KITOZER
KITOZER

KITOZER Wet Quick Coupling: DN20 Stainless High Flow

System Integration Notes

When designing a cooling system around KITOZER quick couplings, it is important to size the port for the expected flow rate and pressure drop. Undersized couplings increase pumping energy and can cause uneven cooling across the rack. Plan for access clearance around each coupling for hand operation and visual inspection. Color-code supply and return lines at every connection point to eliminate cross-connection during maintenance. For mission-critical loops, carry spare seal cartridges and at least one complete coupling pair on site. KITOZER recommends documenting each coupling location, installation date, and cycle count in the facility maintenance register. When mixing coupling brands, verify poppet profile compatibility before deployment, as not all industry profiles are fully interchangeable. Training maintenance staff on proper engagement and disconnection technique reduces cycle wear and leak incidents.

Best Practices

For best results, KITOZER recommends establishing a quarterly inspection routine for all quick couplings in the cooling loop. During each inspection, cycle the coupling through three open-close motions to keep the poppet free and prevent sticking. Look for signs of weeping at the seal face, and check that the color-coded rings are intact. Replace any coupling that shows visible seal damage or repeated weeping. When planning maintenance, schedule coupling inspections during scheduled IT window changes, so that coupling health is verified at the same time as server swaps. Keep a maintenance log that records the date, coupling location, observed condition, and any action taken. Over time, this log reveals which couplings cycle most frequently and need proactive replacement. KITOZER also recommends training two staff members per shift on coupling operation, so that maintenance is not dependent on a single person. Proper training reduces mishandling that can cause seal damage or premature failure.

Price

From $120/pair. Contact +86 13922289957 for DN20 stainless wet coupling quote.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

The KITOZER DN20 stainless steel wet quick coupling combines high flow capacity with corrosion-resistant 316L construction for demanding cooling loops. The poppet design provides automatic shutoff on both sides, and the stainless steel body handles deionized water, high-purity glycol, and dielectric fluids. While not a true dry break, the coupling minimizes spillage to under 1 ml per disconnect, making it suitable for well-maintained mechanical rooms where drip trays are available. The DN20 size supports flow rates up to 80 liters per minute at 16 bar working pressure. KITOZER electropolishes the interior to reduce biofilm and fouling, and offers a helium leak test option for high-purity loop applications.

Product Overview

This coupling is selected when corrosion resistance is required but the premium price of a full dry break is not justified. The 316L stainless steel body with FKM seals handles aggressive coolants and high-purity loops. The poppet valve opens fully when connected, presenting low flow restriction. The coupling is available with threaded, barb, and flange terminations. A locking sleeve with safety latch prevents accidental disconnection. The body is electropolished for cleanability and reduced biofilm growth. The coupling is designed for wall or inline mounting, and accepts a panel-mount option for rack manifold installations. The flat exterior geometry allows the coupling to fit through standard panel cutouts.

Technical Specifications

Body: 316L stainless steel, electropolished interior, passivated to ASTM A967. Seal: FKM standard, EPDM option. Working pressure: 16 bar. Burst pressure: 64 bar. Flow coefficient Cv: 13. Temperature range: minus 20 to 150 degrees Celsius. Bore: DN20. Termination: G3/4 or G1 male thread, barb for 20 mm hose, flange DN20 PN16. Weight: 420 grams per pair. Spillage on disconnect: under 1 ml. Cycle life: 10,000 connect-disconnect cycles. Locking: sleeve lock with safety latch. Certification: CE, RoHS. KITOZER, 5 year warranty. Mill certificate: EN 10204 3.1. Helium leak test: option available.

Applications

Applications include secondary CDU loop connections, row manifold isolation, immersion cooling tank branches, semiconductor fab cooling, pharmaceutical process cooling, and power converter cooling. The coupling is also used in food and beverage process loops, biomedical research cooling, and scientific instrument cooling where 316L cleanliness is required but dry break spill-free performance is not. Additional installations include aerospace component test cooling, automotive battery pack validation, and renewable energy station power converter cooling. In HPC data centers, the DN20 wet coupling provides a cost-effective isolation point between the secondary loop and row manifolds, where occasional small spills are acceptable with drip trays in place.

Advantages and Features

The primary advantage is value: 316L corrosion resistance at a lower price than a full dry break. The high Cv of 13 reduces pumping energy and allows smaller pump selection. FKM seals tolerate a broad range of chemicals and temperatures up to 150 degrees Celsius. The coupling is rebuildable with replacement seal cartridges, extending service life. The electropolished interior reduces biofilm growth and fouling. The safety latch prevents accidental disconnection. Color-coded sleeves in blue and red speed up maintenance. The coupling is interchangeable with industry standard profiles, simplifying retrofit. The 316L construction resists pitting and crevice corrosion in chloride-containing environments.

Installation and Maintenance

Use PTFE tape on threaded connections and torque to 25 Nm. Support the coupling with pipe hangers; do not let the coupling carry pipe load. During disconnection, close upstream valves, depressurize, and place a drip tray beneath the coupling. Inspect FKM seals annually for hardness change, cracking, or chemical swelling. Replace seal cartridges at 5,000 cycles or every three years. Flush loops annually to remove sediment. Keep spare seal kits on site to minimize downtime. Record cycle count for each coupling to predict replacement needs. When installing on cold plates, use a wrench on the fitting hex to avoid side-load stress. After commissioning, monitor coolant resistivity quarterly if using deionized water, and replace filters as needed.

System Integration Notes

When designing a cooling system around KITOZER quick couplings, it is important to size the port for the expected flow rate and pressure drop. Undersized couplings increase pumping energy and can cause uneven cooling across the rack. Plan for access clearance around each coupling for hand operation and visual inspection. Color-code supply and return lines at every connection point to eliminate cross-connection during maintenance. For mission-critical loops, carry spare seal cartridges and at least one complete coupling pair on site. KITOZER recommends documenting each coupling location, installation date, and cycle count in the facility maintenance register. When mixing coupling brands, verify poppet profile compatibility before deployment, as not all industry profiles are fully interchangeable. Training maintenance staff on proper engagement and disconnection technique reduces cycle wear and leak incidents.

Best Practices

For best results, KITOZER recommends establishing a quarterly inspection routine for all quick couplings in the cooling loop. During each inspection, cycle the coupling through three open-close motions to keep the poppet free and prevent sticking. Look for signs of weeping at the seal face, and check that the color-coded rings are intact. Replace any coupling that shows visible seal damage or repeated weeping. When planning maintenance, schedule coupling inspections during scheduled IT window changes, so that coupling health is verified at the same time as server swaps. Keep a maintenance log that records the date, coupling location, observed condition, and any action taken. Over time, this log reveals which couplings cycle most frequently and need proactive replacement. KITOZER also recommends training two staff members per shift on coupling operation, so that maintenance is not dependent on a single person. Proper training reduces mishandling that can cause seal damage or premature failure.

Price

From $120/pair. Contact +86 13922289957 for DN20 stainless wet coupling quote.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart