KITOZER 100kVA UPS parallel cabinet allows two 50kVA UPS modules to operate in parallel for redundancy and capacity scaling. With parallel operation, load is shared evenly between units, and if one UPS fails the other takes the full load without interruption. The cabinet houses the parallel bus, output breaker, synchronization wiring, and maintenance bypass, simplifying installation and reducing cabling errors. It is designed for medium data centers, industrial plants, and commercial facilities that need N+1 redundancy without the cost of a single large UPS.
Parallel operation provides both redundancy and scalability. N+1 redundancy means that if one UPS fails, the other carries the load, and the failed unit can be serviced while the system remains online. As capacity grows, additional UPS modules can be added up to the parallel limit, providing pay-as-you-grow investment. This model matches phased IT expansion, where load increases over several years and a single oversized UPS would waste capital in early years.
Technical Specifications
Rated total power 100kVA (2 x 50kVA), three phase 400V. Input: two UPS feeds, utility bypass. Output: single bus to load. Output breaker 160A. Parallel synchronization board for load sharing within 5 percent. Maintenance bypass interlocked. LED mimic showing each UPS status, load share, and bypass position. Remote monitoring via dry contacts and Modbus. IP20 floor cabinet 800x1000x600mm. CE, IEC 62040. KITOZER, 5 year warranty. Compatible with KITOZER and third-party 50kVA online UPS.
The parallel bus uses copper bars sized for 160A continuous, with short-time withstand of 35kA for 1 second. The synchronization board measures voltage, frequency, and phase of each UPS and adjusts load share within 5 percent. The maintenance bypass uses mechanically interlocked breakers, preventing simultaneous UPS and bypass closure. Remote signaling includes each UPS healthy, load share percentage, bypass active, and common alarm. The cabinet is powder-coated steel with lockable front and rear doors. Operating temperature range is 0 to 40 degrees Celsius.
Application Scenarios
Parallel cabinets are used in facilities that cannot afford single-UPS downtime but also cannot justify a huge standalone unit. Typical sites include enterprise data centers, hospital IT rooms, manufacturing control rooms, and broadcast facilities. N+1 redundancy means that one UPS can be serviced while the other carries the load. As capacity grows, additional UPS modules can be added up to the parallel limit. This pay-as-you-grow model matches phased IT expansion.
Specific deployments include corporate data centers with 100 to 200 racks, hospital IT rooms supporting electronic medical records, and manufacturing plants with automated production lines. In financial trading rooms, parallel UPS ensures that trading continues even if one unit fails. In government facilities, N+1 redundancy is required for secure rooms. The cabinet is also used in disaster recovery sites and broadcast production suites. It is compatible with most major UPS brands, making it a flexible solution for mixed-vendor environments.
Advantages and Features
Parallel operation gives both redundancy and scalability. Load sharing ensures neither unit is overloaded during normal operation. The cabinet pre-wires synchronization cables, eliminating complex field wiring. The mimic panel shows which UPS is online, load share percentage, and whether the system is on bypass. Maintenance bypass allows isolation of one UPS at a time. Modbus integration lets operators monitor load share and alarm status remotely. KITOZER cabinet is sized to fit through standard doorways.
Additional benefits include reduced installation time, lower capital cost, and future scalability. Because the cabinet is pre-wired, on-site labor is reduced by 50 percent compared with field-built parallel systems. The mimic panel is intuitive, with color-coded LEDs for each path. Remote monitoring via Modbus integrates the parallel system into BMS or DCIM. The cabinet ships fully assembled, with a test report and wiring diagram. KITOZER provides factory training on parallel system operation and maintenance.
Installation and Maintenance Recommendations
Place the cabinet between the two UPS units and the output distribution panel. Connect parallel communication cables per manual, using shielded cable and proper grounding. Verify load share balance under 50 percent and 100 percent load during commissioning. Test redundancy by switching off one UPS and confirming the other takes over without load interruption. Annual maintenance includes testing breakers, checking parallel communication, and verifying load share. Keep spare communication boards on site.
For safe operation, ensure that both UPS units are the same model, rating, and firmware version before parallel operation. Wire the utility bypass to a different feeder than the UPS inputs, providing true redundancy. Test the maintenance bypass transfer during commissioning. Label breakers clearly with the transfer sequence. KITOZER recommends annual inspection of breaker terminals, synchronization board, and communication cables. Keep a digital log of load share values and alarm events for future analysis.