The KITOZER UPS monitoring module is an external communication adapter that converts UPS serial, USB, or dry-contact interfaces into standard SNMP and Modbus TCP, allowing UPS status to be integrated into data center DCIM, BMS, and NMS platforms. Many UPS units ship with only a basic USB port and proprietary software, which is difficult to integrate into enterprise monitoring. The KITOZER module bridges this gap, providing real-time visibility into UPS input voltage, output voltage, load percentage, battery capacity, battery runtime, internal temperature, and alarm events over the network.
The module supports multi-vendor UPS protocols, including common Megatec serial protocol, and dry-contact mapping for legacy UPS units that lack digital communication. It can be connected to one or two UPS units simultaneously, making it cost-effective for small server rooms with parallel redundant UPS. The built-in web server displays a live dashboard with battery state, load bar, and event log, and it can send email, SMS, and SNMP trap notifications when the UPS transfers to battery or battery capacity drops below a threshold.
Table of Contents
ToggleProduct Overview
The module is a small DIN-rail or wall-mount device with two serial ports, one USB port, one Ethernet port, and four dry contact inputs. Power is supplied by 9 to 24 VDC. A terminal block on the rear accepts UPS serial cables and dry contact signals. The front panel LED indicates power, network, and UPS communication status. The module can be mounted inside the UPS cabinet or in an adjacent monitoring enclosure.
Technical Specifications
Interfaces: 2 x RS232 serial, 1 x RS485, 1 x USB, 1 x Ethernet 10/100, 4 x dry contact inputs. Supported protocols: Megatec serial, generic Modbus RTU UPS, dry contact mapping. Network: SNMP v1/v2c/v3, Modbus TCP, HTTP, HTTPS, email, SMS gateway. UPS parameters: input voltage, output voltage, output load, battery capacity, battery runtime, internal temperature, bypass status, alarms. Power: 9 to 24 VDC, 300 mA. Operating temperature: -10 to +60 C. Enclosure: ABS, IP30, DIN or wall mount. Certifications: CE, FCC, RoHS. KITOZER warranty: 2 years.
Application Scenarios
This module is used in small server rooms, mid-size data centers, retail IT closets, industrial control rooms, and hospital electrical rooms. It is particularly valuable for facilities that have mixed-vendor UPS fleets, because the KITOZER module normalizes data from different UPS models into a single register map. In a data center, every UPS is connected to a KITOZER module, and the central DCIM platform pulls status every 30 seconds. In a hospital, the module triggers an automatic shutdown of connected servers through the built-in shutdown agent when battery runtime drops below a defined threshold.
Advantages and Features
The main advantage is vendor-agnostic UPS integration. Rather than relying on each UPS manufacturer proprietary software, the KITOZER module provides one consistent interface. The SNMP v3 support meets cybersecurity requirements for government and enterprise networks. The built-in graceful shutdown agent for Windows and Linux servers prevents data corruption during extended outages. The module also supports dry contact input for legacy UPS units that have no digital port, extending the life of older equipment.
Installation and Maintenance Advice
Connect the serial cable to the UPS communication port, configure the UPS protocol through the web interface, and assign a static IP address. Test the module by simulating a power outage: verify that the UPS transfers to battery, the module reports it, and the shutdown agent sends alerts. Update the module firmware annually, and keep a record of which UPS model is connected to which module IP. For battery monitoring, schedule annual battery impedance tests and replace batteries when runtime drops below 50 percent of nameplate.
Typical Deployment Configuration
In a data center with mixed-vendor UPS systems, every UPS is connected to a KITOZER UPS monitoring module via serial or USB cable. The module polls the UPS every 5 seconds and publishes status over SNMP v3 to the central DCIM platform. If the UPS transfers to battery or battery capacity drops below 30 percent, the module triggers an email to the facilities team, an SMS to the on-call engineer, and a webhook to the IT automation system. The built-in graceful shutdown agent also sends a command to connected servers, allowing them to shut down cleanly before the battery runs out. In a hospital, the module monitors UPS units in the IT room, the operating theater, and the laboratory, and alarms are escalated to the building control room. For legacy UPS units that have no digital port, the dry contact inputs map relay signals such as battery low, fault, and bypass into the same monitoring platform. KITOZER provides a free MIB file and register map for fast integration, and engineering support is available for unusual UPS protocols.
Price
From $128 per module. Contact +86 13922289957 for multi-UPS project pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com