Table of Contents
ToggleProduct Overview
The KITOZER wet alarm check valve DN150 is the heart of a wet-pipe automatic sprinkler system, installed between the water supply riser and the branch sprinkler network. When a sprinkler opens due to heat, water flows through the valve, lifting the clapper and simultaneously sending water to the alarm port, which triggers a water motor gong and an electrical pressure switch. The valve maintains system pressure on the outlet side and allows a small bypass fill during normal thermal expansion. The KITOZER wet alarm valve is cast in ductile iron with epoxy coating, brass trim, and a stainless steel clapper seat, and is rated for 1.2 MPa working pressure. It is supplied with a pressure gauge, test and drain valves, a retarder chamber, and an alarm pressure switch. The unit fits commercial buildings, warehouses, hotels, hospitals, and factories where a permanently pressurized sprinkler network is acceptable and temperatures stay above freezing.
Technical Specifications
The DN150 flange-to-flange length is 470 mm, conforming to GB 5135 and ISO 6182 dimensions. Nominal pipe size is 150 mm, working pressure is 1.2 MPa, and maximum flow is 40 L per second at 0.1 MPa pressure drop. The clapper is stainless steel with a EPDM rubber seal, and the valve body is painted red RAL 3000. The alarm outlet is 20 mm BSP, fitted with a strainer, a retarder chamber of 0.5 L, and a pressure switch rated for 0.05 to 1.2 MPa, SPDT contacts at 5 A 250 VAC. The main drain is DN50, and the test connection is DN25. Operating temperature range is 4 to 70 degrees Celsius for the water side. KITOZER supplies the valve with an installation manifold, mounting brackets, pressure gauges on both supply and system sides, and a CE, LPCB, and CCCF certified nameplate.
Applications
The DN150 wet alarm valve is typically installed in the sprinkler riser rooms of mid-rise office buildings, shopping malls, hotels, hospitals, schools, factories, and warehouses. Each valve zone protects roughly 4,000 to 5,000 square meters of floor area depending on hazard classification. In large buildings, multiple zones share a common fire pump, and each wet alarm valve feeds its own floor or fire compartment. The valve is also used in parking garages, atriums, and industrial production halls where the temperature never drops below freezing.
Advantages and Features
KITOZER wet alarm valves offer four practical advantages. First, the epoxy-coated ductile iron body resists corrosion for decades, even in humid mechanical rooms. Second, the integrated retarder prevents false alarms from small pressure surges caused by pump cycling or water hammer, reducing nuisance alarm calls. Third, the clapper design provides a clear visual indication when the valve has flowed, which helps inspectors isolate zones after an event. Fourth, the pressure switch is field-adjustable and fully supervised, so the fire panel receives both alarm and trouble signals. KITOZER also provides a full range of spares including seats, clappers, and strainers, ensuring long-term support.
Installation and Maintenance Recommendations
Install the valve vertically with the arrow pointing in the direction of flow, in a clean, heated, well-lit riser room. Provide 500 mm clearance around the valve for service, and anchor the flanged connections to independent supports so pipe weight does not stress the body. After installation, slowly fill the system from the supply side, vent all high points, and verify that the clapper sits in the open position under normal pressure. Open the inspector test connection fully and confirm that the pressure switch alarms within 90 seconds and the water motor gong rings within 5 minutes. Quarterly, perform the inspector test and record pressure readings. Annually, inspect the strainer, flush the alarm line, and check the clapper seat for debris. Every five years, internally inspect the valve body and replace the EPDM seat. Price starts from $680 per DN150 valve assembly.
Ordering and Factory Support
KITOZER supplies wet alarm valves in DN50, DN80, DN100, DN150, DN200, and DN250 sizes, each with a matching trim set, pressure gauges, and test and drain valves. The factory ships each valve with a pressure test certificate, a mounting gasket kit, and an installation manual. For retrofit projects, KITOZER can also supply a complete riser trim package including the alarm valve, water motor gong, pressure switch, and manifold, reducing engineering coordination. Spare seals, clappers, and strainers are stocked locally for fast delivery. KITOZER also offers a complete wet, dry, and pre-action valve range, so consultants can standardize on one supplier for the entire sprinkler riser, simplifying spare parts inventory and staff training. The factory also provides a hydraulic calculation service for each zone, confirming pipe sizing and pump demand before procurement starts. KITOZER also supplies matching water motor gongs, alarm pressure switches, and test balls, so the entire riser trim can be ordered as one package with a single part number.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com