & Civil Construction)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Low-voltage Measuring Current TransformerKTO-BH-0.66 50/5Rated Voltage: 0.66kV; Ratio: 50/5A; Accuracy Class: 0.5; Rated Burden: 2.5VA; Frequency: 50Hz; Insulation: Epoxy Resin Casting; Mounting: Busbar-mounted3SetKITOZERFor 0.4kV three-phase power distribution measurement
2Low-voltage Zero-sequence Current TransformerKTO-LX-0.66 100/5Rated Voltage: 0.66kV; Ratio: 100/5A; Accuracy Class: 10P10; Rated Burden: 5VA; Frequency: 50Hz; Structure: Split-core; Mounting: Cable-type1SetKITOZERLeakage & ground fault monitoring
3Low-voltage Voltage TransformerKTO-JD-0.66 100/√3/100/√3Rated Voltage: 0.66kV; Ratio: 100/√3/100/√3V; Accuracy Class: 0.5; Rated Burden: 5VA; Frequency: 50Hz; Wiring: Y-Y; Insulation: Dry-type3SetKITOZERVoltage measurement & overvoltage monitoring
4Mounting BracketKTO-ZJ-01Material: Cold-rolled Steel; Size: 100×80×5mm; Anti-rust Treatment: Electrostatic Plastic Spraying; Compatible with Low-voltage Transformer Wall Mounting7SetKITOZERFixed installation accessory
5Secondary Short-circuit WireKTO-DX-01Wire Gauge: 2.5mm²; Conductor: Copper Core; Insulation: PVC; Length: 50cm; Compatible with CT Secondary Short-circuit10PieceKITOZERPrevent secondary open circuit for safety protection

5.2 Standard Configuration (Medium-tier, for Industrial Distribution, Small & Medium Substations, New Energy Stations)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Medium-voltage Measuring Current TransformerKTO-LZZJ-10 200/5Rated Voltage: 10kV; Ratio: 200/5A; Accuracy Class: 0.2S; Rated Burden: 5VA; Frequency: 50Hz; Insulation Level: 12/42/75kV; Structure: Epoxy Resin Casting; Mounting: Indoor Cabinet-mounted3SetKITOZERIndustrial metering & trade settlement
2Medium-voltage Protection Current TransformerKTO-LZZJ-10 300/5Rated Voltage: 10kV; Ratio: 300/5A; Accuracy Class: 5P10; Rated Burden: 10VA; Frequency: 50Hz; Insulation Level: 12/42/75kV; Structure: Epoxy Resin Casting; Mounting: Indoor Cabinet-mounted3SetKITOZERShort-circuit & overcurrent protection
3Medium-voltage Voltage TransformerKTO-JDZJ-10 10/√3/0.1/√3Rated Voltage: 10kV; Ratio: 10/√3/0.1/√3V; Accuracy Class: 0.2; Rated Burden: 10VA; Frequency: 50Hz; Insulation Level: 12/42/75kV; Wiring: V-V; Structure: Epoxy Resin Casting2SetKITOZERVoltage measurement & relay protection signal transmission
4Zero-sequence Current TransformerKTO-LX-10 200/5Rated Voltage: 10kV; Ratio: 200/5A; Accuracy Class: 5P5; Rated Burden: 5VA; Frequency: 50Hz; Insulation: Cast-resin; Mounting: Cable-type1SetKITOZERHigh-voltage ground fault protection
5Outdoor Protection Combined TransformerKTO-JLSZV-10 10kVRated Voltage: 10kV; Current Ratio: 200/5A; Voltage Ratio: 10/0.1kV; Accuracy Class: 0.5S/0.5; Insulation: Outdoor Epoxy Resin Casting; Protection Class: IP651SetKITOZERIntegrated metering for outdoor small power distribution
6Special Mounting BaseKTO-ZD-02Material: Stainless Steel; Size: 150×120×8mm; Rust & Corrosion Resistant; Compatible with 10kV Transformer Indoor/Outdoor Installation10SetKITOZERStable fixing for harsh environments
7Secondary Shielded CableKTO-PB-02Wire Gauge: 4mm²; Cores: 2-core; Conductor: Copper Core; Insulation: Cross-linked Polyethylene; Shield: Copper Mesh; Length: 100m; For Secondary Signal Transmission2RollKITOZERAnti-interference for stable signal transmission

5.3 Premium Configuration (High-end, for Smart Substations, High-voltage Transmission, Large New Energy Stations, Rail Transit)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1High-voltage Measuring Current TransformerKTO-LGW-35 500/5Rated Voltage: 35kV; Ratio: 500/5A; Accuracy Class: 0.2S; Rated Burden: 15VA; Frequency: 50Hz; Insulation Level: 40.5/85/200kV; Structure: Oil-immersed; Mounting: Outdoor Vertical3SetKITOZERHigh-voltage metering & precise measurement
2High-voltage Protection Current TransformerKTO-LGW-35 600/5Rated Voltage: 35kV; Ratio: 600/5A; Accuracy Class: 5P20; Rated Burden: 20VA; Frequency: 50Hz; Insulation Level: 40.5/85/200kV; Structure: Oil-immersed; Mounting: Outdoor Vertical3SetKITOZERHigh-voltage short-circuit & overcurrent protection
3Electronic Current TransformerKTO-DCT-110 1000/5Rated Voltage: 110kV; Ratio: 1000/5A; Accuracy Class: 0.2; Output: Digital (IEC61850); Frequency: 50Hz; Insulation: SF6 Gas; No Magnetic Saturation, Wide Frequency Response2SetKITOZERSmart substation & digital power distribution
4High-voltage Voltage TransformerKTO-JGW-35 35/√3/0.1/√3Rated Voltage: 35kV; Ratio: 35/√3/0.1/√3V; Accuracy Class: 0.2; Rated Burden: 20VA; Frequency: 50Hz; Insulation Level: 40.5/85/200kV; Structure: Oil-immersed; Mounting: Outdoor Vertical3SetKITOZERHigh-voltage voltage monitoring & relay protection
5Optical Voltage TransformerKTO-OPT-220 220kVRated Voltage: 220kV; Accuracy Class: 0.1; Output: Optical Fiber Digital; Frequency: 50Hz; Insulation: All-fiber; Anti-electromagnetic Interference, Passive Explosion-proof1SetKITOZERExtra-high voltage transmission & smart grid
6Intelligent Zero-sequence TransformerKTO-LX-35 500/5Rated Voltage: 35kV; Ratio: 500/5A; Accuracy Class: 5P10; Rated Burden: 10VA; Frequency: 50Hz; Functions: Online Monitoring & Fault Alarm; Insulation: Composite Insulation1SetKITOZERPrecise high-voltage ground fault protection
7Stainless Steel Protection CabinetKTO-GJ-03Material: 304 Stainless Steel; Size: 800×600×400mm; Protection Class: IP66; Functions: Dustproof, Waterproof, Anti-corrosion, Temperature Control; For Outdoor Transformer Matching Protection2SetKITOZERExtend equipment service life
8Digital Signal CollectorKTO-CJ-01Input: Analog/Digital Signal; Output: RS485/Ethernet; Protocols: Modbus/IEC61850; Accuracy: 0.1; Functions: Signal Conversion, Data Upload, Remote Monitoring4SetKITOZERData transmission & remote operation for smart systems

