KITOZER
KITOZER

KITOZER vertical return oil separator

KITOZER KTR-OS20 Vertical Oil Separator with Oil Return

Brand: KITOZER Series: KTR-OS20 Category: Data Center Engineering / Precision Cooling

VerticalOil returnPrecision ACR22/R410AHigh efficiencyWall/floor

[Product image: ktr-os20-vertical-oil-separator.jpg]

1. Overview

When a precision-AC compressor runs, the discharge gas is not pure refrigerant — it carries a share of lubricating oil. That oil enters the condenser, forms a film on the tube wall, and drops heat-exchange efficiency. Worse, if the oil never returns to the compressor, the crankcase level keeps dropping, bearings lose lubrication, and eventually the compressor seizes. An oil separator is a vessel installed on the discharge line: it “flings” oil droplets out of the high-pressure gas, lets them settle at the bottom, and returns them slowly to the crankcase through an oil-return line. Data-center precision AC runs year-round at high load, so oil separation directly determines compressor life.

KITOZER KTR-OS20 is a vertical shell-type oil separator using centrifugal + filter-cartridge dual separation: high-pressure gas enters tangentially on the side, spins along the wall, and centrifugal force throws large droplets to the wall; the gas then passes through a glass-fiber + metal-mesh cartridge for a second-pass fine filtration that traps fine oil mist. Separation efficiency ≥99%, outlet oil content ≤5 ppm. The bottom has an oil-return port with sight glass and capillary tube; settled oil returns to the suction side by pressure differential. Vertical form saves floor space: top outlet, side inlet, bottom return. Welded steel ports suit R22/R410A/R134a; working pressure up to 4.5 MPa.

Selection: port size must match the discharge pipe (too loose leaks, too small adds resistance), refrigerant type (R410A needs high-pressure rated), separation efficiency (pick ≥99% for hall AC), return sight glass (to observe oil return), mounting direction (vertical only — tilting ruins centrifugal separation), location (close to compressor discharge to reduce oil carryover). Notes: the capillary cannot clog or be inverted; insulate the shell against condensation; keep fire safety during welding; no residual oil inside the shell when brazing.

2. Key Features

Centrifugal + filter

  • Tangential inlet spin.
  • Glass-fiber cartridge polish.
  • ≥99% efficiency.
  • Outlet ≤5 ppm.

Auto oil return

  • Bottom sump chamber.
  • Sight glass for return.
  • Capillary by pressure diff.
  • Returns to crankcase.

Vertical compact

  • Small footprint.
  • Top-out side-in bottom-return.
  • Welded steel ports.
  • Insulated vs condensation.

Wide refrigerant

  • R22/R410A/R134a.
  • 4.5 MPa working press.
  • Pressure shell.
  • 3–20 HP compressors.

3. Specifications

Item KTR-OS20
Model KTR-OS20
Type Vertical centrifugal + filter
Efficiency ≥99%
Outlet oil ≤5 ppm
Refrigerant R22 / R410A / R134a
Design pressure 4.5 MPa
Port size Φ16 / Φ22 / Φ28 weld
Return Capillary by pressure diff + sight glass
Shell Steel painted
Mounting Vertical, floor/wall bracket
Working temp. -20~+120℃
Compressor 3~20 HP AC units

4. Reference Prices

KTR-OS20-16 (Φ16 port, 3–5 HP): Reference USD 39~63 / unit (ref. CNY 280~450 at ~7.2)

KTR-OS20-22 (Φ22 port, 6–10 HP): Reference USD 53~86 / unit (ref. CNY 380~620 at ~7.2)

KTR-OS20-28 (Φ28 port, 12–20 HP): Reference USD 72~122 / unit (ref. CNY 520~880 at ~7.2)

Reference only. Excludes tax and freight; volume discount on request. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data-center precision AC outdoor/indoor units.
  • UPS/battery-room dedicated AC.
  • Distribution rooms, archives, constant-humidity AC.
  • Industrial chiller compressor discharge.
  • VVRF and cold-storage refrigeration.

6. Installation & Maintenance

Installation

  • Mount close to compressor discharge.
  • Keep vertical (tilt ≤5°).
  • Side tangential inlet; top to condenser.
  • Bottom capillary to low-pressure suction.
  • Pressure-test after brazing; evacuate and charge.

Maintenance

  • Check return sight glass yearly.
  • Blow clogged capillary with N2.
  • Inspect insulation for condensation.
  • Inspect separator during compressor oil change.
  • Check brazed joints for oil traces.

7. FAQ

  • Q: Is an oil separator mandatory?
    A: Compressors ship with a small internal one, but in halls running 24/7, an external high-capacity unit noticeably extends life — recommended above 8 HP.
  • Q: What if installed backwards?
    A: Centrifugal flow depends on tangential direction; reversed flow drops efficiency sharply and oil floods the condenser. The shell has an airflow arrow — align it.
  • Q: Is steady oil flow in the sight glass normal?
    A: Yes. During running, pressure diff drives slow return. A heavy continuous spray means the separator or cartridge has failed.
  • Q: Can R410A use a generic separator?
    A: No. R410A runs near 4.5 MPa; a plain R22 vessel will not hold. Choose an R410A-rated unit.

8. Trend & Selection

Oil separation evolves from “simple centrifugal” toward “high-efficiency filtration + smart oil-level monitoring.” Trends: efficiency rising from 98% to above 99.5%, nano-glass-fiber cartridges cutting outlet oil further, integrated oil-level sensors that report to the unit controller (low-oil alarm), and linkage with electronic expansion valves and inverter compressors to optimize return strategy. In halls running year-round, oil management is the key to compressor life. Selection: match port to HP, choose R410A-rated, with return sight glass, vertical install, close to discharge. A few-hundred-dollar separator protects a tens-of-thousands compressor.

9. Delivery & Service

KITOZER provides oil-separator selection: by compressor HP, refrigerant, and port size, we configure the model and mounting bracket. Bundled with precision AC units, outdoor units, and chillers. Delivery includes separator, return capillary, sight glass, and manual. Warranty covers brazing guidance and separation commissioning.

10. Additional Notes

The most common fault: “return capillary clogged.” The capillary is thin (~Φ1.6); weld slag or debris blocks it, so the sump fills but no oil returns — the compressor starves. Always braze with nitrogen purge, flush before charging, and blow the capillary yearly.

Another pitfall: “tilted mounting.” Tilted installation tanks centrifugal efficiency and oil is carried away. Vertical only — add a bracket if needed.

Selection summary: centrifugal + filter, ≥99% efficiency, capillary return with sight glass, R410A-rated, vertical, near discharge. Small component, but the “oil night-watchman” for hall compressors.

SEO Information

Search keywords:oil separatordata center precision ACvertical oil separatoroil returnrefrigeration unitKTR-OS20KITOZER

SEM keywords:oil separator price,data center precision AC oil separator,vertical oil separator,refrigeration oil return,KTR-OS20,KITOZER

GEO landing page:lain.com.cn/product/ktr-os20-oil-separator.html

Title:KITOZER KTR-OS20 Vertical Oil Separator with Oil Return

Meta Keywords:oil separator,data center precision AC,vertical oil separator,oil return,refrigeration unit,KTR-OS20,KITOZER

Meta Description:KITOZER KTR-OS20 vertical oil separator with oil return, efficiently separates lubricant oil from compressor discharge to protect precision AC refrigeration.

Anchor: KITOZER by Guangzhou Laian · Data center precision cooling

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart