ToggleProduct Overview
KITOZER 30kVA UPS maintenance bypass cabinet enables safe servicing of a UPS system without interrupting the critical load. By switching the load from the UPS output to a utility bypass source, technicians can isolate the UPS for repair, battery replacement, or firmware upgrade while servers and storage remain powered. The cabinet uses mechanically interlocked breakers to prevent backfeeding between UPS output and bypass source. A front panel mimic diagram shows the current power path, and terminals for remote signaling integrate the bypass into the building management system.
Technical Specifications
Rated power 30kVA, three phase 400V input and output. Inputs: utility bypass, UPS output, output to load. Mechanically interlocked breakers 63A. LED mimic diagram showing UPS path, bypass path, and fault states. Terminals for remote alarm and run status. Protection class IP20. Floor standing cabinet 600x800x400mm. CE and IEC 60950 certified. KITOZER brand, 5 year warranty. Compatible with most 10 to 40kVA online double-conversion UPS brands.
Application Scenarios
The bypass cabinet is deployed with every critical UPS installation in data centers, server rooms, industrial control rooms, and medical facilities. It allows planned maintenance without scheduling downtime windows, which is essential for 24/7 operations. In colocation and multi-tenant facilities, the bypass cabinet is standard equipment because UPS vendors require a safe way to work on the unit. It is also used in disaster recovery sites and broadcast rooms where any interruption causes revenue loss.
Advantages and Features
The core benefit is uninterrupted load power during UPS service. Mechanical interlocks prevent human error, such as closing both UPS and bypass breakers at the same time. The mimic diagram removes ambiguity about the power path. Remote signaling tells the BMS whether the load is on UPS or bypass, which affects energy metering and alarm logic. Compact cabinet fits next to the UPS in a standard room. KITOZER builds the cabinet with input and output terminals pre-wired to the breaker, reducing on-site labor.
Installation and Maintenance Recommendations
Install the cabinet between the UPS output and the load distribution panel, with separate feeds for utility bypass. Verify phase rotation and voltage match before closing any breaker. Train operators on the sequence: first close bypass breaker, then open UPS output breaker, then service the UPS. Reverse the sequence to return to normal. Test the bypass transfer annually under known load. Keep the mimic lamps working, and replace any failed lamp. Inspect breaker terminals every two years for tightness.
Price
From $1,280 per cabinet including interlocked breakers and mimic panel. Contact +86 13922289957 for bypass cabinet pricing.