ToggleProduct Overview
The KITOZER vertical PDU cabinet is a zero-U power distribution unit mounted vertically inside a server rack, delivering 32 A of continuous power to 12 IEC C13 and 4 IEC C19 outlets across the rack height. Built-in metering measures voltage, current, power factor, and energy consumption at the input branch, and the PDU reports data over Modbus TCP or SNMP to the DCIM platform. Switchable outlet groups allow remote reboot of hung servers without sending staff to the rack. The rugged steel housing and screw-secured outlets support heavy cord pulls in dense data hall environments. The zero-U form factor leaves all rack space available for IT equipment, and the dual network port supports daisy-chain monitoring.
Technical Specifications
Rated input 32 A, 230 V single phase, input cable 3 m H07RN-F 6 mm2 with IEC60309 32 A plug. Outlets: 12 x IEC C13 and 4 x IEC C19, grouped into 4 switchable branches. Branch protection: 4 x 16 A single-pole breakers. Metering: voltage, current per branch, active power, energy, power factor. Communication: 10/100 Ethernet, Modbus TCP, SNMP v3, Web HMI. Mounting: zero-U vertical, fits 600 mm and 800 mm wide racks. Operating temperature 0 to 45 degrees Celsius. CE, RoHS, IEC 60950. Warranty 3 years. Shipping weight 4 kg.
Application Scenarios
This vertical PDU is used in enterprise data centers, colocation cages, and server rooms where per-rack power visibility and remote reboot are required. It is the standard choice for high-density server racks hosting virtualization hosts, storage nodes, and GPU compute servers. The switchable outlet groups let operators cycle a single hung server without interrupting neighbors. The metering data supports chargeback and capacity planning. It is also used in retail server closets, university computer rooms, and hospital IT departments where remote power management reduces on-site staff time. The PDU can be deployed in new racks or retrofitted into existing racks as a power monitoring upgrade. The switched outlets allow scheduled power cycling during maintenance windows.
Key Advantages
Zero-U mounting leaves all rack space available for IT equipment. Per-branch metering eliminates the need for separate power meters. Remote outlet switching reduces truck rolls and improves uptime. The sturdy steel housing resists cord pull-out. The dual network port supports daisy-chain monitoring. The Web HMI provides instant access without additional software. The PDU is compatible with third-party DCIM platforms through standard Modbus TCP and SNMP, avoiding vendor lock-in. The per-outlet switching supports remote reboot of hung servers, which is especially valuable in unmanned edge sites. The energy metering data supports chargeback to different departments or tenants.
Installation and Maintenance Recommendations
Mount the PDU in the vertical cable duct on the rear of the rack using the included brackets. Connect the input to a dedicated 32 A branch in the room PDU. Do not exceed 80 percent of rated current for continuous operation. Label every outlet with the name of the connected server. Firmware updates should be performed during a maintenance window. Periodically inspect outlets for discoloration caused by loose plugs. Keep the network management port on a dedicated management VLAN for security. The PDU ships with a mounting bracket kit, a network cable, and a quick-start guide. The PDU can be mounted on either side of the rack, and the input cord length can be customized for deep cabinets. The factory provides a MIB file for SNMP integration and a REST API documentation for custom monitoring. The PDU is available in C13-only, C19-only, or mixed outlet configurations to match different server power cords. Three-phase 63 A and 125 A versions are also available for high-density GPU racks. The PDU carries a 3-year warranty, and replacement outlet modules are stocked as service parts. The PDU is available in black or gray finish to match the rack. An environmental sensor kit with temperature, humidity, and water leak probes is available as an add-on for remote monitoring.
Price
From $420/pc. Contact +86 13922289957 for three-phase 63 A variants, outlet customization, and DCIM integration.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com