KITOZER VCB: 10kV 630A Vacuum Circuit Breaker For Ring Main

KITOZER 10kV 630A vacuum circuit breaker is a medium-voltage switching device designed for distribution networks, ring main units, and industrial feeder protection. The breaker uses a sealed vacuum interrupter as the arc extinction medium, so dielectric strength recovers instantly after current zero crossing and repeated switching operations remain stable over decades of service. This model is rated for 630A continuous current and 20kA short-time withstand current, making it suitable for cable feeders, transformer primaries, and motor branch circuits where frequent load switching and fault interruption are required. The breaker is factory tested for routine and short time duty cycles before shipment, ensuring that every unit arrives ready for installation without additional field adjustment.

Product Overview

The KITOZER 630A VCB adopts a withdrawable truck mounted construction that slides into a 12kV switchgear compartment, providing visible isolation when the truck is racked out. A spring charging mechanism stores energy for closing and tripping independent of auxiliary supply voltage, ensuring fault clearance even during control power dips. The vacuum interrupter is housed in a cast resin pole unit that seals internal parts against dust, moisture, and corrosive atmospheres, extending contact life and reducing routine inspection frequency. Mechanical and electrical interlocks prevent incorrect racking, closing, and earthing operations to protect both personnel and equipment. A local control panel on the truck offers close, trip, and spring charge push buttons together with red and green status indicators, while a terminal block at the rear connects to the switchgear protection relays and substation battery.

Technical Specifications

Rated voltage 12kV, rated frequency 50/60Hz, rated normal current 630A, rated short-circuit breaking current 20kA, rated short-time withstand current 20kA for 4 seconds, rated peak withstand current 50kA, rated operating sequence O-0.3s-CO-180s-CO, rated lightning impulse withstand voltage 75kV peak. Auxiliary supply options DC 110V/220V or AC 110V/220V, motor charging energy, shunt closing and shunt tripping coils, undervoltage release optional. Mechanical endurance 10,000 operations, electrical endurance 30,000 operations at rated current, protection class IP2X for the pole system, weight approximately 95kg. The interrupter contact erosion monitoring uses travel and over travel measurements taken during commissioning and each overhaul, so maintenance teams can predict end of life instead of responding to sudden failure. Standard compliance with IEC 62271-100, GB 1984, and CE marking requirements.

Applications

This breaker is widely applied in urban and rural distribution substations, industrial plant medium voltage bus tie, commercial building secondary switchgear, and renewable energy collection feeders. Typical installations include 10kV cable loop networks, transformer incoming and outgoing panels in KYN28A and XGN switchgear, motor control centers for medium voltage pumps and fans, and photovoltaic or wind farm collector circuits where fault isolation must be fast and selective. It also serves as the outgoing breaker on ring main units feeding commercial and residential load clusters. Plant engineers choose this model when the feeder load sits between 400kVA and 1000kVA transformer primaries, because the 630A rating leaves comfortable thermal margin without paying for the larger 1250A frame. In data center and hospital switchrooms, the breaker is often paired with a multifunction protection relay that provides overcurrent, earth fault, and under voltage tripping with remote trip and close contacts for the building management system.

Advantages

Vacuum arc extinction produces no gas emission and no oil handling, so the breaker is environmentally clean and suitable for indoor switchrooms with limited ventilation. The sealed pole eliminates contact oxidation and minimizes maintenance compared with air or oil breakers. Withdrawable design allows fast replacement of the truck during overhauls without de-energizing the main bus. The spring mechanism offers reliable closing even when control voltage sags, and modular auxiliary contacts support flexible protection relay wiring. Low noise during switching and no fire risk make it the preferred choice for occupied commercial buildings and underground substations. Because the vacuum interrupter has no consumable arc products, the breaker can be cycled tens of thousands of times before contact replacement, which is a major advantage in frequently switched motor and capacitor applications.

Installation and Maintenance

Mount the breaker truck on the switchgear rails, ensure primary contacts align with the bus socket, and rack in until the service position latch engages. Verify the anti-condensation heater is active before energization. Commissioning requires a contact resistance test, insulation resistance test, protection relay injection test, and mechanical operation count. Maintenance intervals of three to five years include vacuum interrupter leakage check using a power frequency withstand test, contact travel and over-travel measurement, spring mechanism lubrication, and auxiliary contact tightening. Keep the switching count log and replace the interrupter when contact erosion reaches the manufacturer limit. Spare trucks are recommended for critical substations to minimize outage time. During overhaul, inspect the opening and closing springs for deformation, check the auxiliary switch contacts for oxidation, and confirm that the anti-pumping relay blocks immediate re-close after a trip. Store spare trucks in a dry, dust free room with the heater plugged in.

Ordering and Support

When ordering, specify the rated voltage, normal current, breaking current, auxiliary supply voltage, and the switchgear model the truck will be installed in. KITOZER supplies the breaker complete with secondary terminal wiring diagrams, factory test reports, and a commissioning checklist. Spare parts kits include closing coil, tripping coil, auxiliary switch, and contact finger assembly. Technical engineers are available to support protection relay coordination drawings and switchroom layout reviews. Each breaker carries a five year warranty covering manufacturing defects, and factory acceptance tests can be witnessed at the assembly plant before shipment.

Price

From $1,480/pc. Contact +86 13922289957 for VCB quotation and factory lead time.