KITOZER UPS Bypass Cabinet: 30kVA Maintenance Bypass

Product Overview

KITOZER 30kVA UPS maintenance bypass cabinet allows technicians to isolate an uninterruptible power supply for service while the critical load continues to run directly from utility power. The cabinet integrates a manual maintenance bypass switch, an input breaker, an output breaker, and an optional input/output measurement meter in a single floor-standing enclosure. The interlocked mechanical design ensures that the load can never be simultaneously connected to the UPS output and the bypass source in an unsafe sequence, and a clearly labeled operating sequence plate guides the electrician through transfer. The cabinet is matched to 10kVA to 30kVA single-module UPS systems used in small server rooms, network closets, and branch office IT environments.

Technical Specifications

Rated power 30kVA, three phase input single phase output or three phase output option, rated current 60A output, input breaker 63A, output breaker 63A, maintenance bypass switch interlocked rotary handle, voltage 400V input 230V output 50/60Hz. Optional LCD meter displays input voltage, output voltage, load current, and frequency. Emergency power off input terminals. Protection IP20, dimensions 600mm wide by 600mm deep by 1600mm high, weight 90kg. Operating temperature 0C to 40C. CE, IEC 60950, KITOZER brand, five year warranty.

Application Scenarios

This bypass cabinet is placed between the UPS and the critical load bus in small data centers, branch offices, retail headquarters, and medical imaging rooms. It becomes essential whenever the UPS needs cooling fan replacement, capacitor replacement, firmware upgrade, or warranty service, because the load can remain online while the UPS is powered down. Integrators also specify it in projects where the customer requires scheduled UPS maintenance without service-level-agreement penalties. The cabinet is commonly paired with online double-conversion UPS units from 10kVA to 30kVA.

Advantages and Features

The interlocked rotary switch prevents operator error, which is the leading cause of load dropout during bypass operations. The integrated breakers remove the need to buy separate distribution gear, reducing panel space and wiring errors. The optional meter gives immediate visibility of load current and voltage, helping the operator confirm that the load is healthy before transferring to bypass. The floor-standing cabinet arrives pre-wired, so site labor is limited to connecting the UPS input, UPS output, and load cables. The unit also supports remote EPO integration, shutting down the load in an emergency without opening the cabinet.

Installation and Maintenance

Position the cabinet next to the UPS and route cables between the two units using flexible copper braids or heavy cable lugs. Follow the operating sequence plate on the door: close bypass switch, verify bypass voltage, open UPS output, shut down UPS. Reverse the sequence when returning to UPS. Torque all power connections to the printed value and recheck after one month. Maintenance consists of annual visual inspection, breaker trip test, and contact resistance measurement on the bypass switch. Keep the cabinet interior dry and ventilated, and do not store objects inside the enclosure.