KITOZER
KITOZER

KITOZER VRLA Battery: 12V 200Ah AGM For Long Runtime UPS

KITOZER 12V 200Ah VRLA AGM battery is a high-capacity sealed lead-acid battery designed for long-runtime UPS installations, telecom central offices, and large solar storage systems. Using Absorbent Glass Mat technology, the battery is maintenance-free and spill-proof, with a pressure relief valve that protects against overcharge abuse. Heavy-duty lead-calcium grids provide float service life up to 8 years in temperature-controlled environments.

Product Overview

The 12V 200Ah battery delivers 2400 watt-hours of nominal energy at the 20-hour rate. The rugged ABS container and copper-alloy terminals support high discharge currents required by large UPS systems. Front terminals simplify dense rack and cabinet installations. Each cell is individually vented, and the battery ships with a matched discharge report for string consistency.

The high capacity reduces the number of parallel strings required for a given runtime. Copper alloy terminals provide high conductivity.

The battery is designed for 8 year float service life. The front terminal design allows dense packing in battery cabinets.

The high capacity reduces the number of parallel strings required for a given runtime, lowering installation cost and improving reliability. Copper alloy terminals provide high conductivity and resist corrosion. The battery is suitable for both float and cyclic applications.

Technical Specifications

Nominal voltage 12V (6 cells). Rated capacity 200Ah at 20-hour rate to 1.75V/cell at 25C. Internal resistance less than 3.5mOhm. Operating temperature -15C to 50C, recommended 20-25C. Float charge voltage 13.5-13.8V at 25C, equalize 14.4-14.7V. Max charge current 50A. Discharge cut-off 10.5-11.0V. Self-discharge less than 3 percent per month. Dimensions 522 x 240 x 216mm, weight 62kg. CE, UL, ISO. KITOZER, 3 year warranty.

The battery ships factory-charged and ready for installation. Storage temperature should be between 0 and 30C.

The battery is designed for 20-hour rate discharge. The internal resistance is low for high discharge current.

Application Scenarios

This battery is specified for large UPS systems from 20kVA to 200kVA, telecom central office backup, solar off-grid storage, and emergency power systems. The high capacity reduces the number of parallel strings required for a given runtime, lowering installation cost and improving reliability. It is also used in industrial process control, hospital backup, and data center battery rooms.

In hospital backup systems, the battery protects medical equipment. The high capacity provides long runtime.

In telecom central offices, the battery provides standby power for communication equipment. The high capacity reduces parallel string count.

In emergency lighting systems, the battery provides reliable backup. The AGM design is maintenance-free.

In industrial process control, the battery provides standby power for PLC controllers. The high capacity provides long runtime.

In data center battery rooms, multiple 12V 200Ah batteries are configured in series strings to match the UPS DC bus voltage. Parallel strings achieve the required runtime. The battery is also used in off-grid solar systems for medium loads.

Advantages and Features

High capacity reduces parallel string count. AGM sealed maintenance-free design. Lead-calcium grids extend float life. Front terminals simplify dense installation. Low internal resistance supports high discharge current. Factory-matched strings improve consistency.

The battery is UN38.3 certified. Each battery ships with a discharge report.

The battery is CE and UL certified. The front terminal design simplifies installation.

The battery is CE, UL, and ISO certified. The 3 year warranty provides peace of mind.

Installation and Maintenance Advice

Install in a clean, ventilated battery room at 20-25C. Use insulated tools and wear safety gear. Tighten terminal bolts to recommended torque. Connect in series matching UPS DC bus. Use battery racks rated for 62kg per cell. Perform annual capacity tests. Equalize charge every 6 months for cyclic applications.

Keep the battery room well-ventilated. Store spare batteries in a cool, dry location.

Do not mix batteries of different ages. Keep the battery room well-ventilated.

Tighten terminal bolts to the recommended torque. Keep battery terminals clean and coated with anti-corrosion grease.

Perform annual capacity tests. Replace batteries that fall below 80 percent of rated capacity.

Do not mix batteries of different ages or manufacturers in the same string. Keep the battery room well-ventilated. Store spare batteries in a cool, dry location and recharge every 6 months.

Price

From $238/pc. Contact +86 13922289957 for 12V 200Ah battery pricing, matched string configuration, and battery rack supply.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top