Table of Contents
ToggleProduct Overview
The KITOZER 300 L two-phase immersion cooling system uses a low-boiling-point fluorinated fluid that vaporizes when it contacts hot components, condenses on a cooled coil near the tank rim, and drains back by gravity. This phase-change process absorbs heat at a nearly constant temperature, which keeps GPU and CPU junction temperatures extremely uniform even under full 24/7 load. The tank is fabricated from stainless 316 to resist chemical attack from fluorinated fluids, and the lid includes a condenser coil plumbed to the facility CDU. Because the fluid boils at around 50 C, the system accepts warm primary water from a dry cooler with no chiller, delivering industry-leading free-cooling hours per year.
Technical Specifications
Tank volume 300 L, working fluid 180 L (fluorinated fluid density 1.6 g/cm3). Outer dimensions 1100 x 900 x 1100 mm, internal basket 900 x 700 x 500 mm. Material stainless 316, welded and pickled. Lid aluminum with EPDM gasket and safety interlock. Condenser coil stainless 316 tube rated 60 kW at 10 K delta T, primary DN32. Fluid boiling point 50 C at 1 atm, operating temperature 45 to 55 C. Sensors PT100 fluid and vapor space, pressure transducer, level, leak, and conductivity. Controller 5 inch HMI, Modbus TCP, dry contacts, and fluid-level makeup valve. Power 230 V single phase, 0.4 kW (controls only, no pump). Empty weight 120 kg, filled weight 410 kg. Compatible fluids include engineered fluorinated dielectrics of 40 to 60 C boiling point.
Application Scenarios
Two-phase systems are chosen for the most power-dense AI and HPC racks where single-phase fluid temperature would otherwise force server fans back on. Target workloads include GPU training clusters, Bitcoin mining at the edge, defense and aerospace simulation racks, and quantum computing support electronics. The constant-temperature boiling process also suits precision test equipment that needs tightly controlled thermal environments.
Advantages and Features
Phase-change heat transfer is one order of magnitude more effective than single-phase convection, so chips that run at 85 C in air or 65 C in single-phase oil hold at 55 C in two-phase. No circulation pump is required, which removes a maintenance item and a failure point. Warm primary water enables chiller-less operation in most climates. The stainless 316 construction and fluorinated fluid are chemically stable over decades, with negligible degradation. Low vapor pressure at operating temperature means minimal makeup fluid loss.
Installation and Maintenance
Position the tank on a level, chemical-resistant floor with capacity for 500 kg. Connect DN32 primary loop to the CDU or dry cooler, plug in control power, and pour the pre-vetted fluorinated fluid through the filtered fill port. Ventilation hood above the tank should capture any minor vapor during lid opening. Maintenance: monthly fluid level check and auto top-up, quarterly condenser coil visual inspection, annual fluid sample for moisture and acidity, and biennial gasket replacement. KITOZER provides a closed-loop fluid recycling program for end-of-life fluid.
Price
From $24,800/system excluding fluid. Contact +86 13922289957 for two-phase immersion quotation.