The KITOZER UPS parallel cabinet enables multiple UPS modules to operate in parallel, sharing load current and providing redundancy for critical loads. The cabinet houses the parallel communication cables, output busbar, and control logic that synchronize the UPS units so they share the load equally and take over seamlessly if one module fails. Parallel redundancy is a standard architecture in data centers and critical infrastructure, because it allows capacity to be added in modules and provides N plus 1 redundancy without a single point of failure. KITOZER builds the parallel cabinet as a floor-standing assembly matched to the UPS rating and number of modules.
Table of Contents
ToggleTechnical Specifications
Configuration: 3 x 200kVA UPS in parallel, total capacity 600kVA with N plus 1 redundancy (400kVA critical load). Rated voltage 400V three phase, rated current up to 900A. Parallel synchronization via fiber or dedicated parallel bus, load sharing accuracy within plus or minus 5 percent. Output busbar rated for total system current. Input and output breakers per UPS module, with mechanical interlocks. Cabinet IP20, floor standing. Conforms to IEC 60947. Compatible with KITOZER three-phase UPS systems. KITOZER, 5 year warranty.
Applications
The KITOZER parallel cabinet is used in medium and large data centers, hospital IT departments, and industrial process control rooms where downtime is unacceptable. By running three 200kVA modules in parallel, the system continues to support the full critical load even if one module fails, and maintenance can be performed on one module at a time while the others carry the load. This is far more resilient than a single large UPS, which would take the whole load down if it faults.
Parallel architecture also supports incremental growth: a facility can start with two modules and add a third later as load grows, without replacing the whole UPS. In modular data hall designs, each hall has its own parallel UPS row fed from the parallel cabinet. The cabinet is also used to combine UPS units of the same rating from the same family, because parallel operation requires identical control firmware and communication protocols.
Key Advantages
Redundant parallel operation removes the single-point-of-failure risk of a single large UPS. Load sharing ensures no module is overloaded while another is lightly loaded, which prolongs battery and power module life. Hot-swap capability allows a faulty module to be isolated and replaced without shutting down the critical load. KITOZER preconfigures the parallel cabinet at the factory, so on-site work is limited to connecting the UPS modules, batteries, and output distribution.
The parallel system reports per-module load, battery status, and fault alarms to the DCIM or building management system via Modbus or SNMP. Operators can see at a glance which module carries what load and which module has tripped. Standardized cabinet dimensions fit typical data center power rows, and busbar connections are designed for easy expansion when additional modules are added.
Installation and Maintenance
Install the parallel cabinet on a level floor with adequate clearance for cable entry and module access. Connect each UPS module to its dedicated input and output breaker in the cabinet, and run the parallel communication cables as specified. Ensure the earthing system is solid and that the neutral is treated consistently across all modules. Commission the system by bringing modules online one at a time and verifying load sharing.
During preventive maintenance, verify that each module shares load evenly, check parallel cable connections, and inspect output busbar tightness. Test redundancy by tripping one module and confirming the others pick up the load without disturbance. Keep spare power modules and parallel communication cards on site. Never mix UPS models or firmware versions in a parallel system, because load sharing depends on identical control behavior.
KITOZER supplies the parallel cabinet in configurations from two modules up to eight modules, with module ratings from 10kVA to 400kVA each. It can be built for N plus 1 redundancy or for pure capacity expansion, and the busbar rating is chosen to carry the total system current with margin. When ordering, specify the number of UPS modules, each module kVA, the system voltage, and whether the parallel link is copper busbar or cable. KITOZER confirms that the UPS modules share the same firmware revision and control card type before shipping, because parallel operation depends on identical behavior. The cabinet is factory-tested for load sharing and redundancy transfer before shipment. Spare parallel communication cards and module breakers are recommended as critical spares. KITOZER also supports the design of the upstream and downstream switchgear so that fault levels and discrimination are correct. For facilities phasing in capacity, the cabinet can be pre-drilled for future module positions, allowing additional UPS units to be added later without replacing the enclosure.