Table of Contents
ToggleProduct Overview
The KITOZER tube-based fire extinguishing device is a self-actuating, pre-piped fire suppression system that uses a polymer detection tube routed directly around protected equipment to sense and extinguish incipient fires without any external power supply or fire alarm panel. When the tube contacts flame, it bursts at the hottest point, automatically opening the cylinder valve through stored pressure and releasing the clean agent through the burst point directly onto the fire. This passive, independent design makes the tube-based device ideal for protecting electrical enclosures, battery cabinets, server racks, and engine compartments where installing a full gas system is impractical.
Technical Specifications
Cylinder 2 kg FM200 or perfluorohexane agent, storage pressure 2.5 MPa nitrogen, cylinder material 34CrMo4 steel, detection tube nylon reinforced polymer 8 mm OD, tube length up to 6 meters, activation temperature 170 degrees Celsius burst, manual release lever, pressure gauge, solenoid release option 24V DC for remote alarm integration, mounting bracket steel, net weight 4.5 kg, CCCF certified, GB 29550. Operating temperature minus 20 to 50 degrees Celsius, response time under 5 seconds.
Application Scenarios
This device protects equipment enclosures and small spaces such as server racks, UPS cabinets, battery energy storage cabinets, electrical switchgear, control panels, diesel generator enclosures, painting booths, marine engine rooms, and elevator machine rooms. It is also used in specialty vehicles, mobile telecom shelters, and offshore control cabinets where full room flood systems are not feasible. The tube can be routed around cables, bus bars, and battery racks, providing localized suppression that avoids flooding adjacent equipment.
Key Advantages
The tube detects and discharges directly at the fire point in under 5 seconds, far faster than a conventional smoke detector plus panel plus nozzle sequence. The system requires no external power, no detectors, and no commissioning wiring, which reduces installation cost and eliminates single-point failures in the fire alarm system. The agent is clean and non-conductive, so it is safe for live electrical equipment. KITOZER offers the device with FM200, FK-5-1-12, or perfluorohexane agent options to match the customer environmental policy, and supplies the tube pre-cut to length.
Installation and Maintenance Recommendations
Mount the cylinder outside the protected enclosure where it is accessible for inspection, and route the detection tube around the highest-risk components using the supplied clips, avoiding sharp bends tighter than 50 mm radius. Keep the tube away from moving parts and hot surfaces that could cause false bursting. Check cylinder pressure gauge monthly and weigh the cylinder annually; refill or replace after any burst. Inspect the tube surface annually for abrasion or UV damage, and replace the tube every 5 years as a precaution.
Price
From $480 per device filled. Contact +86 13922289957 for tube-based extinguisher pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com