1. Overview

The KITOZER KTR-FB12SC is a wall-mount 12-port SC UPC fiber termination box (ODC) for fiber splicing and termination in telecom rooms, floor wire closets and racks. The folded-steel box is powder-coated and wall- or rack-mountable; the front panel holds 12 SC UPC adapters (LC/FC options), and inside are stacked splice trays (up to 2 layers) for 12 splices and pigtail routing. The cable enters through the bottom gland, the strength member is anchored, each fiber is spliced to an SC pigtail, splices are protected with heat-shrink sleeves, slack is coiled in the tray, and SC heads plug into the front adapters—completing the run from outdoor cable to equipment patching.

The termination box is the link’s endpoint, turning bare backbone fiber into pluggable SC ports. KTR-FB12SC holds 12 cores (12 SC simplex or 6 SC duplex); with adapters the front face is 12 SC ports and the back takes the cable. The box includes a cable clamp, splice trays and routing rings, with a lockable door. It mounts on the wall of a wire closet or in a 19-inch rack via ears. Versus an open ODF rack, the wall box seals dust out for floor closets; versus a small terminal box, it holds more with a neat adapter panel. Keep bend radius over 30mm inside; splice loss ≤0.05dB.

Typical deploy: an office building puts one KTR-FB12SC in each floor wire closet; the vertical backbone arrives from the main room, splices to 12 SC ports, and room outlets run indoor fiber to the box, patched to switch optics with SC-SC cords. Datacenters use small wall boxes for row-head termination. Size by fiber count (12/24/48 ports), choose SC/LC interface and UPC (blue) polish, wall or rack mount, and single-mode 9/125 vs multimode 50/125. Match adapters and pigtails to core count and choose tray layers for slack.

2. Key Features

12-core termination

  • 12-port SC UPC panel.
  • Stacked trays.
  • Pigtails + adapters.
  • SM 9/125.

Steel enclosure

  • Powder-coated steel.
  • Wall/rack.
  • Lockable dust cover.
  • Cable clamp.

Low-loss splice

  • Splice loss ≤0.05dB.
  • Heat-shrink protection.
  • Slack coiled.
  • Bend ≥30mm.

Flexible config

  • SC/LC/FC option.
  • UPC/APC option.
  • 12/24/48 ports.
  • SM/MM.

3. Specifications

项目 KTR-FB12SC(12口SC壁挂) KTR-FB24SC(24口SC) KTR-FB24LC(24口LC)
端口数 12口SC 24口SC 24口LC
端面 UPC蓝色 UPC/APC UPC蓝色
模式 单模9/125 单模9/125 单模/多模
熔接盘 1至2层 2至3层 3层
安装 壁挂/机架 壁挂/机架 机架为主
箱体 冷轧钢喷塑 冷轧钢喷塑 冷轧钢喷塑
进缆方式 底部进缆 底部进缆 底部/侧进缆
熔接损耗 ≤0.05dB ≤0.05dB ≤0.05dB

4. Reference Prices

KTR-FB12SC 12-port SC UPC wall box (adapters+pigtails included):Reference USD 21 to 63 / unit (ref. CNY 150 to 450 at ~7.2)

KTR-FB24SC 24-port SC wall/rack box:Reference USD 35 to 97 / unit (ref. CNY 250 to 700 at ~7.2)

KTR-FB24LC 24-port LC high-density box:Reference USD 39 to 111 / unit (ref. CNY 280 to 800 at ~7.2)

Tray / adapter / pigtail accessories:Reference USD 0.7 to 4.2 / core (ref. CNY 5 to 30 at ~7.2)

Reference only; varies by port count, interface, polish and whether pigtails/adapters included. Splicing labor and cable material billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Floor closet termination.
  • Datacenter row-head patching.
  • In-rack terminal box.
  • Outdoor-to-indoor cable splice.
  • FTTO fiber to room.

6. Installation & Maintenance

Installation

  • Wall or rack-mount the box.
  • Feed cable through bottom gland.
  • Strip and anchor strength member.
  • Splice each core to a pigtail; heat-shrink.
  • Coil slack in tray, bend ≥30mm.
  • Plug SC heads into front adapters.

Maintenance

  • Keep door locked and dust out.
  • Cap unused ports.
  • Align cord plugs.
  • Check splices periodically.
  • Clean faces with a pen.
  • Label core numbers.

7. FAQ

  • Q: Is 12-port SC 12 cores or 6?
    A: SC simplex is one core per port—12 ports = 12 cores. With SC duplex adapters, 6 duplex ports also = 12 cores (paired TX/RX). State simplex or duplex when ordering.
  • Q: Wall box or ODF rack?
    A: Floor closets and small counts choose wall boxes (sealed, dust-proof); datacenter backbones and high density choose 19-inch ODF racks. In-rack row heads use small wall boxes.
  • Q: High splice loss?
    A: Clean the splicer and faces first and re-splice; if still high, check cleave length and angle—the cleave must be flat and perpendicular. Don’t sharply bend fiber in the tray; keep radius adequate.
  • Q: UPC or APC pigtail?
    A: Data networks usually use UPC (blue); video/broadcast and demanding analog links use APC (green). Keep a link’s polish consistent—don’t mix UPC and APC splices.

8. Trend & Selection

Fiber patching moves to high-density LC and pre-terminated MPO, but floor and rack endpoints still use SC/LC termination boxes. Size for core count plus 20% spare; keep polish UPC; use yellow SM pigtails; coil slack with adequate bend radius; match adapters to pigtails; label core numbers. The box is the cable’s closure—neat termination and clear labels make later service easy.

9. Delivery & Service

KITOZER supplies fiber patching packages: by core count and route we recommend wall-box/ODF capacity, interface and polish, with pigtails, adapters and trays. Delivery includes box, adapters, pigtails and mounts; bulk projects include splicing and link testing. Deformed boxes or poor adapter contact under warranty are replaced free.

10. Additional Notes

The common mistake is coiling slack into a tight kink. A bend radius under 30mm adds macrobend loss or breaks the fiber. Coil slack loosely and round through routing rings—no knots, and don’t trap it under the lid.

Another pitfall is not anchoring the strength member. Then the whole cable pull lands on the splice joints, which eventually pull apart. Anchor the strength member to the clamp so splices are strain-free.

Selection summary: 12-port SC UPC wall box, stacked trays, SM 9/125, bend ≥30mm, anchored strength member, consistent UPC polish. The box turns backbone cable into usable ports—the closure node of the cabling link.

SEO Information

Search keywords:fiber termination boxwall mount fiber box12 port SC boxfiber enclosureODF boxKTR-FB12SCKITOZER

SEM keywords:[fiber termination box price,wall mount fiber enclosure,12 port SC box,ODF box,KTR-FB12SC,KITOZER]

GEO landing page:lain.com.cn/product/ktr-fb12sc-wall-mount-12sc-fiber-box.html

Title:KITOZER KTR-FB12SC Wall-mount 12-port SC UPC Fiber Box

Meta Keywords:fiber termination box,wall mount fiber box,12 port SC box,fiber enclosure,ODF box,KTR-FB12SC,KITOZER

Meta Description:KITOZER KTR-FB12SC wall-mount 12-port SC UPC fiber box, steel, with adapters and pigtails, for floor and room fiber termination.

Anchor: KITOZER · Data Center Engineering

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart