The KITOZER vertical PDU cabinet is a zero-U power distribution unit mounted vertically inside a server rack, delivering 32 A of continuous power to 12 IEC C13 and 4 IEC C19 outlets across the rack height. Built-in metering measures voltage, current, power factor, and energy consumption at the input branch, and the PDU reports data over Modbus TCP or SNMP to the DCIM platform. Switchable outlet groups allow remote reboot of hung servers without sending staff to the rack. The rugged steel housing and screw-secured outlets support heavy cord pulls in dense data hall environments.
Technical Specifications
Rated input 32 A, 230 V single phase, input cable 3 m H07RN-F 6 mm2 with IEC60309 32 A plug. Outlets: 12 x IEC C13 and 4 x IEC C19, grouped into 4 switchable branches. Branch protection: 4 x 16 A single-pole breakers. Metering: voltage, current per branch, active power, energy, power factor. Communication: 10/100 Ethernet, Modbus TCP, SNMP v3, Web HMI. Mounting: zero-U vertical, fits 600 mm and 800 mm wide racks. Operating temperature 0 to 45 degrees Celsius. CE, RoHS, IEC 60950. Warranty 3 years.
Application Scenarios
This vertical PDU is used in enterprise data centers, colocation cages, and server rooms where per-rack power visibility and remote reboot are required. It is the standard choice for high-density server racks hosting virtualization hosts, storage nodes, and GPU compute servers. The switchable outlet groups let operators cycle a single hung server without interrupting neighbors. The metering data supports chargeback and capacity planning.
Key Advantages
Zero-U mounting leaves all rack space available for IT equipment. Per-branch metering eliminates the need for separate power meters. Remote outlet switching reduces truck rolls and improves uptime. The sturdy steel housing resists cord pull-out. The dual network port supports daisy-chain monitoring. The Web HMI provides instant access without additional software.
Installation and Maintenance Recommendations
Mount the PDU in the vertical cable duct on the rear of the rack using the included brackets. Connect the input to a dedicated 32 A branch in the room PDU. Do not exceed 80 percent of rated current for continuous operation. Label every outlet with the name of the connected server. Firmware updates should be performed during a maintenance window. Periodically inspect outlets for discoloration caused by loose plugs. Keep the network management port on a dedicated management VLAN for security.