KITOZER
KITOZER

Large and Medium-Small Data Center Solutions

Search Keywords, SEO and Tags

Core Search Keywords

Large Data Center Solution, Medium-Small Data Center Solution, Integrated Data Center Solution, Modular Data Center, Data Center System Configuration, Data Center Technical Parameters, Data Center Bidding Control Parameters, Green Data Center Solution, High-Reliability Data Center Deployment, Data Center Operation and Maintenance Solution

SEO Optimization Points

1. Core keywords are naturally distributed in the titles and main text of each module, with each core module containing at least 2-3 core keywords to avoid keyword stuffing; 2. The main text focuses on the practicality and technicality of the data center solution, highlighting system advantages, technical parameters, and application cases to improve content quality and user dwell time; 3. Reasonably set title levels (Level 1, Level 2, Level 3) to ensure a clear page structure for easy search engine crawling; 4. Tags cover core functions, application scenarios, and technical characteristics to improve page exposure; 5. Content revolves around users’ core needs (system stability, scalability, energy efficiency, compliance), addressing the actual pain points of data center construction, transformation, and operation and maintenance.

Tags

Data Center Solution, Large Data Center, Medium-Small Data Center, Modular Deployment, High-Reliability Data Center, Green Energy-Saving Data Center, Data Center System Configuration, Data Center Technical Parameters, Data Center Bidding Control, Data Center Application Cases, Data Center Operation and Maintenance, Data Center Security Protection

Part 1: Large Data Center Solution

I. System Introduction

The Large Data Center Solution is an end-to-end integrated solution designed for high computing power, high concurrency, and high reliability requirements. It integrates full-link resources such as computing, storage, network, power supply, cooling, security, and operation and maintenance, adopting modular architecture, intelligent management and control, and green energy-saving technologies. Strictly complying with national data center design specifications, this solution supports massive data storage, high-speed data transmission, and multi-service parallel processing, which can meet the core needs of ultra-large-scale service deployment, cross-regional data collaboration, and 24/7 continuous operation. It is suitable for large-scale computing power support scenarios in digital transformation, providing a solid infrastructure foundation for the stable operation, elastic expansion, and safety compliance of businesses.

Adopting a layered decoupling and modular design concept, this solution divides the entire data center system into six core levels: IT Infrastructure Layer, Power Supply System Layer, Cooling System Layer, Security Monitoring Layer, Intelligent Operation and Maintenance Layer, and Security Protection Layer. Each level operates independently and collaborates interactively, which not only ensures the stability and reliability of the system but also has extremely strong elastic expansion capabilities. It can gradually expand computing power, storage, and network resources according to business development needs to achieve “on-demand construction and flexible expansion”. At the same time, through technologies such as AI energy efficiency optimization and natural cold source utilization, it greatly reduces the PUE value of the data center, realizes green and low-carbon operation, balances both performance and energy saving goals, and helps achieve the “carbon peak and carbon neutrality” strategic requirements.

II. System Configuration List (Brand: KITOZER)

System LevelEquipment NameBrandSpecification Model (Universal Type)Quantity (Configurable on Demand)Purpose Description
IT Infrastructure LayerRack ServerKITOZER2U rack-mounted, ≥2 high-performance CPUs, ≥128GB DDR5 memory, support memory expansion up to 1TB, ≥4 pieces of 1.92TB NVMe SSD, ≥2 pieces of 10TB SATA HDD, support RAID 0/1/5/6/10, ≥4 1000BASE-T Gigabit Ethernet ports, ≥2 100Gbps optical portsOn DemandUndertake core computing tasks, support the operation of high-concurrency and high-computing-power businesses, such as big data analysis, AI training, and large-scale application deployment
Blade ServerKITOZERBlade architecture, ≥2 CPUs per blade, ≥64GB DDR5 memory, support memory expansion up to 512GB, ≥2 pieces of 1.92TB NVMe SSD, support blade cluster deployment, support hot swap, suitable for high-density computing scenariosOn DemandHigh-density computing nodes, improve computer room space utilization, suitable for ultra-large-scale computing power cluster deployment, reduce computer room occupation costs
Distributed Storage ArrayKITOZERSupport PB-level capacity expansion, ≥12 hard drives per node, support NVMe/SATA/SAS multiple hard drive types, support distributed redundant storage, read/write speed ≥10GB/s, latency ≤1ms, support data tiering storage and deduplicationOn DemandMass data storage, ensure high availability and reliability of data, support fast data reading and writing, suitable for mass data storage scenarios such as big data and video streams
All-Flash Storage ArrayKITOZERAll-NVMe architecture, ≥24 pieces of 3.84TB NVMe SSD, support RAID 0/1/5/6/10/50/60, read/write IOPS ≥1 million, latency ≤0.5ms, support multipath redundancy, support collaborative linkage with distributed storageOn DemandHigh-performance data storage, support low-latency businesses, such as core databases, real-time transactions, and AI inference scenarios
Network System LayerCore SwitchKITOZERModular core switch, ≥32 100Gbps QSFP28 optical ports, ≥64 40Gbps QSFP+ optical ports, support expansion up to 128 100Gbps ports, switching capacity ≥102.4Tbps, packet forwarding rate ≥76.8Mpps, support redundant backup, support SDN software-defined networkOn DemandCore network forwarding of data center, connect to aggregation layer switches, ensure high-speed data transmission, support multi-service isolation and traffic control
Aggregation SwitchKITOZER≥24 100Gbps QSFP28 optical ports, ≥48 10Gbps SFP+ optical ports, uplink ports support 100Gbps expansion, switching capacity ≥51.2Tbps, packet forwarding rate ≥38.4Mpps, support VLAN, ACL, QoS, support redundant linkage with core switchesOn DemandAggregate access layer traffic, forward to core switches, realize hierarchical network management and control, improve network stability and scalability
Access SwitchKITOZER≥48 10Gbps SFP+ optical ports, ≥4 100Gbps QSFP28 uplink optical ports, switching capacity ≥12.8Tbps, packet forwarding rate ≥9.6Mpps, support POE+ power supply (optional), support hot swap, support port aggregationOn DemandConnect IT equipment such as servers and storage, connect terminal equipment to the network, ensure equipment network connectivity and data transmission efficiency
FirewallKITOZERNext-generation firewall, throughput ≥100Gbps, concurrent connections ≥10 million, support Intrusion Detection System (IDS), Intrusion Prevention System (IPS), VPN, application identification, URL filtering, support dual-machine hot backup, support threat intelligence updateOn DemandNetwork border security protection, block malicious attacks and unauthorized access, ensure data center network security, and comply with relevant security standards
Power Supply System LayerUPS Uninterruptible Power SupplyKITOZERModular UPS, single unit capacity ≥200KVA, support parallel expansion up to 1000KVA, input voltage range 380V±15%, output voltage 380V±1%, backup time ≥30 minutes (expandable), support lithium battery/lead-acid battery, conversion efficiency ≥96%On DemandProvide uninterruptible power supply for core equipment when the commercial power is interrupted, ensure business continuity, and avoid data loss and equipment damage
Battery PackKITOZERValve-Regulated Sealed Lead-Acid Battery/Lithium Battery, capacity ≥100Ah, voltage 12V, cycle life ≥1500 times (lithium battery)/800 times (lead-acid), support temperature compensation, suitable for UPS uninterruptible power supply systemOn DemandStore electrical energy, provide backup power support for UPS, extend UPS power supply time, and ensure business continuous operation after commercial power interruption
Precision Power Distribution CabinetKITOZERInput voltage 380V, output voltage 220V/380V, support multiple output channels, equipped with precision monitoring instruments, support real-time monitoring of parameters such as current, voltage, power, and harmonics, support overload, short circuit, and leakage protection, support remote monitoringOn DemandDistribute power for IT equipment, cooling equipment, security equipment, etc., real-time monitor power parameters, and ensure safe and stable power supply
Diesel GeneratorKITOZERPower ≥1000KW, output voltage 380V, start-up time ≤15 seconds, fuel consumption ≤200g/KW·h, support automatic start-stop, support linkage with UPS, support remote monitoring, suitable for long-time commercial power interruption scenariosOn DemandProvide backup power for the entire data center when the commercial power is interrupted for a long time, ensure business continuous operation, and avoid losses caused by long-time power outage
Cooling System LayerPrecision Air ConditionerKITOZERComputer room-specific precision air conditioner, cooling capacity ≥120KW, air supply method: underfloor supply/upper return, temperature control accuracy ±0.5℃, humidity control accuracy ±5%RH, support frequency conversion energy saving, support dual-system redundancy, support remote monitoringOn DemandControl the temperature and humidity of the computer room, provide a stable operating environment for IT equipment, and avoid equipment failures caused by high temperature and high humidity
In-Row Air ConditionerKITOZERDeployed between rows, cooling capacity ≥40KW, air supply distance ≤5m, temperature control accuracy ±0.3℃, support hot and cold channel enclosure, support frequency conversion compressor, conversion efficiency ≥COP 4.0, support collaborative operation with precision air conditionersOn DemandCool server cabinets at close range, improve cooling efficiency, reduce energy consumption, suitable for high-density server cluster deployment scenarios
Fresh Air Ventilation SystemKITOZERVentilation volume ≥1000m³/h, support air filtration (filtration precision ≥PM2.5), support temperature and humidity preprocessing, support linkage with cooling system, support energy-saving mode switching, noise ≤55dBOn DemandIntroduce fresh air into the computer room, discharge polluted air, improve the air quality of the computer room, and use outdoor natural cold sources for energy saving to reduce cooling energy consumption
Security Monitoring LayerHD CameraKITOZER4K HD, pixels ≥8 million, viewing angle ≥120°, support infrared night vision (night vision distance ≥50m), support motion detection and abnormal alarm, support POE power supply, support remote viewing and video playbackOn DemandReal-time monitor the computer room entrances, exits and equipment areas, record the activities of personnel in the computer room and the operating status of equipment, and prevent unauthorized intrusion and equipment damage
Access Control SystemKITOZERSupport four identification methods: fingerprint, password, card swiping and face recognition, recognition accuracy ≥99.9%, support hierarchical authority management, support door opening record query, support abnormal door opening alarm, support linkage with monitoring systemOn DemandControl the authority of computer room entrances and exits, only authorized personnel can enter the computer room, ensure the physical security of the computer room, and prevent unauthorized access and data leakage
Environmental Monitoring SystemKITOZERSupport real-time monitoring of parameters such as temperature, humidity, smoke, water leakage, commercial power, and UPS status, equipped with sound and light alarms, support remote alarms (SMS, email), support data statistics and report exportOn DemandReal-time monitor the computer room environment and equipment operating status, timely detect abnormal situations and alarm, avoid fault expansion, and ensure stable system operation
Gas Fire Extinguishing SystemKITOZERAdopt heptafluoropropane fire extinguishing medium, no secondary pollution, fire extinguishing speed ≤10 seconds, support three start-up modes: automatic, manual and emergency, support linkage with smoke detectors, suitable for computer room fire extinguishing scenariosOn DemandQuickly extinguish fires when a fire breaks out in the computer room, protect IT equipment and data security, and avoid major losses caused by fires
Intelligent Operation and Maintenance LayerIntelligent Operation and Maintenance PlatformKITOZERSupport unified management and control of IT equipment, network equipment, power supply equipment, cooling equipment and security equipment, real-time monitor equipment operating status, support fault early warning, remote operation and maintenance, data statistics and report generation, support multi-terminal access1 SetRealize unified operation and maintenance of all equipment and scenarios in the data center, improve operation and maintenance efficiency, reduce operation and maintenance costs, and reduce manual intervention
Backup and Recovery SystemKITOZERSupport full backup, incremental backup and differential backup, backup speed ≥1TB/h, recovery speed ≥500GB/h, support cross-platform backup, support data encryption, support custom backup strategies, support off-site backupOn DemandBackup core data to prevent data loss, and quickly recover when data is damaged to ensure data security and business continuity

III. System Schematic Diagram

The large data center system adopts a layered architecture design, and each system collaborates interactively to form a complete infrastructure system. The schematic diagram is described below (text description, clearly presenting the connection relationship of each module, which can be directly used for visual design):

1. Overall Architecture: External Network → Firewall → Core Switch → Aggregation Switch → Access Switch → IT Infrastructure (Servers, Storage Arrays);

2. Power Supply Architecture: Commercial Power → Precision Power Distribution Cabinet → UPS Uninterruptible Power Supply (linked with Battery Pack) → Equipment of Each Level (IT Equipment, Cooling Equipment, Security Equipment); When the commercial power is interrupted, the diesel generator starts to supply power to the UPS and the entire system;

3. Cooling Architecture: Precision air conditioners and in-row air conditioners operate collaboratively, adopting a hot and cold channel enclosure design. The fresh air ventilation system introduces natural cold sources and links with the cooling system to achieve precise control of the computer room temperature and humidity;

4. Security Architecture: HD cameras, access control systems, environmental monitoring systems and gas fire extinguishing systems are linked to real-time monitor the physical security and environmental status of the computer room, and automatically alarm and trigger emergency handling in case of abnormalities;

5. Operation and Maintenance Architecture: The intelligent operation and maintenance platform uniformly accesses IT equipment, network equipment, power supply equipment, cooling equipment and security equipment to realize real-time monitoring of equipment operating status, fault early warning, remote operation and maintenance, and data statistics; The backup and recovery system is linked with IT equipment to realize backup and rapid recovery of core data;

6. Security Architecture: The firewall is responsible for network border protection, the intrusion detection/defense system monitors internal network abnormalities, data encryption technology ensures the security of data transmission and storage, and hierarchical authority management ensures operation and maintenance security, forming a three-layer security system of “border protection + internal control + data security”.

IV. Product Technical Parameters (Brand: KITOZER)

(I) Technical Parameters of IT Infrastructure Layer Products

Equipment NameCore Technical Parameters
Rack Server1. Form: 2U rack-mounted, supporting 19-inch standard cabinet installation; 2. CPU: ≥2 high-performance multi-core CPUs, main frequency ≥2.5GHz, core number ≥24 cores, supporting CPU expansion up to 4 pieces; 3. Memory: ≥128GB DDR5 4800MHz ECC memory, supporting memory expansion up to 1TB, memory slots ≥16; 4. Storage: ≥4 pieces of 1.92TB NVMe SSD (read speed ≥3500MB/s, write speed ≥3000MB/s), ≥2 pieces of 10TB SATA HDD (7200 rpm, cache ≥256MB), supporting RAID 0/1/5/6/10, hard drive slots ≥12; 5. Network: ≥4 1000BASE-T Gigabit Ethernet ports, ≥2 100Gbps optical ports, supporting wake-on-LAN and link aggregation; 6. Power Supply: Redundant dual power supplies, power ≥1600W, conversion efficiency ≥94%, supporting hot swap; 7. Operating System: Supporting mainstream server operating systems, compatible with virtualization platforms; 8. Reliability: MTBF ≥100000 hours, supporting hot swap of hard drives, power supplies and fans, supporting fault early warning.
Blade Server1. Form: Blade-type, suitable for standard blade cabinets, each cabinet supporting ≥16 blade nodes; 2. CPU: ≥2 high-performance multi-core CPUs per blade, main frequency ≥2.3GHz, core number ≥20 cores, supporting CPU expansion; 3. Memory: ≥64GB DDR5 4800MHz ECC memory per blade, supporting memory expansion up to 512GB, memory slots ≥8; 4. Storage: ≥2 pieces of 1.92TB NVMe SSD per blade, supporting RAID 0/1, hard drive slots ≥4; 5. Network: ≥2 100Gbps uplink optical ports per blade, supporting linkage with cabinet switches, supporting SDN; 6. Power Supply: Centralized cabinet power supply, redundant power supply modules, each module power ≥2000W, conversion efficiency ≥95%; 7. Heat Dissipation: Centralized cabinet heat dissipation, supporting intelligent speed regulation fans, suitable for high-density deployment; 8. Reliability: MTBF ≥90000 hours, supporting blade hot swap, supporting automatic fault switching.
Distributed Storage Array1. Architecture: Distributed cluster architecture, supporting horizontal node expansion, maximum supporting ≥100 nodes; 2. Capacity: ≥12 hard drives per node, supporting NVMe/SATA/SAS multiple hard drive types, single node capacity ≥100TB, cluster total capacity supporting PB-level expansion; 3. Performance: Read/write speed ≥10GB/s, random read/write IOPS ≥100000, latency ≤1ms; 4. Data Protection: Supporting distributed redundant storage (replica number ≥3), supporting data tiering storage, deduplication and data compression, supporting automatic recovery of faulty nodes; 5. Interface: Supporting multiple interfaces such as iSCSI, FC, NFS and CIFS, compatible with mainstream operating systems and virtualization platforms; 6. Management: Supporting Web-based management, real-time monitoring of storage node status, supporting fault early warning and remote operation and maintenance; 7. Reliability: MTBF ≥120000 hours, supporting node hot swap, no single point of failure.
All-Flash Storage Array1. Architecture: All-NVMe architecture, supporting dual-controller redundancy, controller cache ≥128GB; 2. Capacity: ≥24 pieces of 3.84TB NVMe SSD, supporting hard drive expansion up to 48 pieces, total capacity ≥180TB; 3. Performance: Sequential read speed ≥20GB/s, sequential write speed ≥15GB/s, random read/write IOPS ≥1 million, latency ≤0.5ms; 4. Data Protection: Supporting RAID 0/1/5/6/10/50/60, supporting data snapshot, cloning and remote replication, supporting AES-256 data encryption; 5. Interface: Supporting interfaces such as FC, iSCSI and NVMe-oF, supporting 16Gbps FC and 100Gbps Ethernet; 6. Management: Supporting intelligent operation and maintenance, real-time monitoring of storage status, supporting automatic fault switching, supporting report generation; 7. Reliability: MTBF ≥150000 hours, dual-controller redundancy, no single point of failure, supporting hard drive hot swap.

(II) Technical Parameters of Network System Layer Products

Equipment NameCore Technical Parameters
Core Switch1. Form: Modular core switch, 19-inch rack-mounted, height ≥4U; 2. Ports: ≥32 100Gbps QSFP28 optical ports, ≥64 40Gbps QSFP+ optical ports, supporting expansion up to 128 100Gbps ports; 3. Performance: Switching capacity ≥102.4Tbps, packet forwarding rate ≥76.8Mpps, supporting wire-speed forwarding; 4. Functions: Supporting protocols such as VLAN, ACL, QoS, VRRP, BGP and OSPF, supporting SDN software-defined network, supporting network virtualization, supporting traffic control and load balancing; 5. Redundancy: Supporting dual main control boards and dual power supply redundancy, supporting hot swap, automatic fault switching; 6. Reliability: MTBF ≥100000 hours, supporting lightning protection and surge protection, operating temperature range 0-45℃; 7. Management: Supporting Web-based and CLI command line management, supporting remote monitoring and fault early warning.
Aggregation Switch1. Form: Rack-mounted aggregation switch, 19-inch rack-mounted, height ≥2U; 2. Ports: ≥24 100Gbps QSFP28 optical ports, ≥48 10Gbps SFP+ optical ports, uplink ports supporting 100Gbps expansion; 3. Performance: Switching capacity ≥51.2Tbps, packet forwarding rate ≥38.4Mpps, supporting wire-speed forwarding; 4. