KITOZER
KITOZER

KITOZER vertical oil level sight separator

KITOZER KTR-OS29 Vertical Oil Separator with Sight Glass for Precision AC

Brand: KITOZER Series: KTR-OS29 Category: Data Center Engineering / Refrigeration Auxiliary

Oil separatorVertical sight glassOil returnKTR-OS29

KITOZER KTR-OS29 Vertical Oil Separator with Sight Glass

1. Overview

KITOZER KTR-OS29 is a vertical oil separator with a sight glass, installed between the compressor discharge line and the condenser in datacenter precision air-conditioning refrigeration systems. Its job is to separate lubricating oil entrained in the hot, high-pressure discharge gas and return it automatically to the compressor crankcase. In screw or scroll compressors of room-level precision units, a portion of refrigeration oil always leaves with the discharge. If this oil does not return promptly, the crankcase level drops, causing poor lubrication, bearing wear and eventual seizure. If oil enters the condenser and evaporator, it forms an oil film on the tubes, reducing heat transfer and cooling capacity.

KTR-OS29 uses a vertical shell with an internal baffle plus a mesh separation element. Oil droplets are removed by a combination of velocity change, direction reversal and centrifugal impingement. The lower section forms an oil reservoir; a return hole (with capillary or manual valve) connects to the suction line or crankcase. A transparent sight glass on the side lets technicians read the oil level while running. The shell is seamless steel or copper with anti-corrosion coating, and connections are solder or thread, compatible with R22, R410A, R407C and R134a.

Typical uses: datacenter precision AC, constant-temperature/humidity rooms, cold-storage compressors and industrial water chillers. One separator is fitted per compressor. During maintenance, the sight glass reveals: low level means poor return or undercharge; high level may indicate blocked return; foaming means refrigerant has dissolved in the oil (oil migration). These visual cues are vital for refrigeration-system health.

2. Key Features

Vertical high-efficiency separation

  • Vertical shell, gas flows upward.
  • Baffle plus mesh secondary separation.
  • Gravity settling of oil droplets.
  • Low discharge oil carry-over.

Sight glass

  • Transparent side glass.
  • Oil level visible while running.
  • Judges return and undercharge.
  • Reference level marks.

Reservoir and auto return

  • Lower reservoir collects oil.
  • Capillary returns oil to crankcase.
  • Manual valve for service.
  • Multiple refrigerants supported.

Pressure-rated

  • Seamless steel/copper shell.
  • Handles high discharge pressure.
  • Diamond-pierced welds.
  • Coating suits room environment.

3. Specifications

Item KTR-OS29 KTR-OS18
Type Vertical with sight glass Vertical, no glass
Mechanism Baffle + mesh composite Baffle only
Refrigerant R22/R410A/R407C/R134a R22/R410A
Connection Solder / thread Solder
Sight glass Yes (with scale) No
Return port Valve + capillary Fixed tube
Shell Seamless steel Copper
Compressor hp 3 to 15 hp 1 to 5 hp

4. Reference Prices

KTR-OS29 vertical oil separator (sight glass, 3-15 hp): Reference USD 49 to 125 / pc (ref. CNY 350 to 900 at ~7.2)

KTR-OS18 economy (no glass, 1-5 hp): Reference USD 21 to 56 / pc (ref. CNY 150 to 400 at ~7.2)

Reference only; varies by fitting, refrigerant and quantity. Capillary, valve and insulation billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Datacenter precision air conditioning.
  • Constant-temperature/humidity labs.
  • Cold storage and low-temp units.
  • Industrial water chillers.
  • Commercial central AC compressors.

6. Installation & Maintenance

Installation

  • Mount vertically near discharge line.
  • Observe inlet/outlet arrows; never reverse.
  • Connect bottom return to crankcase via capillary.
  • Nitrogen-purge during brazing.
  • Secure against pipe vibration.
  • Evacuate and leak-test before charging.

Maintenance

  • Read oil level through sight glass.
  • Top up matching oil if below mark.
  • Check return capillary for blockage.
  • Replace glass seal if frosting or leaking.
  • Inspect welds annually.
  • Record oil color; black means degradation.

7. FAQ

  • Q: No oil visible in the glass?
    A: Usually: system undercharged, blocked return capillary, oil flushed into the line during migration, or wrong mounting height. Top up to mid-glass, then inspect the return line.
  • Q: Can it be mounted horizontally?
    A: No. The vertical design relies on gravity. Horizontal mounting destroys the gas-oil separation path and oil enters the condenser. Keep it vertical.
  • Q: Why is the glass foaming?
    A: Oil migration: refrigerant has dissolved in the crankcase oil and flashes on startup. Common after long shutdown, without crankcase heater, or overcharge. Pre-heat the crankcase for hours before starting.
  • Q: What size separator per compressor?
    A: Match displacement and hp: 3-15 hp uses KTR-OS29, 1-5 hp uses KTR-OS18. The port should match the discharge pipe; too large lowers velocity, too small adds resistance.

8. Trend & Selection

Precision AC is moving toward high efficiency and variable-speed compressors. Separators evolve from simple baffles to composite centrifugal-plus-mesh designs; some units integrate oil-level sensors for remote DCIM monitoring. Inverter compressors have trouble returning oil at low speed, so efficient separators with oil-return cycle control are essential. Choose the vertical model with sight glass for easy service; match hp and refrigerant; nitrogen-purge when brazing; fit a valve on the return capillary; mount close to the compressor; clean the glass regularly.

9. Delivery & Service

KITOZER supplies refrigeration auxiliary packages: based on compressor brand, hp and refrigerant, we recommend the separator model and fittings. Bundled with precision AC, condenser, expansion valve and drier. Delivery includes separator, capillary, valve and manual; bulk projects include brazing guidance and evacuation support. Warranty covers shell weld defects.

10. Additional Notes

The most overlooked fault is a blocked return capillary. The capillary is only 2-3 mm inside; poor system cleanliness lets flux, oxide or drier debris block it, so oil goes in but not out, and the compressor runs dry. Blow the lines with nitrogen before brazing, use a quality drier, and change oil after initial run-in.

Another pitfall: brazing without nitrogen. Hot steel in air forms oxide scale that sheds into the refrigerant, blocking capillaries and damaging the compressor. Purge with low-pressure nitrogen during braze.

Selection summary: vertical with sight glass; 3-15 hp = KTR-OS29; match R22/R410A; nitrogen-purge braze; valved capillary return; vertical mount near compressor. The separator is the compressor’s oil keeper; that little oil in the glass directly determines compressor longevity.

SEO Information

Search keywords:oil separatorvertical oil separatorrefrigeration oil separatorsight glass oil separatorprecision AC oil separatorcompressor oil returnKTR-OS29KITOZER

SEM keywords:[‘oil separator price,vertical oil separator supplier,refrigeration oil separator,sight glass oil separator,precision AC oil separator,KTR-OS29,KITOZER’]

GEO landing page:lain.com.cn/product/ktr-os29-vertical-oil-separator-sight-glass.html

Title:KITOZER KTR-OS29 Vertical Oil Separator with Sight Glass for Precision AC

Meta Keywords:oil separator,vertical oil separator,refrigeration oil separator,sight glass oil separator,precision AC oil separator,compressor oil return,KTR-OS29,KITOZER

Meta Description:KITOZER KTR-OS29 vertical oil separator with sight glass, separates oil from compressor discharge, returns oil to crankcase, for datacenter precision AC.

Anchor: KITOZER · Data center engineering

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart