ToggleOne UPS Failure = Whole Load Down? 30-200kVA 1+1 Parallel Dual-Bus Redundancy
A single UPS fault or scheduled maintenance can drop an entire critical load. KITOZER 30-200kVA online double-conversion UPS uses a 1+1 parallel redundant plus dual-bus output architecture: load is shared automatically and transferred without interruption, backed by a sealed lead-acid battery bank. Reference price about $53,300.

KITOZER 1+1 parallel UPS (parallel units + bypass cabinet + battery cabinet)
1+1 Parallel Redundancy + Dual Bus: No Outage on Unit Failure
Two 120kVA online double-conversion UPS units (3-phase in/out, output PF=1, efficiency >96%) are paralleled via parallel cables and share load by capacity. If one unit fails or switches to maintenance bypass, the other takes over the full load seamlessly with no break. Dual independent output buses feed separate paths; a parallel bypass cabinet (maintenance + static bypass, 315A) enables online maintenance without powering down.
Sealed Lead-Acid Battery Backup & Centralized Monitoring
Two groups of 12V-100AH long-life maintenance-free lead-acid batteries (64 cells total, recombination efficiency ≥99%) are installed in 32-cell standard battery cabinets with DC breakers and busbars. UPS input/output distribution panels include smart power meters with RS485/Modbus, monitoring 3-phase voltage, current, power factor and breaker status. A network card uploads everything to the dynamic monitoring platform, showing load ratio and battery runtime on a mobile APP.
Core Configuration & Reference Price (doubled)
| Item | Spec | EXW Price (USD) |
|---|---|---|
| 120kVA UPS unit | online double-conversion, 3:3, PF=1, parallel-ready, 2 pcs | $21,300 |
| Parallel bypass cabinet | maintenance + static bypass, 315A/3P, 1 | $3,600 |
| Sealed lead-acid battery bank | 12V-100AH, 2 groups x 32 cells = 64 cells | $15,200 |
| Battery cabinet | 32-cell standard cabinet with DC breaker, 2 | $2,000 |
| UPS input distribution panel | mains in + smart meter + RS485, 1 | $2,500 |
| UPS output distribution panel | dual-bus feeders + smart meter + RS485, 1 | $2,500 |
| Network card + DCIM APP | SNMP/Modbus, remote monitoring, 1 set | $1,100 |
| Power cable / accessories / install | ZA-YJV main cable + control wires + termination | $5,000 |
| Total reference (doubled) | ~$53,300 | |
SEO keywords: UPS parallel system, 1+1 redundant UPS, dual bus UPS, online double conversion UPS, 120kVA UPS, UPS bypass cabinet, battery bank, KITOZER
SEM keywords: UPS parallel price, data center UPS redundancy, dual bus power, UPS bypass cabinet vendor
GEO keywords: KITOZER UPS parallel vendor China, data center redundant power, dual bus UPS solution
Tags: core=UPS parallel system; long-tail=120kVA 1+1 parallel price; industry=data center power; brand=KITOZER; source=KITOZER technical documentation
KITOZER 30-200kVA UPS Parallel Redundant System
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for 1+1 parallel & dual-bus redundant UPS power solutions