KITOZER Type 2 SPD Surge Protector 40kA 275V For LV Distribution

KITOZER Type 2 surge protective device (SPD) is a DIN rail mounted lightning surge arrester installed at low voltage distribution boards to protect downstream equipment from switching surges and indirect lightning induced overvoltage. The 40kA 275V rating is the most commonly specified Type 2 SPD for commercial building mains boards, sub distribution cabinets, UPS input panels, and small data center PDU feeds. Using high energy metal oxide varistor (MOV) technology with a thermal disconnect indicator, the SPD clamps surge voltage to below 1.5kV and diverts up to 40kA per pole into the earth network. KITOZER offers single phase and three phase versions, with optional remote alarm contact for building management system monitoring.

Product Overview

Surge voltage on low voltage supply lines is caused by lightning strikes nearby, capacitor bank switching, motor starting, and utility reclosure events. Even a few kilovolts can damage server power supplies, PLC modules, and telecommunication boards. The KITOZER Type 2 SPD installs in parallel with the load and acts as a pressure relief valve for voltage spikes: under normal voltage it is high impedance, but when voltage exceeds the protection level it switches to low impedance and shunts the surge current to earth. The plug in MOV module design allows replacement without rewiring the cabinet, and the visual red flag indicates when the module has aged and needs replacement.

Technical Specifications

Type: Class II per IEC 61643 part 11. System voltage: 230/400V AC. Maximum continuous voltage Uc: 275V AC. Nominal discharge current In: 20kA (8 by 20 microsecond). Maximum discharge current Imax: 40kA per pole. Voltage protection level Up: 1.5kV. Response time: less than 25 nanoseconds. Follower current: follow current limiting. Thermal disconnect: built in, red visual indicator. Remote signal contact: optional dry contact, 250V 0.5A. Mounting: 35mm DIN rail. Poles: 1P, 1P+N, 3P, 3P+N options. Wire cross section: 6 to 35mm2. Standards: IEC 61643 part 11, EN 61643, GB 18802. Operating temperature: minus 40 to plus 85 degrees Celsius. KITOZER brand, 5 year warranty.

Applications

The KITOZER Type 2 SPD is installed at the main low voltage distribution board of every commercial building, hospital, school, and factory. It is also installed at sub distribution boards in each floor or each department to provide staged protection. In data centers it sits on the input side of each UPS and PDU. In telecom rooms it protects the AC supply to rectifiers and battery chargers. In industrial plants it protects PLC cabinets, servo drives, and instrumentation power supplies. In photovoltaic installations a Type 2 SPD is fitted on the AC side of the inverter. For sites exposed to direct lightning, a Type 1 SPD is added at the main intake and the Type 2 at the sub board, forming a coordinated two stage protection scheme.

Advantages

The plug in MOV module design means replacement takes under two minutes without turning off the supply to critical loads. The visual indicator plus remote alarm lets maintenance teams know when the SPD has absorbed a surge or aged out, instead of discovering damage after an equipment failure. Low Up of 1.5kV protects sensitive modern switch mode power supplies that are damaged by surges above 2kV. DIN rail mounting fits standard distribution boards without custom brackets. The 40kA rating handles most indirect lightning events without failure. Coordinated Type 1 plus Type 2 arrangement provides reliable protection for buildings in high lightning density regions. KITOZER SPDs comply with IEC 61643 and carry CE, allowing use on international projects.

Installation and Maintenance

Install the SPD as close as possible to the incoming supply terminals, with short leads under 0.5m total loop length to minimize inductive voltage. Connect line and neutral to the SPD terminals with 16mm2 minimum copper wire, and earth to the local bonding bar with 16mm2 green yellow wire. Fit a downstream backup protector (gG fuse 32A or specific SPD back-up breaker) to isolate the SPD in case of short circuit after MOV failure. After installation, record the initial indicator state green. Inspect quarterly for indicator color; red means replace the module. If the remote alarm contacts the BMS, investigate the alarm event log to identify surge activity. Replace modules after a major lightning storm even if indicator is still green, because repeated surges degrade MOV energy capacity. Keep two spare modules in the spares cabinet.

Available Models and Custom Service

KITOZER stocks the 40kA 275V Type 2 SPD in 1P, 1P+N, 3P, and 3P+N configurations for immediate dispatch. Lower 20kA versions are specified for light commercial distribution, while higher 65kA and 80kA versions are used in high lightning density regions. Uc options include 275V for 230V systems, 320V for 277V systems, and 385V for 400V systems. KITOZER can supply the SPD with remote alarm contacts pre-wired to a terminal block, and with event counter for critical installations. Replacement MOV modules are stocked separately so after a surge event the maintenance team only swaps the module, not the whole unit. Coordination study with upstream Type 1 SPD is available on request.

Price

From $45 per pole for 1P 40kA 275V module. 3P+N complete unit from $165. Replacement MOV modules from $35. Contact +86 13922289957 for SPD coordination study and project pricing.