6. Full Product Technical Parameters

image

Transformer Structural Dimension Drawing

6.1 Low-voltage Current Transformer (KTO-BH-0.66 Series)

  • Rated Voltage: 0.66kV
  • Rated Frequency: 50Hz/60Hz
  • Current Ratio Range: 5/5A ~ 5000/5A (1A output optional)
  • Accuracy Class: Measuring Class: 0.5, 0.5S, 0.2, 0.2S; Protection Class: 5P10, 10P10
  • Rated Burden: 2.5VA ~ 10VA
  • Insulation Type: Epoxy Resin Casting, Dry-type
  • Protection Class: IP40
  • Operating Temperature: -20℃ ~ +60℃
  • Mounting Methods: Busbar-mounted, Through-core, Split-core
  • Execution Standards: GB/T20840.2-2014, IEC61869-2

6.2 Medium-voltage Current Transformer (KTO-LZZJ-10 Series)

  • Rated Voltage: 10kV
  • Rated Frequency: 50Hz
  • Current Ratio Range: 50/5A ~ 3000/5A
  • Accuracy Class: Measuring Class: 0.2S, 0.5S; Protection Class: 5P10, 5P20
  • Rated Burden: 5VA ~ 15VA
  • Insulation Level: 12/42/75kV
  • Insulation Type: Epoxy Resin Casting (Indoor & Outdoor)
  • Protection Class: IP54
  • Operating Temperature: -30℃ ~ +70℃
  • Mounting Methods: Indoor Cabinet-mounted, Outdoor Vertical
  • Execution Standards: GB/T20840.2-2014, IEC61869-2

6.3 High-voltage Current Transformer (KTO-LGW-35 Series)

  • Rated Voltage: 35kV
  • Rated Frequency: 50Hz
  • Current Ratio Range: 200/5A ~ 5000/5A
  • Accuracy Class: Measuring Class: 0.2S; Protection Class: 5P20, PX
  • Rated Burden: 15VA ~ 30VA
  • Insulation Level: 40.5/85/200kV
  • Insulation Type: Oil-immersed, SF6 Gas Insulation
  • Protection Class: IP65
  • Operating Temperature: -40℃ ~ +85℃
  • Mounting Methods: Outdoor Vertical, GIS Integrated
  • Execution Standards: GB/T20840.2-2014, IEC61869-2

6.4 Low-voltage Voltage Transformer (KTO-JD-0.66 Series)

image

Low-voltage Transformer On-site Display

  • Rated Voltage: 0.66kV
  • Rated Frequency: 50Hz
  • Voltage Ratio: 100/√3/100/√3V
  • Accuracy Class: 0.5, 0.2
  • Rated Burden: 5VA ~ 10VA
  • Insulation Type: Dry-type, Epoxy Resin Casting
  • Protection Class: IP40
  • Operating Temperature: -20℃ ~ +60℃
  • Wiring Modes: Y-Y, V-V
  • Execution Standards: GB/T20840.3-2014, IEC61869-3

6.5 Medium-voltage Voltage Transformer (KTO-JDZJ-10 Series)

  • Rated Voltage: 10kV
  • Rated Frequency: 50Hz
  • Voltage Ratio: 10/√3/0.1/√3V
  • Accuracy Class: 0.2, 0.5
  • Rated Burden: 10VA ~ 20VA
  • Insulation Level: 12/42/75kV
  • Insulation Type: Epoxy Resin Casting
  • Protection Class: IP54
  • Operating Temperature: -30℃ ~ +70℃
  • Wiring Modes: V-V, Y-Y, Open Delta
  • Execution Standards: GB/T20840.3-2014, IEC61869-3

6.6 High-voltage Voltage Transformer (KTO-JGW-35 Series)

image

KITOZER Central Monitoring Platform

  • Rated Voltage: 35kV
  • Rated Frequency: 50Hz
  • Voltage Ratio: 35/√3/0.1/√3V
  • Accuracy Class: 0.2
  • Rated Burden: 20VA ~ 50VA
  • Insulation Level: 40.5/85/200kV
  • Insulation Type: Oil-immersed, SF6 Gas Insulation
  • Protection Class: IP65
  • Operating Temperature: -40℃ ~ +85℃
  • Wiring Modes: Y-Y, Open Delta
  • Execution Standards: GB/T20840.3-2014, IEC61869-3

6.7 Zero-sequence Current Transformer (KTO-LX Series)

  • Rated Voltage: 0.66kV ~ 35kV
  • Rated Frequency: 50Hz
  • Current Ratio: 50/5A ~ 1000/5A
  • Accuracy Class: 5P5, 5P10, 10P10
  • Rated Burden: 5VA ~ 10VA
  • Insulation Type: Epoxy Resin Casting, Composite Insulation
  • Protection Class: IP54
  • Operating Temperature: -30℃ ~ +70℃
  • Mounting Methods: Cable-type, Busbar-mounted
  • Execution Standards: GB/T20840.2-2014, DL/T727-2013

6.8 Electronic / Optical Transformer (KTO-DCT/OPT Series)

image

Transformer Cabinet Installation

  • Rated Voltage: 110kV ~ 220kV
  • Rated Frequency: 50Hz
  • Accuracy Class: 0.1, 0.2
  • Output Modes: Digital (IEC61850), Optical Fiber Signal
  • Insulation Type: SF6 Gas, All-fiber
  • Protection Class: IP65
  • Operating Temperature: -40℃ ~ +85℃
  • Core Features: No Magnetic Saturation, Wide Frequency Response, Anti-electromagnetic Interference, Passive Explosion-proof
  • Execution Standards: GB/T20840.5-2014, IEC61869-5

7. Full Product Application Scope

The complete KITOZER transformer series covers low-voltage power distribution, medium-voltage industry, high-voltage transmission, smart grids, new energy, rail transit, construction engineering, metallurgy & petrochemical, coal & chemical and other sectors, meeting four core demands: measurement, metering, protection and monitoring.

