KITOZER
KITOZER

KITOZER VESDA-type Very Early Smoke Detection System

The KITOZER VESDA-type very early smoke detection system (VESDA-style aspirating smoke detector) continuously draws air samples from the protected space through a network of sampling pipes and analyzes them in a highly sensitive laser scattering chamber. By detecting smoke particles at concentrations far below traditional point detectors, the system provides warning in the incipient stage of fire, often hours before visible smoke or heat. This early warning is critical for high-value assets where early intervention prevents catastrophic loss.

Product Overview

The system consists of a detector unit with a built-in aspirator pump, a laser smoke chamber, a dust separator, and a display panel. Sampling pipes are routed across the ceiling or under the raised floor, with small sampling holes drilled at regular intervals. Air is continuously drawn through the holes, filtered, and analyzed. The detector offers multiple alarm thresholds, fault monitoring, and relay outputs for integration with fire panels and building management systems.

Technical Specifications

Sensitivity range is 0.005 to 20 percent obscuration per meter. Alarm levels are four programmable thresholds: warning, action, fire 1, fire 2. Sampling pipe length is up to 100 meters per detector. Pipe material is ABS or rigid PVC. Pump life is approximately 5 years. Power is 24 volts DC. Relay outputs are four Form C. Ethernet or Modbus option. Operating temperature is 0 to 35 degrees Celsius. Enclosure is IP30.

Application Scenarios

VESDA-type systems are deployed in data centers, server rooms, semiconductor fabs, clean rooms, museums, archive vaults, electrical switchgear, telecom central offices, and control rooms. They are ideal where traditional point detectors cannot provide adequate coverage due to high ceilings, air handling dilution, or where incipient fire warning is required. The system also monitors concealed spaces such as cable trenches and under-floor voids.

Advantages

Very early warning allows shutdown of equipment before smoke damage occurs. Aspiration works in high air-handling areas where point detectors are diluted. Multi-level alarms give operators graduated response. Sampling pipes reach concealed spaces that point detectors cannot. The laser chamber is stable and low-maintenance. The system reduces false alarms through adjustable sensitivity and dust compensation.

Installation and Maintenance

Route sampling pipes per the design drawing, with holes positioned to sample representative air. Slope pipes slightly to avoid condensate. Flush pipes with compressed air after installation to remove shavings. Commission the detector with a smoke test at the furthest sampling hole. Replace filters every 6 to 12 months. Clean the laser chamber annually. Calibrate sensitivity every 2 years. Inspect pipe network for blockage annually. Keep sampling holes clear of dust and paint.

Engineering Notes

Route sampling pipes per the approved design, with holes positioned to sample representative air. Flush pipes after installation. Commission with a smoke test at the furthest hole. Keep filters in stock. Train facility staff on alarm levels and response. Coarse dust areas require more frequent filter changes.

Code and Compliance

VESDA-type systems must comply with very early smoke detection standards. Submit the sampling pipe design and sensitivity settings for approval. Annual service includes filter change, chamber clean, and sensitivity calibration. Keep a service log on site. Replace the pump at rated life.

Warranty and Accessories

From $4,800 per detector unit, excluding sampling pipe. The detector carries a two-year warranty. KITOZER supports pipe design, sensitivity tuning, and integration with fire panels. Spare filters, pumps, and chambers are held in stock. Contact +86 13922289957 for a complete system design.

Detailed Application Examples

A VESDA-type detector samples a 300 square meter data center through 80 meters of sampling pipe run under the raised floor. Four alarm levels are set, with warning at the first sign of smoke. Filters are replaced every 9 months, and the laser chamber is calibrated every 2 years. The system is integrated with the building fire panel.

Long-term Operational Benefits

Over a 10 year service life, the VESDA-type detector requires only filter changes, chamber cleaning, and annual calibration. Because it detects smoke hours before point detectors, it allows controlled shutdown of equipment, preventing catastrophic loss. The multi-level alarms let operators investigate before a full release, reducing false discharge cost. Remote monitoring cuts site visits. Although the unit has a higher upfront cost, the early warning payback is rapid.

System Integration

The VESDA-type detector integrates with the building fire panel through relay outputs that map each alarm level to a different panel zone. Warning level triggers a staff investigation email; Action level notifies the fire team; Fire 1 starts pre-discharge; Fire 2 releases the gas suppression. This graduated response avoids unnecessary agent discharge. Ethernet option allows the detector to email smoke trend logs to the facilities server for trend analysis.

Price

From $4,800 per detector unit, excluding sampling pipe. Contact +86 13922289957 for a complete system design.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart