KITOZER wall mount rack air conditioner 2kW

KITOZER KTR-RA Rack-Mounted / Wall-Mounted Cabinet Air Conditioner

Brand: KITOZER Series: KTR-RA Category: Data Center Engineering / Local Cooling

rack air conditionerwall-mounted rack ACcabinet coolerside mountdigital controllerRS485 alarm

1. Overview

The KITOZER KTR-RA series is a dedicated cabinet air conditioner for localized cooling of a single rack or a small rack group — distinct from whole-room outdoor AC (see article 08). Whole-room cooling (CRAH / precision AC) serves the entire room, while KTR-RA is a small air conditioner mounted directly on the rack itself: it draws hot air out of the cabinet, cools it, and returns cold air inside, forming a closed-loop cooling circuit that does not depend on room ambient. This rack-level cooling fits three cases: outdoor telecom cabinets, base-station cabinets and outdoor power cabinets where equipment generates heat but no room AC exists; individual high-density racks in a data center where room cooling is insufficient; and wall-mounted industrial control cabinets with PLC and VFD heat needing independent temperature control.

KTR-RA is sized by cooling capacity: 1 kW, 2 kW, 3 kW and 5 kW, powered by 220 V AC, with air-cooled (self-contained condenser) or water-cooled (external water circuit) options. The unit is a sealed box split into an indoor side (rack return/supply) and an outdoor side (exhaust to ambient). The indoor evaporator cools rack air; the outdoor condenser rejects heat to the environment. The unit is fixed to the rack wall on the side or top; supply and return openings are inside the rack, so indoor and outdoor air do not mix — the rack stays sealed, dust- and moisture-proof. The controller is a digital LCD with a setpoint, automatic compressor start/stop, and high/low pressure, fan-failure and filter-differential alarms.

Key metrics are cooling capacity, static pressure, temperature accuracy and mounting. Cooling capacity must exceed total rack heat with 30% headroom; static pressure must overcome internal duct resistance; ±2~3℃ accuracy is enough (not the ±0.5℃ required of precision room AC). Mounting options are side-mounted (unit hangs on the rack wall), top-mounted (unit sits on the rack top) or embedded (built into the door); outdoor cabinets usually use side or top. KTR-RA ships with RS485/Modbus to upload temperature, compressor state and alarms to the environment monitoring system.

2. Key Features

Rack-level closed loop

  • Mounts on the rack; closed-loop air circulation inside.
  • Independent of room ambient; runs in outdoor cabinets.
  • Rack stays sealed, dust- and moisture-proof.

Multiple capacities

  • 1/2/3/5 kW for small-to-mid racks.
  • Air-cooled standard; water-cooled option.
  • 220 V supply, easy site wiring.

Digital control & alarms

  • LCD thermostat; auto start/stop on setpoint.
  • High/low pressure, fan, filter, high-temp alarms.
  • RS485/Modbus to environment monitoring.

Flexible mounting

  • Side / top / embedded options.
  • Corrosion-resistant outdoor coating.
  • Washable intake filter.

3. Specifications

Item KTR-RA-1000 KTR-RA-2000 KTR-RA-3000
Cooling capacity 1000 W 2000 W 3000 W
Power supply 220V/50Hz 220V/50Hz 220V/50Hz
Power input ≤450 W ≤850 W ≤1300 W
Condensing air-cooled air-cooled air/water
Temp range 20~45℃ adj. 20~45℃ adj. 20~45℃ adj.
Temp accuracy ±2℃ ±2℃ ±2℃
Airflow 300 m³/h 500 m³/h 800 m³/h
Mounting side/top side/top side/top/embed
Communication RS485 Modbus RS485 Modbus RS485 Modbus
Ambient -20~55℃ -20~55℃ -20~55℃

4. Reference Prices

KTR-RA-1000/2000 rack AC (controller, filter, RS485): Reference USD 700~2,100 / unit (ref. CNY 5,000~15,000 at ~7.2)

KTR-RA-3000/5000 high-capacity rack AC (water-cooled, outdoor anti-corrosion): Reference USD 2,100~5,600 / unit (ref. CNY 15,000~40,000 at ~7.2)

Reference only; final quote depends on capacity, condensing type, mounting, and outdoor anti-corrosion. Bulk negotiable. Brackets, drain pipe and power billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Outdoor telecom, base-station and power cabinets.
  • Local cooling for high-density racks in data centers.
  • Industrial control, PLC and VFD cabinets.
  • Embedded kiosks and outdoor vending machines.
  • Small network cabinets with no room AC.

