KITOZER
KITOZER

KITOZER Water Leak Detection System Rope 10 Meter Positioning

Product Overview

The KITOZER water leak detection system is a complete leak sensing kit for data centers, server rooms, electrical substations, mechanical rooms, and basement storage areas where water intrusion could damage expensive equipment. The system consists of a positioning leak sensing cable, a leak detection controller, mounting clips, and a connector set. The sensing cable uses four parallel conductors isolated by a fluoropolymer jacket, and changes resistance when conductive water contacts the outer jacket, allowing the controller to detect not only the presence of a leak but also its exact position along the cable to within 1 meter accuracy. The controller reports the leak position over RS485 Modbus and triggers a local buzzer and a relay output that can shut down power to affected equipment or activate a shutoff valve.

The standard kit ships with 10 meters of sensing cable, but the controller supports up to 100 meters of cable per zone, and multiple controllers can be cascaded to cover larger rooms. The sensing cable is suitable for detecting water, diluted acids, alkalis, and conductive liquids, but not oil or non-conductive fluids. The cable can be cut to length on site, and each cut end must be terminated with the supplied end cap and a non-leak connector to maintain the positioning resistance chain.

Technical Specifications

Leak detection cable: 4 conductor fluoropolymer jacket, outer diameter 6.3 millimeters, minimum bend radius 30 millimeters, rated length per zone up to 100 meters, positioning accuracy plus or minus 1 meter, response time under 3 seconds. Controller: 1 zone standard, expandable to 4 zones, RS485 Modbus RTU output, 2 dry contact inputs, 2 relay outputs rated 30 V DC 2 A, local buzzer 85 dB, 0.96 inch OLED display showing leak position in meters. Supply voltage 9 to 24 V DC, typical consumption 2 W. Operating temperature minus 10 degrees Celsius to 60 degrees Celsius. Enclosure ABS, wall mount, 110 by 80 by 25 millimeters. Cable certification UL and CE. Two year warranty on controller, one year on sensing cable.

Application Scenarios

This leak detection system is installed along the perimeter of raised floors in data centers, under precision air conditioning units, along chilled water pipes in mechanical rooms, under rooftop pipe penetrations, along basement wall bases, in battery rooms where spill containment is required, and in retail storage areas where fire suppression water may accumulate. In a typical data center deployment, the sensing rope is laid in a loop around the CRAH unit, along the floor trench containing chilled water pipes, and below the ceiling pipe penetrations. When a pipe joint drips, the controller identifies the leak position to within one meter and sends the position to the KITOZER DCIM platform, which displays the exact cable distance on the floor plan so maintenance staff can walk directly to the leak without removing floor tiles across the entire room.

Key Advantages

The first advantage is positional awareness. Unlike simple spot detectors that only indicate that a leak exists somewhere, the KITOZER cable reports the distance along the rope, cutting troubleshooting time from hours to minutes. The second advantage is continuous coverage. The rope detects water anywhere along its entire length, rather than only at fixed points, so a slow drip at an unexpected pipe joint is still caught. The third advantage is easy retrofit. The cable is laid on the floor using adhesive clips, no cutting of floor tiles or drilling of walls is required, and the controller can be mounted on a DIN rail in the nearest cabinet. The fourth advantage is system integration. The Modbus RTU output and relay outputs allow the leak system to trigger automatic actions, such as closing a motorized shutoff valve on the chilled water loop or sending an immediate SMS to the facilities manager, without waiting for a central server to poll the alarm.

Installation and Maintenance Recommendations

Lay the sensing cable in a continuous loop along the likely leak paths, using the supplied adhesive clips to hold the cable 5 millimeters above the floor so water can reach it from below. Avoid tight bends that kink the cable, and avoid crossing the cable under heavy foot traffic where it may be crushed. Connect the controller to one end of the cable and fit the sealed end cap to the far end, taking care not to twist the conductors. During commissioning, perform a water test by placing a damp paper towel on the cable at three known positions along the rope and verifying that the controller reports the expected distance within 1 meter. Calibrate the zero position at the controller end of the cable and record the cable length in the monitoring software. Schedule semi-annual maintenance to inspect the cable for cracks, clean any dust from the sensing surface, and re-test the buzzer and relay by simulating a leak. After any leak event, dry the cable thoroughly with a cloth before resetting the alarm, because residual moisture on the jacket will keep the alarm active.

Price

From $185 per 10 meter kit including controller, rope, connectors, and clips. Contact +86 13922289957 for multi-zone kits, 50 meter and 100 meter cable rolls, and shutoff valve integration packages.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top