KITOZER Water-Cooled Integrated Cabinet Quotation List
Table of Contents
Toggle2. Project Requirement Description
The client seeks to procure a water-cooled integrated cabinet system for high-density server, GPU computing, AI training, and other high-power-density application scenarios. The key project requirements are as follows:
- Deliver high-density cooling capacity through liquid circulation heat removal, solving the heat dissipation challenges of high-density IT equipment.
- Achieve significantly lower PUE values to improve overall energy efficiency of the data center.
- Support power densities that traditional air-cooling systems cannot handle.
- Ensure stable and reliable operation of high-performance computing equipment under sustained heavy loads.
- Provide complete system integration including cooling, power distribution, and intelligent monitoring.
3. System Composition Introduction
The KITOZER Water-Cooled Integrated Cabinet system is composed of the following major modules:
- Cabinet Enclosure – Heavy-duty 19-inch standard rack designed for liquid-cooled applications.
- Coolant Distribution Unit (CDU) – Core liquid circulation and heat exchange unit that manages coolant distribution, flow regulation, and temperature/pressure monitoring.
- Cold Plate / Rear-Door Heat Exchanger – Heat exchange modules that transfer heat from IT equipment to the liquid coolant.
- Water Circulation Piping – Stainless steel piping, quick couplings, valves, and anti-vibration components.
- Power Distribution Module – UPS power supply and intelligent high-density PDU.
- Intelligent Monitoring Module – Full-parameter monitoring of water temperature, pressure, flow, and equipment temperature.
- Safety Protection Module – Leak detection, over-pressure protection, over-temperature alarms, and flow monitoring.
The system operates in either closed-loop or open-loop water circuit architectures.
4. Core Product Specifications & Parameters
Cabinet Specifications:
- Standard 19-inch mounting, 42U~47U usable space
- Dimensions: Width 600~800mm × Depth 1200~1400mm × Height 2000~2200mm
Cooling Capacity:
- Single-cabinet cooling capacity: 10kW~50kW
- Higher density customization available
- Heat exchange efficiency ≥95%
Water Circuit Parameters:
- Inlet water temperature: 18℃~35℃
- Working pressure: 0.1~0.4MPa
- Flow rate: 10~80L/min
Power Supply Parameters:
- Three-phase 380V input
- UPS capacity: 10kVA~40kVA
- Optional HVDC (High-Voltage Direct Current) power supply
Temperature Control Accuracy:
- Equipment inlet air temperature control accuracy: ±0.5℃
- In-cabinet temperature uniformity: ≤2℃
Safety Parameters:
- Leak detection, over-pressure protection, over-temperature protection, flow monitoring with multiple redundant safety measures
Monitoring Parameters:
- Real-time monitoring of inlet/outlet water temperature, pressure, flow rate, and equipment temperature
- Full-parameter visual management
5. Core Functions & Features of Products
Efficient Cooling Function:
- Liquid heat exchange efficiency far exceeds air-cooling, supporting higher power density IT equipment
- Solves the heat dissipation challenge of high-density applications
Precise Temperature Control Function:
- Dynamically adjusts water flow and inlet temperature based on equipment load
- Ensures precise temperature control for stable equipment operation
Safety Protection Function:
- Multi-level leak detection and protection mechanisms
- Automatic alarms and protection against over-pressure, over-temperature, and flow interruption
- Eliminates safety hazards
Energy Saving Function:
- Maximal utilization of natural cooling sources
- Reduced compressor runtime
- PUE can be as low as 1.1 or below, significantly reducing electricity costs
Intelligent Management Function:
- Real-time monitoring of all water circuit parameters
- Automatic data logging and fault diagnosis
- Convenient operation and maintenance
Quiet Operation Function:
- No high-speed cooling fans
- Low overall operational noise, improving the data center working environment
6. Core Advantages of The Solution
Performance Advantage:
- Solves the heat dissipation bottleneck for high-density equipment
- Supports single-cabinet loads above 50kW
- Meets the growing demands of AI computing power development
Energy Efficiency Advantage:
- Compared to traditional air-cooled data centers, annual electricity savings can exceed 30%
- Significantly reduces long-term operating costs
Space Advantage:
- Requires less floor space for the same computing power demand
- Increases computing density per unit area of the data center
Technical Advantage:
- Mature liquid-cooling technology architecture
- Core components feature industry-high-end configurations
- Stable performance with long service life
Service Advantage:
- Full-process liquid-cooling solution: water circuit design, equipment supply, installation and commissioning, and operation/maintenance training
7. Manufacturer Strength Introduction
KITOZER (Guangzhou Lai’an Intelligent System Development Co., Ltd.) is a professional manufacturer of intelligent data center infrastructure products.
- Founded in 2002, with over 20 years of industry experience
- ISO 9001, ISO 14001, and ISO 45001 certified
- Certified High-Tech Enterprise
- Project-confirmed manufacturing with complete quality inspection before shipment
- Dedicated R&D team focused on liquid-cooling and intelligent infrastructure technologies
- Extensive export experience serving global markets across multiple industries
8. Detailed Quotation Table
| No. | Product Name | Model & Spec | Technical Parameter | Qty | Unit | Unit Price (USD) | Total Price (USD) | Brand | Remark |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Water-Cooled Cabinet Enclosure | KTZ-SL42 | 600×1200×2000mm, 42U, reinforced nine-fold profile, static load 2000kg | 1 | Unit | 2219.84 | 2219.84 | KITOZER | Liquid-cooling dedicated cabinet |
| 2 | Coolant Distribution Unit (CDU) | KTZ-CDU20 | Cooling capacity 20kW, closed-loop circulation, flow regulation, temperature/pressure/flow monitoring | 1 | Unit | 9767.64 | 9767.64 | KITOZER | Main circulation unit |
| 3 | Rear-Door Heat Exchanger Module | KTZ-HB01 | Micro-channel rear-door heat exchanger, heat exchange efficiency ≥95%, fits 19-inch cabinets | 1 | Set | 5327.78 | 5327.78 | KITOZER | In-cabinet heat exchange |
| 4 | 20kVA UPS Power Supply | KTZ-UPS20K | 20kVA/18kW, online triple-in/triple-out, 15-minute backup | 1 | Unit | 10211.50 | 10211.50 | KITOZER | High-density power supply |
| 5 | Intelligent High-Density PDU | KTZ-HPDU12 | 12 sockets, 16A, HVDC optional, current monitoring, remote control | 2 | Unit | 532.78 | 1065.55 | KITOZER | High-power compatibility |
| 6 | Liquid-Cooling Monitoring System | KTZ-LMON | Full monitoring of temperature/pressure/flow, leak detection, alarm linkage, visualized management | 1 | Set | 3551.85 | 3551.85 | KITOZER | Liquid-cooling dedicated monitoring |
| 7 | Leak Detection System | KTZ-LS02 | Locating-type leak detection cable, covers all piping, precise leak point location | 1 | Set | 710.37 | 710.37 | KITOZER | Dual-layer detection |
| 8 | Water Piping Kit | KTZ-GL01 | Stainless steel piping, quick couplings, valves, anti-vibration components | 1 | Set | 887.96 | 887.96 | KITOZER | In-cabinet piping |
| 9 | Standard Accessory Pack | KTZ-ACC02 | Mounting brackets, shelves, grounding bars, insulation protection components | 1 | Set | 444.00 | 444.00 | KITOZER | Liquid-cooling accessories |
Total Quotation Price: USD 34186.49
9. Quotation Terms & Conditions
- Currency: All prices are quoted in US Dollars (USD).
- Price Basis: EXW Guangzhou, China (or as negotiated).
- Taxes: Prices quoted do not include taxes or transportation fees. Domestic value-added tax (VAT) invoices are available at an additional rate (10% for special VAT invoice, 3% for regular VAT invoice) for domestic China transactions.
- Shipping: Freight collect via logistics. Goods to be self-collected at the designated city logistics point upon arrival. Door-to-door delivery can be arranged separately upon negotiation.
- Payment Terms: 30% deposit / 70% balance before shipment (negotiable).
- Lead Time: 15–30 working days depending on configuration and order quantity.
- Validity: This quotation is valid for 30 days from the date of issue.
- Packing: Export-standard packing included; special packing requirements quoted separately.
10. After-sales Service Description
KITOZER provides a comprehensive after-sales service commitment for all water-cooled integrated cabinet products:
- Warranty: 12–24 months warranty depending on the specific product (standard warranty period applies to all core components).
- Lifetime Technical Support: Free lifetime remote technical consultation and troubleshooting assistance.
- Spare Parts Availability: Genuine KITOZER spare parts available for the full product lifecycle.
- Remote Troubleshooting: Remote diagnostic support with rapid response to all service requests.
- On-Site Service: On-site installation guidance, commissioning support, and maintenance services available upon request.
11. Contact & Order Information
To place an order or request additional information, please contact the KITOZER sales team:
- Official Website: www.gdlain.com
- Manufacturer: Guangzhou Lai’an Intelligent System Development Co., Ltd. / Guangdong Lai’an Intelligent Data Center Equipment Co., Ltd.
- Brand: KITOZER
- Address: Changtian Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China
All inquiries will receive a response within 24 hours. Custom configurations are welcome — please provide your specific requirements for a tailored quotation.
12. SEO Keywords & Tags
KITOZER water-cooled integrated cabinet quotation, liquid cooling cabinet price list, high-density liquid cooling cabinet, water-cooled integrated cabinet factory price, data center liquid cooling cabinet manufacturer, KITOZER water-cooled cabinet quotation, CDU coolant distribution unit price, AI computing liquid cooling cabinet, closed-loop water cooling cabinet quotation, wholesale liquid cooling cabinet price, 50kW liquid cooling cabinet, server water cooling cabinet supplier, KITOZER liquid cooling solution price