7.1 Low-voltage Transformer Application Scope

image

Low-voltage Distribution Cabinet Application

  • Civil Construction: Residential buildings, shopping malls, office building low-voltage power distribution systems for electric energy metering and current/voltage monitoring
  • Industrial Plants: Small factories & workshop 0.4kV power distribution for motor protection and energy consumption monitoring
  • Power Distribution Renovation: Split-core transformers for live renovation of aging residential & factory power systems without power outage
  • Photovoltaic & Energy Storage: Low-voltage side of distributed PV and energy storage stations for current collection and grid-connected monitoring

7.2 Medium-voltage Transformer Application Scope

  • Industrial Power Distribution: 6kV/10kV power distribution systems for steel, chemical, textile and machinery manufacturing plants for production equipment protection and trade settlement
  • Small & Medium Substations: Urban & county 10kV/35kV substations for line protection, voltage monitoring and electric energy metering
  • New Energy Stations: 35kV power distribution of centralized PV, wind power and biomass power stations for grid-connected protection and data collection
  • Rail Transit: Metro & light rail 10kV power supply systems for traction power protection and electrical parameter monitoring

7.3 High-voltage Transformer Application Scope

  • High-voltage Transmission: 35kV/110kV/220kV transmission lines of State Grid and China Southern Power Grid for electric energy metering, relay protection and fault monitoring
  • Large Substations: High-voltage side of hub substations and converter stations for system protection and precise measurement
  • Metallurgy & Petrochemical: 35kV high-voltage power distribution for large smelting and petrochemical enterprises to protect core equipment and measure energy consumption
  • Coal & Chemical Industry: Explosion-proof transformers for high-voltage power supply in underground coal mines and chemical parks to adapt to high-risk environments

7.4 Zero-sequence Transformer Application Scope

  • Low-voltage Power Distribution: Leakage protection for residential and commercial buildings to prevent electric shock and electrical fires
  • Medium & High Voltage Systems: 10kV/35kV ground fault protection to quickly locate fault points and isolate circuits via tripping
  • PV & Wind Power: Ground fault monitoring for new energy stations to ensure stable equipment operation and safety
  • Industrial Motors: High-voltage motor ground fault protection to avoid motor burnout and production interruption

7.5 Electronic / Optical Transformer Application Scope

  • Smart Substations: New-generation digital smart substations for digital signal transmission and remote operation & maintenance
  • Extra-high Voltage Transmission: 220kV and above EHV/UHV transmission systems for high-precision measurement and anti-interference performance
  • New Energy Power Grid: Intelligent grid connection for large wind & PV bases with wide frequency response to adapt to harmonic environments
  • Special Working Conditions: Passive explosion-proof design for strong electromagnetic interference and high-risk environments such as coal mines, chemical plants and metallurgical factories

8. Full Product Advantages

Backed by independent R&D technology, advanced production processes, strict quality control and customized services, the full KITOZER transformer series boasts four core strengths in function, customization, production & supply chain and technical parameters, supporting OEM/ODM processing, confidential production and spot supply to meet differentiated customer demands.

8.1 Functional Advantages

  • High-precision Measurement: Premium silicon steel sheet / amorphous alloy iron core, up to 0.2S high precision with error ≤0.2%, satisfying trade settlement and accurate metering requirements
  • Superior Stability: Full-sealed insulation design with moisture, pollution and aging resistance, stably operating in extreme temperatures of -40℃ ~ +85℃ with zero long-term failure
  • Strong Anti-interference Performance: Optimized winding layout for electromagnetic transformers and optical fiber transmission for electronic transformers to resist electromagnetic interference and deliver distortion-free signals
  • Safe & Reliable: High-low voltage electrical isolation plus secondary grounding protection to eliminate high-voltage intrusion risks; zero-sequence products accurately detect ground faults to prevent electrical fires
  • Wide Compatibility: Full coverage of voltage grades, structural forms and mounting methods, compatible with indoor/outdoor, conventional/harsh, general/high-risk working conditions
  • Intelligent Upgrade: Electronic & optical transformers support digital output, remote monitoring and fault alarms, aligning with smart grid and digital power distribution trends

8.2 Customization Advantages

  • Parameter Customization: Customizable current ratio, accuracy class, rated burden and voltage grade to match special operating condition parameters
  • Structural Customization: Custom split-core, closed, busbar and cable-type structures for unique installation spaces and construction methods
  • Material Customization: Custom epoxy resin, insulating oil, SF6 gas and all-fiber insulation materials for humid, polluted and explosion-prone harsh environments
  • Function Customization: Add online monitoring, fault alarm, data transmission and remote control functions for intelligent system integration
  • Dimension Customization: Custom special outlines and sizes to fit non-standard switchgears and narrow installation spaces

8.3 Production & Supply Chain Advantages

  • OEM/ODM Processing Service: Support branded OEM production and customized solution design with full technical support to help customers build proprietary brands
  • Confidential Production: Sign non-disclosure agreements to strictly protect customized schemes, technical parameters and production processes from information leakage
  • Spot Supply: Mass inventory of standard low/medium voltage models with delivery within 72 hours to shorten lead times
  • Fast Delivery: Prototypes available within 7 days for customized models, mass delivery within 15 days for urgent project demands
  • Independent Production: Self-owned manufacturing base with full in-house production to control raw material procurement, production processes and factory inspection for consistent product quality

8.4 Core Technical Parameter Advantages

  • Precision Edge: Top measuring class up to 0.1, protection class 5P20 with error far below national standards for accurate metering and reliable protection
  • Insulation Performance: Medium & high voltage products feature insulation levels from 12/42/75kV to 40.5/85/200kV with high insulation strength to prevent insulation breakdown and electric leakage
  • Wide Temperature Adaptability: Operating temperature range of -40℃ ~ +85℃ to adapt to severe cold in northern regions, high temperature exposure in southern outdoor environments
  • High Protection Grade: Indoor IP40, outdoor IP54 and high-voltage outdoor IP65 for dust, water and corrosion resistance to extend equipment service life
  • Dual Frequency Support: Compatible with 50Hz/60Hz dual frequency to fit domestic and international power grid standards

9. Bid-winning Controllable Product Parameters (Marked with Asterisk)

9.1 General Controllable Parameters

*1. Brand: KITOZER (Kaifazhe), self-owned brand with independent production (not third-party OEM)

*2. Execution Standards: Comply with national & industry standards GB/T20840-2014, IEC61869, DL/T727-2013

*3. Insulation Level: Low-voltage ≥0.66kV, medium-voltage ≥12/42/75kV, high-voltage ≥40.5/85/200kV

*4. Operating Temperature: -40℃ ~ +85℃ for extreme environmental adaptability

*5. Protection Grade: Indoor ≥IP40, outdoor ≥IP54, high-voltage outdoor ≥IP65

*6. Accuracy Class: Measuring class ≥0.2S, protection class ≥5P10, zero-sequence ≥5P5

*7. Rated Frequency: Support 50Hz/60Hz dual frequency for multi-scenario power grid compatibility

*8. Product Certification: ISO9001 quality management system certification, State Grid certification and third-party testing institute certification

9.2 Low-voltage Transformer Controllable Parameters

*1. Rated Voltage: ≥0.66kV for low-voltage power distribution system compatibility

*2. Current Ratio Range: 5/5A ~ 5000/5A, 1A output customizable

*3. Insulation Type: Epoxy resin casting / dry-type with full-sealed design

*4. Mounting Methods: Support busbar-mounted, through-core and split-core types for live installation without power outage

9.3 Medium-voltage Transformer Controllable Parameters

*1. Rated Voltage: ≥10kV for medium-voltage industrial power distribution

*2. Accuracy Class: Measuring class 0.2S, protection class 5P20 to meet trade settlement and protection demands

*3. Insulation Type: Outdoor epoxy resin casting with anti-pollution flashover and anti-aging performance

*4. Rated Burden: ≥5VA to guarantee secondary side load capacity

9.4 High-voltage Transformer Controllable Parameters

*1. Rated Voltage: ≥35kV for high-voltage transmission systems

*2. Insulation Type: Oil-immersed / SF6 gas insulation with high insulation strength and low partial discharge

*3. Accuracy Class: Measuring class 0.2, protection class 5P20 for high-voltage precise measurement and protection

*4. Protection Grade: IP65 dustproof, waterproof and anti-corrosion for harsh outdoor environments

9.5 Electronic / Optical Transformer Controllable Parameters

*1. Output Mode: Digital (IEC61850) / optical fiber signal for smart substation compatibility

*2. Core Features: No magnetic saturation, wide frequency response, anti-electromagnetic interference, passive explosion-proof

*3. Accuracy Class: ≥0.2, ≥0.1 for extra-high voltage scenarios

*4. Communication Protocols: Support Modbus / IEC61850 for intelligent system integration

9.6 Zero-sequence Transformer Controllable Parameters

*1. Rated Voltage: Compatible with full voltage grades 0.66kV ~ 35kV

*2. Accuracy Class: ≥5P5 for accurate ground fault detection

*3. Insulation Type: Composite insulation with moisture, pollution and high temperature resistance

10. Full Product Solutions

10.1 Low-voltage Power Distribution Transformer Solution

10.1.1 Solution Overview

Compatible with 0.4kV/0.66kV low-voltage power distribution systems, combining KITOZER low-voltage current, voltage and zero-sequence transformers to realize four core functions: current & voltage measurement, electric energy metering, leakage protection and energy consumption monitoring. Ideal for civil construction, industrial plants, power distribution renovation and PV & energy storage projects with convenient installation, cost efficiency and reliable safety performance.

10.1.2 Solution Configuration

  • Core Equipment: Low-voltage measuring & zero-sequence current transformers, low-voltage voltage transformers, secondary short-circuit wires, mounting brackets
  • Wiring Rules: Current transformers connected in series to circuits with S2 terminal grounded; voltage transformers connected in parallel with one-point secondary grounding; zero-sequence transformers sleeved on three-phase cables to monitor zero-sequence current
  • Core Advantages: Split-core design enables live installation without power cut; 0.5S precision meets metering standards; zero-sequence protection prevents electric fires; full-sealed design adapts to humid environments

10.1.3 Application Scenarios

  • Civil Construction: Power distribution rooms of residential buildings, shopping malls and office buildings for electric energy metering and leakage protection
  • Industrial Plants: 0.4kV power distribution for small factories and workshops for motor protection and energy consumption monitoring
  • Power Distribution Renovation: Live upgrade of aging residential & factory power systems with fast installation without production interruption
  • PV & Energy Storage: Low-voltage side of distributed PV and energy storage stations for current collection and grid-connected monitoring

10.2 Medium-voltage Industrial Transformer Solution

10.2.1 Solution Overview

Designed for 10kV/35kV medium-voltage industrial power distribution systems, integrating KITOZER medium-voltage measuring & protection current transformers, voltage transformers, zero-sequence transformers and combined transformers to deliver four core functions: precise metering, relay protection, voltage monitoring and fault location. Suitable for industrial power distribution, small & medium substations, new energy stations and rail transit with strong stability, wide compatibility and easy maintenance.

