Table of Contents
ToggleProduct Overview
The KITOZER tube-based fire extinguishing device is a self-actuating, pre-piped fire suppression system that uses a polymer detection tube routed directly around protected equipment to sense and extinguish incipient fires without any external power supply or fire alarm panel. When the tube contacts flame, it bursts at the hottest point, automatically opening the cylinder valve through stored pressure and releasing the clean agent through the burst point directly onto the fire. This passive, independent design makes the tube-based device ideal for protecting electrical enclosures, battery cabinets, server racks, and engine compartments where installing a full gas system is impractical.
The detection tube serves two roles at once: it senses the fire by bursting when exposed to heat, and it acts as the discharge pipe, carrying agent from the cylinder directly to the burst point. This dual function eliminates the need for separate smoke detectors, control panels, and piping. The system works even during a power outage, because it has no electrical components. KITOZER supplies the device with FM200, perfluorohexane, or FK-5-1-12 agent options, and the tube can be cut to length on site to fit the protected enclosure.
Technical Specifications
Cylinder 2 kg FM200 or perfluorohexane agent, storage pressure 2.5 MPa nitrogen, cylinder material 34CrMo4 steel, detection tube nylon reinforced polymer 8 mm OD, tube length up to 6 meters, activation temperature 170 degrees Celsius burst, manual release lever, pressure gauge, solenoid release option 24V DC for remote alarm integration, mounting bracket steel, net weight 4.5 kg, CCCF certified, GB 29550. Operating temperature minus 20 to 50 degrees Celsius, response time under 5 seconds.
The cylinder is a small seamless steel bottle, 150 mm diameter and 400 mm tall, mounted on a steel bracket that can be bolted to the enclosure wall. The valve is a spring-loaded brass body held closed by pressure, and it opens automatically when the tube bursts because the pressure drop actuates a small piston. A manual lever allows the cylinder to be discharged deliberately for testing. The detection tube is 8 mm outside diameter, nylon reinforced, rated for 170 degrees Celsius burst, with a minimum bend radius of 50 mm. The optional 24V DC solenoid allows remote release from a fire alarm panel, and a pressure switch sends an alarm when the cylinder discharges.
Application Scenarios
This device protects equipment enclosures and small spaces such as server racks, UPS cabinets, battery energy storage cabinets, electrical switchgear, control panels, diesel generator enclosures, painting booths, marine engine rooms, and elevator machine rooms. It is also used in specialty vehicles, mobile telecom shelters, and offshore control cabinets where full room flood systems are not feasible. The tube can be routed around cables, bus bars, and battery racks, providing localized suppression that avoids flooding adjacent equipment.
For a 42U server rack, one 2 kg device protects the entire rack, with the tube routed along the cable arms. For a battery energy storage cabinet, two devices may be needed, one per battery module. For an electrical switchgear panel, the tube is routed around the bus bars and contactors. For a diesel generator enclosure, the tube protects the turbo and fuel filter area. KITOZER offers larger 3 kg and 6 kg devices for bigger enclosures, and a solenoid release version that integrates with the building fire alarm system.
Key Advantages
The tube detects and discharges directly at the fire point in under 5 seconds, far faster than a conventional smoke detector plus panel plus nozzle sequence. The system requires no external power, no detectors, and no commissioning wiring, which reduces installation cost and eliminates single-point failures in the fire alarm system. The agent is clean and non-conductive, so it is safe for live electrical equipment. KITOZER offers the device with FM200, FK-5-1-12, or perfluorohexane agent options to match the customer environmental policy, and supplies the tube pre-cut to length.
Because the tube bursts at the fire point, the agent is delivered directly to the source rather than flooding the whole room, which minimizes agent cost and post-discharge cleanup. The system works independently of the building fire alarm, so it remains available even if the alarm panel is damaged by the fire. The small cylinder can be mounted inside or immediately outside the enclosure, keeping the protected volume small and agent concentration high. KITOZER provides a 3-year warranty on the cylinder and a 1-year warranty on the tube.
Installation and Maintenance Recommendations
Mount the cylinder outside the protected enclosure where it is accessible for inspection, and route the detection tube around the highest-risk components using the supplied clips, avoiding sharp bends tighter than 50 mm radius. Keep the tube away from moving parts and hot surfaces that could cause false bursting. Check cylinder pressure gauge monthly and weigh the cylinder annually; refill or replace after any burst. Inspect the tube surface annually for abrasion or UV damage, and replace the tube every 5 years as a precaution.
When routing the tube, leave a minimum 100 mm gap from hot components such as heat sinks and transformers, because ambient heat can age the tube prematurely. Secure the tube with plastic clips every 300 mm, so it does not sag and touch moving parts. After installation, perform a manual release test by pulling the lever, confirming agent discharges through the tube. Keep a spare cylinder and tube on site, because the device must be replaced after any discharge. KITOZER recommends a 5-year replacement cycle for the cylinder, because the valve seals age over time.
Price
From $480 per device filled. Contact +86 13922289957 for tube-based extinguisher pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com