Table of Contents
ToggleProduct Overview
KITOZER Type 1+2 combined surge protective device 100kA 385V is installed at the building service entrance to withstand direct lightning flash impulse current (10/350 microsecond) and also suppress switching surges. The spark gap based Type 1 stage discharges high-energy direct lightning current, while the downstream varistor Type 2 stage clamps residual voltage for sensitive loads. This combined unit removes the need for two separate SPD cabinets, saving space and installation labor. It is the standard first line of defense for structures equipped with air-termination systems, including high-rise buildings, substations, factories, data centers, and stadiums.
Technical Specifications
Configuration: 4-pole 3+NPE. Uc: 385V AC. Type 1 impulse current Iimp (10/350 microsecond): 25 kA per pole. Type 2 maximum discharge current Imax (8/20): 100 kA per pole. Voltage protection level Up: not more than 2.0 kV. Response time: 100 nanoseconds. Follow current extinguishing: 50 kA rms. Integrated gas-tight spark gap. Remote signal contact: NO/NC. Mounting: 35mm DIN rail. Housing: UL94-V0. Operating temperature: minus 40C to plus 80C. Short-circuit withstand: 100 kA. Certifications: IEC 61643-11 Class I+II, CE. Brand: KITOZER. Warranty: 5 years.
Application Scenarios
This SPD is mandatory at the service entrance of any structure with lightning protection system per IEC 62305. It is used in high-rise office towers, hospital main switchrooms, data center incomer cabinets, industrial plant substations, petrochemical plants, water treatment stations, large retail centers, and public infrastructure. It is also required at the boundary between overhead and underground supply lines, where induced surges from nearby lightning strikes are severe. The unit is typically paired with downstream Type 2 SPDs at each distribution floor and Type 3 units at sensitive load outlets.
Advantages and Features
The combined Type 1+2 design reduces cabinet space, cable length, and commissioning cost compared with two separate devices. The spark gap stage handles 25 kA 10/350 microsecond impulse without thermal runaway, which is essential for direct flash exposure. The varistor stage provides low Up for downstream electronics. KITOZER SPDs include an integrated backup disconnector that safely opens under short-circuit failure. The visual window shows green when healthy and red when replacement is needed. The remote contact allows BMS monitoring. The housing is UV stabilized for outdoor cabinet installation. Compared with open spark gap units, this enclosed design prevents flame escape and meets stricter fire safety requirements in occupied buildings.
Installation and Maintenance Recommendations
Install immediately after the main incomer breaker, with leads as short as possible, total loop length under 0.5m. Use 25mm2 copper for phase and neutral, 35mm2 for PE. Coordinate with upstream gG fuse or breaker rated 125A. Connect the remote alarm to BMS. Perform visual inspection every six months and full leakage current test annually. Replace modules if the indicator turns red or leakage exceeds 200 microamp. After a nearby lightning strike, inspect the SPD visually and record the surge counter if fitted. Replace the complete set after 10 years. For coastal or dusty sites, clean the housing and terminals every year. KITOZER provides coordination calculation between Type 1+2, Type 2, and Type 3 stages.
Price
From $220 per unit. Contact +86 13922289957 for service entrance SPD quotation.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com