10.2.2 Solution Configuration

  • Core Equipment: Medium-voltage 0.2S measuring & 5P20 protection current transformers, medium-voltage voltage transformers, zero-sequence transformers, combined transformers, secondary shielded cables, special mounting bases
  • Wiring Rules: Star wiring of current transformers for three-phase four-wire systems; V-V wiring of voltage transformers to reduce equipment quantity; zero-sequence transformers detect ground faults for fast circuit tripping and isolation
  • Core Advantages: Epoxy resin casting insulation with anti-pollution flashover and anti-aging performance; 0.2S precision for trade settlement; 5P20 protection class for short-circuit fault response; outdoor IP54 protection for harsh environments

10.2.3 Application Scenarios

  • Industrial Power Distribution: 10kV power distribution for steel, chemical and textile enterprises for production equipment protection and energy consumption metering
  • Small & Medium Substations: 10kV/35kV urban & county substations for line protection and voltage monitoring
  • New Energy Stations: 35kV power distribution of centralized PV and wind power plants for grid-connected protection and data collection
  • Rail Transit: 10kV power supply for metro & light rail for traction power protection and electrical parameter monitoring

10.3 High-voltage Transmission Transformer Solution

10.3.1 Solution Overview

Applied to 35kV/110kV/220kV high-voltage transmission systems, combining KITOZER high-voltage current & voltage transformers, electronic/optical transformers and intelligent zero-sequence transformers to realize four core functions: high-precision high-voltage measurement, relay protection, fault monitoring and digital signal transmission. Adaptable to high-voltage transmission, large substations, metallurgy & petrochemical and coal & chemical industries with high insulation strength, superior stability, intelligent upgrade capability and full safety.

10.3.2 Solution Configuration

  • Core Equipment: High-voltage 0.2S measuring & 5P20 protection current transformers, high-voltage voltage transformers, electronic/optical transformers, intelligent zero-sequence transformers, stainless steel protection cabinets, digital signal collectors
  • Wiring Rules: Vertical outdoor installation of high-voltage transformers with shielded secondary cable transmission; optical fiber connection for electronic transformers to upload digital signals; zero-sequence transformers monitor ground faults with remote alarm function
  • Core Advantages: Oil-immersed / SF6 gas insulation with high insulation strength and low partial discharge; 0.2 precision for high-voltage metering; electronic transformers eliminate magnetic saturation and resist electromagnetic interference; intelligent monitoring supports remote operation & maintenance

10.3.3 Application Scenarios

  • High-voltage Transmission: 35kV ~ 220kV transmission lines of State Grid and China Southern Power Grid for electric energy metering and relay protection
  • Large Substations: High-voltage side of hub substations and converter stations for system protection and precise measurement
  • Metallurgy & Petrochemical: 35kV high-voltage power distribution for large smelting and petrochemical enterprises to protect core production equipment
  • Coal & Chemical Industry: High-voltage power supply for underground coal mines and chemical parks with explosion-proof models for high-risk environments

10.4 Smart Substation Transformer Solution

10.4.1 Solution Overview

Tailored for new-generation digital smart substations, combining KITOZER electronic/optical transformers, intelligent zero-sequence transformers and digital signal collectors to deliver four core functions: digital measurement, intelligent protection, remote monitoring and fault early warning. Free of magnetic saturation, anti-electromagnetic interference, passive explosion-proof and fully aligned with smart grid development trends.

10.4.2 Solution Configuration

  • Core Equipment: Electronic current transformers, optical voltage transformers, intelligent zero-sequence transformers, digital signal collectors, intelligent operation & maintenance terminals
  • Wiring Rules: Optical fiber connection for electronic transformers to output digital IEC61850 signals; passive optical transformers transmit signals via optical fiber; intelligent collectors upload data for remote monitoring
  • Core Advantages: No magnetic saturation & wide frequency response to adapt to harmonic-rich environments; optical fiber transmission eliminates electromagnetic signal distortion; passive explosion-proof design for high safety; digital output compatible with intelligent system integration

10.4.3 Application Scenarios

  • Smart Substations: New-generation digital smart substations for process layer data collection and protection control
  • Extra-high Voltage Transmission: 220kV and above EHV/UHV transmission systems for high-precision measurement and anti-interference performance
  • New Energy Power Grid: Intelligent grid connection for large wind & PV bases with harmonic adaptation and stable operation
  • Special Working Conditions: Coal mines, chemical plants, metallurgical factories and other high-electromagnetic-interference high-risk environments with stable and safe operation

11. Full Product Application Cases

11.1 Civil Construction Low-voltage Distribution Case – Large Shopping Mall Power Distribution Renovation Project in Guangzhou

11.1.1 Project Profile

A 50,000 ㎡ large shopping mall in Guangzhou suffered aging 0.4kV power distribution systems with inaccurate metering and leakage hazards. Live renovation was required to replace transformers and supporting equipment to guarantee stable power supply, precise metering and safety protection.

11.1.2 Product Configuration

  • Low-voltage Measuring Current Transformer (KTO-BH-0.66 200/5): 12 sets, 0.5S class for measurement
  • Low-voltage Zero-sequence Transformer (KTO-LX-0.66 300/5): 4 sets, 10P10 class for leakage protection
  • Low-voltage Voltage Transformer (KTO-JD-0.66): 12 sets, 0.5 class for voltage monitoring
  • Supporting Accessories: Secondary short-circuit wires, mounting brackets, shielded cables

11.1.3 Project Outcomes

  • Split-core transformers enabled live installation without suspending mall operation
  • 0.5S precision limited electric energy metering error within 0.5%, reducing electricity cost losses
  • Zero-sequence leakage protection eliminated risks of electric fires and electric shock injuries
  • Full-sealed design adapted to humid mall environments with zero equipment failure during operation

11.2 Industrial Medium-voltage Distribution Case – 10kV Power Distribution Project of a Steel Plant in Foshan

11.2.1 Project Profile

A 1 million-ton annual output steel plant in Foshan relies on a 10kV power distribution system to supply core production equipment, demanding precise metering and reliable protection for harsh high-temperature, dusty and strong electromagnetic interference working conditions.

11.2.2 Product Configuration

  • Medium-voltage Current Transformer (KTO-LZZJ-10 500/5): 18 sets, 0.2S measuring class + 5P20 protection class
  • Medium-voltage Voltage Transformer (KTO-JDZJ-10): 6 sets, 0.2 class for voltage monitoring
  • Zero-sequence Transformer (KTO-LX-10 600/5): 3 sets, 5P10 class for ground fault protection
  • Supporting Accessories: Special mounting bases, secondary shielded cables, outdoor protection housings

11.2.3 Project Outcomes

  • Epoxy resin casting insulation delivered dustproof and high-temperature resistance to adapt to the steel plant’s harsh environment
  • 0.2S precision achieved trade settlement metering error ≤0.2%
  • 5P20 protection class triggered fast tripping for short-circuit faults to safeguard core production equipment
  • IP54 outdoor protection resulted in zero equipment failures over 3 years of operation, cutting maintenance costs by 80%

11.3 High-voltage Transmission Case – 35kV Transmission Line Project of China Southern Power Grid

11.3.1 Project Profile

A 20km 35kV transmission line of China Southern Power Grid crosses mountainous and hilly terrain, requiring precise high-voltage measurement and reliable relay protection for harsh outdoor high-temperature, low-temperature and polluted environments.

11.3.2 Product Configuration

  • High-voltage Current Transformer (KTO-LGW-35 800/5): 6 sets, 0.2S measuring class + 5P20 protection class
  • High-voltage Voltage Transformer (KTO-JGW-35): 6 sets, 0.2 class for voltage monitoring
  • Intelligent Zero-sequence Transformer (KTO-LX-35 1000/5): 2 sets, 5P10 class for ground fault monitoring
  • Supporting Accessories: Stainless steel protection cabinets, digital signal collectors, SF6 gas insulation components

11.3.3 Project Outcomes

  • SF6 gas insulation offered high insulation strength and low partial discharge to adapt to polluted mountainous environments
  • 0.2 precision met high-voltage transmission metering standards for grid settlement
  • Intelligent zero-sequence monitoring enabled fast ground fault location and remote alarm
  • IP65 protection withstood extreme high and low outdoor temperatures, delivering zero failures over 5 years of stable operation

11.4 Smart Substation Case – 110kV Smart Substation Project in Shenzhen

11.4.1 Project Profile

A new-generation digital 110kV smart substation in central Shenzhen required digital measurement, intelligent protection and remote monitoring to adapt to strong electromagnetic interference in urban core zones.

11.4.2 Product Configuration

  • Electronic Current Transformer (KTO-DCT-110 1200/5): 4 sets, 0.2 class with digital output
  • Optical Voltage Transformer (KTO-OPT-220): 2 sets, 0.1 class with optical fiber signal transmission
  • Intelligent Zero-sequence Transformer (KTO-LX-35): 2 sets with intelligent monitoring and fault alarm functions
  • Supporting Accessories: Digital signal collectors, intelligent operation & maintenance terminals, optical fiber communication components

11.4.3 Project Outcomes

  • No magnetic saturation and wide frequency response adapted to substation harmonic environments for consistent precise measurement
  • Optical fiber transmission eliminated electromagnetic interference to deliver distortion-free stable signals for urban core zone operation
  • Passive explosion-proof design eliminated explosion hazards with maximum safety
  • Digital output integrated with intelligent systems to enable remote monitoring and fault early warning, boosting operation & maintenance efficiency by 90%

12. Product Common Faults & Maintenance Specifications

12.1 Common Faults & Troubleshooting Methods

12.1.1 Common Current Transformer Faults

  1. Secondary Open Circuit (Most Dangerous Fault)
    • Phenomenon: Thousands of volts of high voltage generated on secondary side with buzzing noise and discharge sparks; ammeter reading drops to zero, protection malfunctions or fails to act
    • Root Causes: Loose wiring terminals, broken secondary wires, unremoved short-circuit wires after testing
    • Handling: Cut power supply for maintenance immediately; if power cut is unavailable, reliably short-circuit test terminals with dedicated short-circuit wires first before locating open-circuit points; strictly prohibit touching live secondary circuits
  2. Abnormal Overheating
    • Phenomenon: Excessively high equipment temperature, discolored housing, burnt odor or smoke emission
    • Root Causes: Long-term overload, excessive primary current, poor contact of wiring terminals, inadequate heat dissipation
    • Handling: Reduce load to avoid sustained overload; cut power to fasten wiring terminals with standard torque; clean surface dust and optimize heat dissipation conditions
  3. Precision Deviation
    • Phenomenon: Large deviation between measured and actual values, inaccurate metering and shifted protection action values
    • Root Causes: Iron core saturation, residual magnetism accumulation, aging insulation, mismatched secondary load
    • Handling: Reduce primary overload to eliminate residual magnetism; replace aging insulation components; adjust secondary load to match rated burden
  4. Abnormal Noise
    • Phenomenon: Uneven buzzing, discharge or vibration sounds inside the unit
    • Root Causes: Loose iron core clamping bolts, uncompressed silicon steel sheets, partial discharge, minor secondary open circuit
    • Handling: Cut power to fasten iron core clamping bolts to standard torque; inspect insulation to eliminate partial discharge; troubleshoot secondary circuits to repair open-circuit faults

12.1.2 Common Voltage Transformer Faults

  1. Ferroresonance (Frequent in High-voltage PTs)
    • Phenomenon: Loud buzzing or crackling noise, violent fluctuation of voltmeter readings, potential PT burnout and insulation breakdown
    • Root Causes: Resonance loop formed by system ground capacitance and PT inductance; easily triggered during empty bus charging or single-phase ground fault clearance
    • Handling: Install resonance elimination devices; adjust system operation mode to break resonance conditions; replace anti-resonance PT models
  2. Blown High-voltage Fuse
    • Phenomenon: Abnormal voltmeter readings (one phase voltage drops or reaches zero), low active/reactive power meter readings, abnormal PT noise
    • Root Causes: System short-circuit, internal PT failure, aging fuses
    • Handling: Cut power to replace fuses and inspect internal PT faults; eliminate hidden system short-circuit hazards
  3. Insulation Damage & Discharge
    • Phenomenon: Partial discharge, increased dielectric loss, severe insulation breakdown and short-circuit
    • Root Causes: Aging insulation, moisture ingress, overvoltage impact, manufacturing defects
    • Handling: Cut power to test insulation resistance and dielectric loss values; dry or replace insulation components; install overvoltage protection devices

12.1.3 Common Zero-sequence Transformer Faults

  1. No Output Signal
    • Phenomenon: Protection fails to activate during ground faults with zero signal output
    • Root Causes: Broken secondary wires, incorrect wiring, damaged iron core, short-circuited load
    • Handling: Inspect secondary wiring and repair broken cables; check iron core and replace damaged parts; eliminate load short-circuit faults
  2. False Alarm
    • Phenomenon: Frequent ground fault alarms under normal operating conditions
    • Root Causes: Unbalanced three-phase current, external electromagnetic interference, improper installation position
    • Handling: Adjust three-phase load to balance current; relocate equipment away from high-electromagnetic devices; install shielding devices

12.2 Daily Maintenance Specifications

12.2.1 Low-voltage Transformer Maintenance (Every 6 Months)

  • Visual Inspection: Remove surface dust and oil stains; check housing for cracks, deformation and rust
  • Wiring Inspection: Fasten wiring terminals to eliminate looseness, oxidation and corrosion; verify reliable secondary grounding
  • Insulation Test: Measure insulation resistance with megohmmeter (≥0.5MΩ for low-voltage units; dry or replace equipment if unqualified)
  • Functional Test: Power on to calibrate current and voltage readings for qualified precision; test zero-sequence alarm function for normal response

12.2.2 Medium-voltage Transformer Maintenance (Every 12 Months)

  • Surface Cleaning: Remove dust and pollution deposits; inspect epoxy housing for cracks, aging and tracking marks
  • Terminal Fastening: Tighten primary & secondary wiring bolts to standard torque (25–30N·m for M10 bolts)
  • Insulation Test: Measure insulation resistance (≥1000MΩ) and dielectric loss (≤0.5% at 90℃)
  • Oil Level Inspection (Oil-immersed Models): Check normal oil level with no leakage; test oil samples (breakdown voltage ≥45kV/2.5mm, water content ≤15ppm)
  • Precision Calibration: Calibrate transformation ratio and precision with professional instruments to meet error standards; test reliable protection function response

12.2.3 High-voltage Transformer Maintenance (Every 18 Months)

  • Outdoor Cleaning: Remove dust, pollution and bird droppings; verify normal SF6 gas pressure with no leakage
  • Sealing Inspection: Check aging or damaged sealing glue and gaskets to block moisture and dust intrusion
  • Insulation Test: Conduct power frequency withstand voltage and partial discharge tests to meet insulation standards (partial discharge ≤100pC)
  • Component Maintenance: Replace silica gel desiccant when 2/3 discolored (dry new silica gel at 120℃ for 8 hours); lubricate transmission parts with molybdenum disulfide grease
  • Intelligent Inspection: Check optical fiber connection integrity for electronic/optical transformers; verify stable digital signal transmission and normal remote monitoring functions

12.2.4 Special Environment Maintenance

  • Heavy Pollution Zones: Clean twice annually for Class III pollution areas, quarterly for Class IV pollution areas; re-coat RTV anti-pollution flashover coating every 5 years, PRTV coating every 8 years
  • Severe Cold Zones: Adopt -40℃ low-temperature resistant oil; inspect oil levels weekly in winter; install heating devices to maintain tank temperature ≥-30℃
  • Humid Zones: Increase insulation test frequency to every 6 months; inspect sealing to prevent moisture ingress; install dehumidifiers if required

13. Factory Strength & After-sales Service

13.1 Factory Strength

KITOZER transformers are independently researched, developed and manufactured by Guangzhou Laian Intelligent System Development Co., Ltd., a high-tech enterprise integrating R&D, production, sales and after-sales service. With 18 years of deep experience in power transformer manufacturing, the company specializes in R&D and production of high/low voltage transformers and power distribution supporting equipment, equipped with self-owned production bases, advanced production machinery, professional technical teams and complete quality control systems.

13.1.1 Production Scale

  • Production Base: 6,000 ㎡ manufacturing plant in Guangzhou with 3 standardized workshops, annual output capacity of 100,000 sets of transformers
  • Production Equipment: Over 100 sets of advanced German & Japanese manufacturing machinery including automatic winding machines, epoxy resin vacuum casting equipment, SF6 gas insulation treatment equipment and laser marking machines for full-process automated production to guarantee consistent product stability
  • Staff Team: Over 200 employees, including 15 senior engineers, 30 mid-level technicians and 25 R&D specialists. Core technical team holds over 20 years of power equipment R&D experience with independent customized design capability

13.1.2 R&D & Quality Control

  • R&D Capacity: Independent R&D of three product lines (electromagnetic, electronic, optical transformers) with 12 patented technologies. Products pass ISO9001 quality management system certification, State Grid certification and third-party testing institute certification, fully compliant with GB/T20840, IEC61869 and other domestic & international standards
  • Quality Control System: Full-process QC covering raw material procurement, production processing, factory inspection and after-sales tracking. Premium ISO-certified silicon steel sheets, amorphous alloy and epoxy resin raw materials; full monitoring of production processes with 100% inspection of key procedures; full testing of insulation, precision, withstand voltage and partial discharge before delivery to achieve 100% factory pass rate with zero defective products shipped
  • Customization Capacity: Full customization of parameters, structure, material, function and dimensions; prototype delivery within 7 days, mass production within 15 days for urgent non-standard project demands. OEM/ODM processing and confidential production services with strict protection of customer technical schemes

13.1.3 Industry Track Record

  • Cooperative Clients: Over 5,000 customers including State Grid, China Southern Power Grid, large industrial enterprises, new energy stations and rail transit companies, covering 30 provinces and municipalities nationwide with product exports to Southeast Asia, Africa, Europe and other regions
  • Typical Cases: Guangzhou shopping mall power distribution renovation, Foshan steel plant 10kV power distribution, China Southern Power Grid 35kV transmission line, Shenzhen 110kV smart substation and other projects with stable equipment operation and high customer recognition

13.2 After-sales Service

Adhering to the service philosophy of “Customer First, Service-oriented, Fast Response, Full-cycle Support”, KITOZER establishes a 24-hour response, nationwide coverage, professional engineering team and lifetime maintenance after-sales system to deliver comprehensive full-lifecycle support for customers.

13.2.1 Service Commitments

  • Warranty Period: 3-year full product warranty; free repair, spare part replacement and technical support for non-human damage within warranty
  • Response Time: 24-hour service hotline with 1-hour response for consultation and fault repair requests; technical solutions provided within 4 hours; on-site service available nationwide within 24 hours with priority handling for critical faults
  • Lifetime Maintenance: Lifetime maintenance service after warranty expiry, only charging spare part material costs with free permanent technical consultation and upgrade support
  • Free Training: Free on-site & online training for product installation, commissioning, operation and maintenance to ensure customer mastery of equipment operation and maintenance skills

13.2.2 Service Content

  • Pre-sales Service: Free technical consultation, scheme design, model selection guidance and quotation; free sample testing to match customer working condition demands
  • In-sales Service: Full follow-up by professional technical teams with on-site installation guidance, commissioning and acceptance to guarantee proper equipment installation and stable operation
  • After-sales Service
    1. Fault Handling: 24-hour fault reporting with fast fault localization and on-site repair to minimize equipment downtime
    2. Regular Inspection: 1–2 free annual on-site inspections to check equipment operating status, conduct maintenance and eliminate hidden faults in advance
    3. Technical Upgrade: Free product technical upgrade and software update to align with industry technological progress and customer demand evolution
    4. Spare Parts Supply: Mass inventory of standard spare parts with delivery within 72 hours; priority rapid production of customized spare parts to support customer maintenance

13.2.3 Service Network

  • Nationwide Service Outlets: 10 major service centers and 50 service stations covering all provinces and municipalities across China for localized fast support
  • Professional Service Team: Over 100 certified professional after-sales engineers with rich on-site experience to rapidly resolve all types of equipment faults and technical issues

14. Conclusion

As core supporting equipment for power distribution systems, the KITOZER transformer series delivers full product coverage, high-precision stable performance, strict quality control, powerful customization capability and comprehensive after-sales service, compatible with low/medium/high voltage and smart grid full-scenario demands. Widely applied in industry, new energy, rail transit and construction engineering, it provides core guarantee for safe, stable power system operation, accurate metering and reliable protection.

Guangzhou Laian Intelligent System Development Co., Ltd. has focused on power equipment manufacturing for 18 years, adhering to the core values of “Technological Innovation, Quality Priority, Service Excellence, Win-win Cooperation”. Leveraging independent R&D strength, advanced production processes, strict quality control systems and professional service teams, the company continuously supplies high-quality transformer products, customized solutions and full-cycle after-sales service for global customers.

In the future, KITOZER will continue to invest in power equipment technological innovation, upgrade product performance and expand application scenarios. With higher-quality products, professional technical support and comprehensive service systems, we will boost smart grid construction, new energy development and industrial power distribution upgrading, cooperate with all partners for mutual benefit and create a promising future for the power industry.

15. SEO Keywords & Tags

15.1 Core Keyword System

Primary Core Keywords

Transformer, KITOZER Transformer, Kaifazhe Transformer, Power Distribution Supporting Transformer

High-conversion Long-tail Keywords

Current Transformer, Voltage Transformer, Zero-sequence Transformer, Medium-voltage Transformer, High-voltage Transformer, Low-voltage Transformer, Electronic Transformer, Optical Transformer, Intelligent Transformer, Transformer Solution, Transformer Manufacturer, Custom Transformer, Transformer OEM Processing

Industry Traffic Keywords

Power Transformer, Industrial Transformer, New Energy Transformer, Smart Grid Transformer, Rail Transit Transformer, Construction Engineering Transformer, Metallurgy & Petrochemical Transformer, Coal & Chemical Transformer, Transformer Application, Transformer Technical Parameters, Transformer Fault Maintenance

Brand Exclusive Keywords

KITOZER, Kaifazhe, Guangzhou Laian, KITOZER Current Transformer, KITOZER Voltage Transformer, KITOZER Zero-sequence Transformer

Search Suggestion & Related Search Keywords

Transformer Model Selection, Transformer Operating Principle, Transformer Wiring Diagram, Transformer Accuracy Class, Transformer Installation, Transformer Maintenance, Transformer Price, Transformer Brand, Transformer Application Case, Transformer Bid-winning Controllable Parameters

15.2 SEO Optimization Tag System

Core Page Optimization Tag

KITOZER Transformer | Power Distribution Supporting Transformer | Current, Voltage & Zero-sequence Transformer Solutions

Title Tag

KITOZER Transformer Solutions – Current, Voltage & Zero-sequence Transformer Manufacturer | Custom OEM & Spot Supply

Meta Keywords Tag

Transformer, KITOZER Transformer, Current Transformer, Voltage Transformer, Zero-sequence Transformer, Medium/High/Low Voltage Transformer, Transformer Solution, Transformer Manufacturer, Custom OEM Processing

Meta Description Tag

KITOZER (Kaifazhe) is a professional transformer manufacturer supplying full-series low/medium/high voltage current, voltage, zero-sequence and electronic transformers for industry, new energy and smart grid scenarios. We support customization, OEM confidential production and spot stock supply, with complete solutions, technical parameters, application cases, fault maintenance and after-sales service attached.

H1 Tag

KITOZER (Kaifazhe) Transformer Solution

H2 Tags

System Overview, System Composition, System Classification, System Schematic Diagrams, System Configuration List, Product Technical Parameters, Product Application Scope, Product Advantages, Bid-winning Controllable Parameters, Product Solutions, Application Cases, Product Faults & Maintenance, Factory Strength & After-sales Service, Conclusion

Internal Link Anchor Text Tags

  • Core Anchor Text: Transformer, KITOZER Transformer, Current Transformer, Voltage Transformer, Zero-sequence Transformer
  • Long-tail Anchor Text: Medium-voltage Transformer, High-voltage Transformer, Low-voltage Transformer, Electronic Transformer, Transformer Solution, Custom Transformer, Transformer OEM Processing
  • Related Anchor Text: Power Distribution Supporting Equipment, Smart Grid Equipment, New Energy Power Equipment, Industrial Power Distribution Equipment

快速

图像生成

帮我写作

翻译

PPT 生成

视频生成

深入研究

AI 播客

更多

Shopping Cart