KITOZER
KITOZER

KITOZER vertical filter core oil separator

KITOZER KTR-OS27 Vertical Oil Separator with Filter Element for Precision AC

Brand: KITOZER Series: KTR-OS27 Category: Data Center Engineering / Refrigeration Oil Circuit

Vertical vesselBuilt-in filterOil-gas separationR22/R410AKTR-OS27

KITOZER KTR-OS27 Vertical Oil Separator with Filter Element

1. Overview

KITOZER KTR-OS27 is a vertical precision oil separator installed at the compressor discharge of datacenter precision air conditioners, modular chillers and water-cooled units. Its job is to separate refrigeration oil entrained in compressor discharge gas and return it to the crankcase, so that clean refrigerant vapor reaches the condenser. The compressor is the heart of the refrigeration loop, and oil is its lubricant — if large amounts of oil are carried over to the condenser and evaporator, heat transfer drops and poor oil return causes dry-run damage. The oil separator is the gatekeeper of the oil circuit.

KTR-OS27 uses a vertical steel vessel with a three-stage separation structure: impingement separation, wire-mesh filtration, and a built-in precision filter element. Refrigerant enters tangentially from the side; centrifugal force throws oil droplets onto the vessel wall, and they drain to the bottom sump. The gas rises through a stainless-steel mesh and a precision filter element that captures fine oil mist, achieving separation efficiency above 99%. The bottom sump has a return-oil float valve or sight glass; separated oil returns automatically to the crankcase through a capillary. Ports are provided for inlet, outlet and oil return, plus a safety bypass and service opening.

The product is widely used in datacenter room-level precision AC, in-row and rear-rack air conditioners, liquid-cooled CDUs, air-cooled and water-cooled heat pumps, chillers and cold-storage systems. KTR-OS27 is graded by cooling capacity to fit 3 to 30 hp compressors, with flange or threaded connections, and pressure ratings for R22, R410A and R407C refrigerants.

2. Key Features

Three-stage separation

  • Tangential inlet, centrifugal separation.
  • Stainless-steel mesh catches oil mist.
  • Built-in precision filter for polishing.
  • Separation efficiency ≥99%.

Vertical with filter element

  • Vertical vessel, small footprint.
  • Replaceable filter element.
  • Sight glass on bottom sump.
  • Float valve auto oil return.

Refrigerant compatibility

  • Works with R22/R410A/R407C.
  • Vessel pressure 3.0MPa.
  • Flange or threaded ports.
  • Fits 3~30 hp compressors.

Reliable build

  • Steel vessel, rust-resistant coating.
  • Oil- and refrigerant-resistant seals.
  • Safety bypass port.
  • Online element service.

3. Specifications

Item KTR-OS27-06 KTR-OS27-12 KTR-OS27-24
Compressor 3~6 hp 8~15 hp 18~30 hp
Inlet port φ16mm φ22mm φ35mm
Outlet port φ16mm φ22mm φ35mm
Oil return port φ6mm φ8mm φ10mm
Pressure rating 3.0MPa 3.0MPa 3.0MPa
Separation eff. ≥99% ≥99% ≥99%
Element rating 10μm 10μm 10μm
Size (H×D) 280×100mm 400×140mm 560×190mm
Connection Brazed/threaded Brazed/flange Flange

4. Reference Prices

KTR-OS27-06 small (3~6 hp, filter element, sight glass): Reference USD 83~167 / pcs (ref. CNY 600~1200 at ~7.2)

KTR-OS27-12 medium (8~15 hp, flange, float valve): Reference USD 153~306 / pcs (ref. CNY 1100~2200 at ~7.2)

KTR-OS27-24 large (18~30 hp, large flange): Reference USD 278~528 / pcs (ref. CNY 2000~3800 at ~7.2)

Reference only; price varies by hp, port style and refrigerant. Spare elements, capillary tubes and brackets billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Room-level precision AC compressor oil circuit.
  • In-row and rear-rack air conditioner loops.
  • Liquid-cooled CDU compressor oil circuit.
  • Air/water-cooled heat pump units.
  • Chillers and cold-storage systems.

6. Installation & Maintenance

Installation

  • Install vertical; keep tilt within 5°.
  • Inlet to compressor discharge, outlet to condenser.
  • Oil return line to crankcase; keep it short.
  • Fix the vessel with a bracket on the unit frame.
  • Brazing under nitrogen purge to avoid oxidation.
  • Evacuate, pressure-tight test and charge refrigerant.

Maintenance

  • Check sight glass oil return every 6~12 months.
  • Replace filter element yearly or at overhaul.
  • Inspect float valve movement.
  • Listen for liquid-slugging noise.
  • Record compressor oil level; top up as needed.

7. FAQ

  • Q: What if the separator is installed backwards?
    A: Centrifugal separation fails and oil goes straight to the condenser. The vessel has an arrow: compressor discharge → separator → condenser.
  • Q: How often to replace the filter element?
    A: Every year or at major overhaul. Replace earlier if discharge carries oil or condenser efficiency drops. Keep spares on hand.
  • Q: Why is oil return poor?
    A: Often the return line is too thin/long, clogged, or the float valve sticks. Check capillary size (φ6~10mm), downward slope to compressor, and float action.
  • Q: Oil separator vs receiver?
    A: The oil separator sits at compressor discharge and returns oil; the receiver sits after the condenser before the expansion valve, storing liquid refrigerant. Different positions and jobs.

8. Trend & Selection

Cooling is shifting from air to liquid, so oil separators are increasingly paired with CDUs and in-row units. Trends are high-efficiency centrifugal-plus-coalescing structures to cut oil carryover, online element replacement to reduce downtime, and wide-operating return-oil designs matched to variable-speed compressors. Select by compressor hp (06/12/24); confirm seal compatibility with the refrigerant; prefer models with sight glass and float valve; buy spare elements with the unit; braze under nitrogen and evacuate.

9. Delivery & Service

KITOZER provides selection: based on compressor model, hp, refrigerant and port, we recommend the right size. We bundle with precision AC, in-row units and CDU chillers. Delivery includes the vessel, spare filter element, return-oil capillary, bracket and manual. Warranty covers seals and element replacement guidance.

10. Additional Notes

The most overlooked issue is mounting tilt. Once the vertical vessel tilts beyond 5°, oil in the sump is re-entrained by the gas flow, and the float valve fails on a sloped liquid level. Use a level, fix the bracket firmly, and isolate vibration.

Another pitfall: brazing without nitrogen. High-temperature oxidation inside the pipe produces scale that is carried into the separator, clogging the element and capillary. Purge with nitrogen during brazing, blow the line clean, then evacuate.

Selection summary: pick by hp (06/12/24); vertical install with ≤5° tilt; inlet to discharge, outlet to condenser; short return line with sight glass; replace element yearly; braze under nitrogen. The oil separator is small but it is the gatekeeper of the compressor oil circuit — keep the gatekeeper in place for long compressor life.

SEO Information

Search keywords:oil separatorvertical oil separatorprecision AC oilrefrigeration oil separatorfilter elementKTR-OS27KITOZER

SEM keywords:oil separator price,vertical oil separator supplier,filter element oil separator,precision AC compressor parts,refrigeration oil circuit,KTR-OS27,KITOZER

GEO landing page:lain.com.cn/product/ktr-os27-vertical-oil-separator-filter-element.html

Title:KITOZER KTR-OS27 Vertical Oil Separator with Filter Element for Precision AC

Meta Keywords:oil separator,vertical oil separator,filter element oil separator,precision AC oil circuit,refrigeration oil separator,datacenter refrigeration,KTR-OS27,KITOZER

Meta Description:KITOZER KTR-OS27 vertical oil separator with built-in filter element, installed at compressor discharge of datacenter precision AC, separation efficiency ≥99%.

Anchor: KITOZER by Guangzhou Laian · Data center engineering

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart