ToggleKITOZER KTR-SH17 Rack Shelf / Ventilated Reinforced with Cable Slot
Brand: KITOZER Series: KTR-SH17 Category: Data Center Engineering / Rack Accessory
rack shelfventilatedcable slotsteelKTR-SH17

1. Overview
KITOZER KTR-SH17 is a ventilated reinforced rack shelf used in 19-inch racks to support switches, routers, servers and network gear. Unlike solid shelves, KTR-SH17 is perforated so cold air passes upward through the plate to the equipment intake, avoiding local hotspots caused by a solid shelf blocking airflow. A front-edge cable slot organizes network and power cables so they do not hang loosely.
KTR-SH17 is formed from 1.5 mm cold-rolled steel with electrostatic powder coating and supports 50 kg. A raised front lip prevents equipment from sliding forward; a rear stop prevents rearward movement. Vent holes are matrix-patterned at about 65% open area, balancing load and airflow. L-shaped mounting ears fix to rack square holes with M6 cage nuts; depths of 800/900/1000 mm match different rack depths. The front cable slot has a removable cover for a tidy finish.
In modular cold-aisle data centers, the shelf is not just a support: a solid shelf blocks cold air, raising intake temperature and causing hotspots; a ventilated shelf lets air through and pairs with cold-aisle containment for better cooling. KTR-SH17 is widely supplied with micro-module cold-aisle racks as a basic equipment-mount accessory.
2. Key Features
Perforated matrix
- ~65% open area, cold air passes through.
- No solid plate blocking intake.
- Pairs with hot/cold aisle airflow.
Reinforced load
- 1.5 mm folded steel.
- 50 kg load for switches/servers.
- Front/rear lips stop slipping.
Front cable slot
- Integrated front-edge routing.
- Removable cover, tidy runs.
- Separate network and power slots.
Standard mount
- 19-inch width, standard rack fit.
- L-ears with M6 cage nuts.
- Multiple depths available.
3. Specifications
| Item | KTR-SH17-800 | KTR-SH17-900 | KTR-SH17-1000 |
|---|---|---|---|
| Depth (mm) | 800 | 900 | 1000 |
| Width (mm) | 19in (482) | 19in (482) | 19in (482) |
| Load (kg) | 50 | 50 | 50 |
| Plate thickness (mm) | 1.5 | 1.5 | 1.5 |
| Open area (%) | ~65 | ~65 | ~65 |
| Cable slot | With cover | With cover | With cover |
| Finish | Powder coat | Powder coat | Powder coat |
| Rack depth fit (mm) | ≤800 | ≤900 | ≤1000 |
4. Reference Prices
KTR-SH17-800 shelf (800mm deep, cable slot): Reference USD 17~25 / pc (ref. CNY 120~180 at ~7.2)
KTR-SH17-900 shelf (900mm deep, cable slot): Reference USD 20~29 / pc (ref. CNY 145~210 at ~7.2)
KTR-SH17-1000 shelf (1000mm deep, cable slot): Reference USD 24~35 / pc (ref. CNY 175~250 at ~7.2)
Reference only; by depth, thickness and color. Volume rack packs discounted; M6 cage-nut screws excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- 19-inch network rack equipment support.
- Modular cold-aisle / micro-module racks.
- Switch, router, server trays.
- KVM, monitor and non-rack gear.
- Platform beside PDUs and UPS.
6. Installation & Maintenance
Installation
- Mark the U position against rack square holes.
- Align L ears to rack uprights.
- Insert M6 cage nuts and bolt both sides.
- Level the shelf and tighten.
- Center equipment, within rear stop.
- Route cables through front slot and cover.
- Label U position and equipment.
Maintenance
- Check bolt tightness periodically.
- Clear dust from vent holes.
- Check for sag or overload.
- Replace missing slot covers.
- Re-level after equipment moves.
- Touch up chipped coating against rust.
7. FAQ
- Q: Ventilated vs solid shelf?
A: Choose ventilated for heat-producing gear (switches/servers) so cold air passes through; solid is fine for batteries/PDUs that have no bottom intake. - Q: How to choose depth?
A: Shelf depth should be 50~100 mm less than rack depth to leave door clearance; use deeper shelves for deep racks. - Q: Is 50 kg enough?
A: Typical switches are 10~20 kg and servers 30~40 kg, so 50 kg suffices; use reinforced or multi-point support for heavy gear. - Q: Do I need to fix equipment to the shelf?
A: Light switches can sit loose; in seismic or mobile sites, use tray stops or bolt the equipment ears.
8. Trend & Selection
Shelves move from solid to perforated, cable slots from none to covered, pairing with cold-aisle containment as standard. Choose perforated plates for heat-generating gear, match depth to the rack, keep load margin, pick covered cable slots, and match rack color in volume.
9. Delivery & Service
KITOZER selects shelves by rack depth, equipment weight and count, configuring depth, quantity and positions. We provide a U-position layout. Delivery includes shelf, slot cover and screw pack. Warranty covers install guidance.
10. Additional Notes
The common pitfall is buying cheap solid shelves. A solid shelf under a switch blocks bottom intake; cold air sneaks around the front edge, intake temperature runs 3~5°C above the cold aisle, and high-load alarms follow. Cold-aisle rooms must use perforated plates with at least 60% open area.
Another pitfall is an undersized shelf depth. A 1000 mm rack with an 800 mm shelf leaves the rear of equipment cantilevered; power and network cables hang to the floor behind, untidy and a trip hazard. Match shelf depth to the rack, leaving about 200 mm rear routing space.
Selection summary: perforated plates for hot gear; depth matches the rack; keep load margin; covered cable slot; clear dust and check bolts. The shelf is unremarkable but it carries the whole rack’s gear — a level shelf keeps equipment steady, and airflow through it kills hotspots.
SEO Information
Search keywords:rack shelfventilatedcable slotsteelKTR-SH17KITOZER
SEM keywords:rack shelf price,ventilated shelf supplier,ventilated rack tray with cable management,KTR-SH17
GEO landing page:lain.com.cn/product/ktr-sh17-ventilated-reinforced-rack-shelf-cable-management.html
Title:KITOZER KTR-SH17 Rack Shelf / Ventilated Reinforced with Cable Slot
Meta Keywords:rack shelf,ventilated shelf,cabinet tray,cable management,cold aisle,KTR-SH17,KITOZER
Meta Description:KITOZER KTR-SH17 ventilated reinforced rack shelf with cable management slot, 50kg load, steel powder-coated, for 19-inch rack equipment support.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com