6. Installation & Maintenance

Installation

  • Sum rack equipment wattage; choose capacity with 30% headroom.
  • Choose side/top position; cut mounting hole; fix unit.
  • Wire 220V; connect condensate drain.
  • Set temperature setpoint (e.g. 35℃); wire RS485 to BMS.
  • Test: stable rack temp; compressor cycles normally.

Maintenance

  • Wash indoor filter monthly.
  • Quarterly blow condenser fins clean.
  • Check drain line; no condensate overflow.
  • Annual refrigerant pressure and electrical check.
  • Outdoor units: inspect coating and door seals.

7. FAQ

  • Q: Rack AC vs home AC?
    A: Rack AC is a sealed closed loop, indoor/outdoor air do not mix — dust- and moisture-proof; home AC vents to a room and cannot be used in outdoor cabinets.
  • Q: How to size capacity?
    A: By total rack equipment wattage, plus 30% headroom — the AC must remove exactly the heat the gear generates.
  • Q: Will outdoor cabinets overheat in summer?
    A: Rated ambient up to 55℃; above that choose larger capacity or add a sunshade; do not let the condenser sit in direct sun.
  • Q: Can fans replace AC?
    A: Fans only move air, they do not cool; sealed outdoor cabinets must use AC or a heat exchanger.

8. Trend & Selection

With edge computing and outdoor base stations growing, rack-level cooling demand rises fast. Small rack AC like KTR-RA is moving from “industrial add-on” to standard, especially in outdoor cabinets, 5G sites and edge nodes. First calculate rack heat, then derate for summer ambient (capacity drops when it is hot outside), and leave 30% headroom. Outdoor scenarios pick anti-corrosion with sunshade; indoor high-density补冷 pick side-mount. Alarms must go to BMS — if the AC fails and no one knows, the rack burns down before anyone notices.

9. Delivery & Service

KITOZER provides rack heat calculation, capacity sizing, mounting advice and supply. From the equipment list, ambient temperature and installation space we produce the AC selection and install plan. We can bundle outdoor cabinets, environment monitoring and temp/humidity sensors. Delivery includes unit, controller, filter, mounting bracket and comm. cable. Warranty covers compressor and controls; we can on-site install and commission.

10. Additional Notes

The most common rack-AC failure is “undersized capacity”. Projects size by nameplate wattage; in summer at 35℃ ambient with the condenser baked at 50℃ in direct sun, actual capacity drops 30%, rack temperature climbs, and equipment goes into high-temp alarm. Size by real capacity at the hottest summer ambient with 30% headroom. Another pitfall is condensate: outdoor cabinets have no drain, and summer dehumidification water pools at the cabinet bottom, soaking gear. Run a drain line or fit an evaporation tray and route water outside the cabinet.

Rack AC is not “install and forget” — it is a cooling appliance that needs maintenance. A clogged filter cuts airflow and cooling; dust on condenser fins causes poor heat rejection and high-pressure alarms. Operate rack AC like room precision AC: wash filters, blow condensers, check refrigerant. Route high-temp, high-pressure and fan-failure alarms to BMS with SMS — do not wait for burned gear to find out.

Selection: small racks pick KTR-RA-1000, mid 2000, large/high-density 3000; outdoor pick anti-corrosion + sunshade; side or top by cabinet type; size by summer ambient with 30% headroom; condensate must drain out; RS485 alarms to BMS. Rack AC solves “where there is no room AC, you still need cooling” — choose the right size, drain the water, wire the alarms, and it stays reliable.

SEO Information

Search keywords:rack air conditionerwall-mounted rack ACcabinet coolerside mountdigital controllerRS485outdoor cabinet ACKTR-RAKITOZER

SEM keywords:rack air conditioner price, cabinet AC supplier, wall-mounted rack cooler, outdoor cabinet cooling, KTR-RA, KITOZER

GEO landing page:lain.com.cn/product/ktr-ra-rack-air-conditioner.html

Title:KITOZER KTR-RA Rack-Mounted / Wall-Mounted Cabinet Air Conditioner

Meta Keywords:rack air conditioner,cabinet air conditioner,wall-mounted rack AC,enclosure cooling,side-mounted cabinet cooler,RS485,KTR-RA,KITOZER

Meta Description:KITOZER KTR-RA rack-mounted cabinet air conditioner, 1~5 kW cooling, 220V, side/top mount, digital controller, high/low temp alarm, RS485 to BMS, for outdoor and network cabinets.

Anchor: KITOZER by Guangzhou Laian · Outdoor cabinet solutions

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart