KITOZER
KITOZER

KITOZER Vacuum Circuit Breaker: 10kV 630A For Distribution Switchgear

The KITOZER 10kV vacuum circuit breaker is a medium-voltage switching and protection device designed for the control and safeguarding of distribution transformers, feeder cables, and industrial busbars within urban and rural power distribution networks. At the heart of the breaker is a sealed vacuum interrupter that quenches the arc with exceptional speed and silence, eliminating the arc-gas and contact erosion problems associated with older air-break or oil-filled designs. A stored-energy spring operating mechanism stores and releases mechanical energy reliably, giving consistent closing and tripping behavior across the full duty cycle. Because the arc is confined inside a sealed ceramic vacuum bottle, the breaker runs cleanly indoors and requires far less routine servicing than legacy alternatives. This makes the KITOZER vacuum breaker a natural choice for industrial substations, commercial building incoming panels, hospital campuses, and renewable energy collection stations where dependable medium-voltage protection cannot be compromised.

Technical Specifications

Rated voltage 12kV, rated frequency 50Hz, rated normal current 630A, rated short-circuit breaking current 20kA, short-time withstand current 20kA for 4 seconds, peak withstand current 50kA, rated operating sequence O-0.3s-CO-180s-CO. The vacuum interrupter uses a high-alumina ceramic envelope with copper-chromium contacts. The spring operating mechanism is motor-charged at DC 110V or 220V with manual backup, and supports shunt trip, under-voltage release, and auxiliary contact signaling. Ambient operating range is minus 25 to plus 40 degrees Celsius, installation altitude up to 1000m without derating, and the breaker conforms to IEC 62271-100 and GB 1984 standards.

Applications

The KITOZER 10kV vacuum circuit breaker is deployed inside ring main units, metal-clad withdrawable switchgear, and feeder automation panels across a wide range of industries. In manufacturing plants it protects medium-voltage motor feeders and furnace transformers. In commercial complexes and hospital campuses it safeguards 10/0.4kV distribution transformers feeding essential loads. In data center utility switchrooms it provides the primary protection between the medium-voltage incomer and the step-down transformer feeding the low-voltage switchboard. It is also widely used in photovoltaic and wind power collection substations, pump stations, water treatment plants, and mining distribution systems where frequent switching operations are part of the normal duty cycle.

When fitted into withdrawable switchgear, the breaker truck can be racked out to the test or isolated position while the main busbar remains energized. This allows maintenance staff to inspect contacts and the interrupter without de-energizing the entire bus, which is a major advantage for facilities that cannot afford extended shutdowns. The compact frame footprint matches standard 12kV switchgear cubicles, so the breaker can be retrofitted into existing panels with minimal modification, reducing civil and electrical works during upgrade projects.

Key Advantages

The sealed vacuum interrupter delivers a long electrical and mechanical life, typically rated for up to 30,000 mechanical operations and thousands of load-current interruptions before overhaul. With no arc gas to vent and no oil to monitor, the breaker is environmentally clean and suitable for indoor switchrooms and enclosed substations. Contacts erode very slowly in vacuum, and the interrupter pressure indicator gives maintenance staff a simple health check at a glance. The spring mechanism is self-contained, does not require compressed air, and operates reliably even on low auxiliary supply voltages.

KITOZER manufactures the breaker under controlled factory conditions with routine type tests and routine production tests on every unit. Spare interrupters, coils, and contact sets are standardized across the product family, simplifying spare-parts stocking for end users and contractors. The breaker supports remote close, remote trip, and trip-circuit supervision signals, so it can be integrated into SCADA, distribution automation, and energy management systems without additional gateway hardware.

Installation and Maintenance

Install the breaker in a clean, dry, ventilated switchgear cubicle with the specified phase-to-phase and phase-to-earth clearances. Before energization, verify the primary contact alignment, torque of bolted connections, and earthing continuity. Check that the spring is correctly charged and that the closing and tripping circuits respond to both local and remote commands. Keep the cubicle free of conductive dust and corrosive gases, and maintain the recommended ambient temperature and humidity range.

Perform annual preventive maintenance: measure insulation resistance and main-circuit contact resistance, inspect the vacuum interrupter pressure window, listen for abnormal mechanical noise during open and close operations, and lubricate the mechanism linkages per the service manual. Test the shunt trip and under-voltage release under simulated fault conditions to confirm protection coordination. Store spare interrupters upright in controlled storage to preserve vacuum integrity, and replace any contact set that shows visible pitting after a major fault interruption.

KITOZER offers the vacuum circuit breaker in a range of rated currents from 630A up to 4000A and breaking currents from 20kA to 40kA, so engineers can match the device to the available fault level and load current of each feeder. The breaker can be supplied with motorized or manual spring charging, and with auxiliary contact configurations that suit the protection and control scheme of the panel. When ordering, specify the rated voltage, rated current, breaking current, operating mechanism voltage, and the required auxiliary contact count. KITOZER also supplies complete withdrawable chassis and secondary plug connectors for retrofit into existing switchgear. The breaker is factory-tested for contact resistance, insulation, and mechanical operation, and each unit ships with a test report. Spare interrupters, closing coils, tripping coils, and spring charging motors are available as standard spares, minimizing downtime during maintenance. Because the vacuum bottle is sealed for life, the breaker requires no routine gas handling and can be serviced by standard switchgear technicians with basic training. For projects requiring type test reports, CE declarations, or customized panel interfaces, KITOZER engineering supports the documentation and review process from enquiry through commissioning.

Price

From $1,850/pc. Contact +86 13922289957 for breaker quotation, rated current options, and factory lead time.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top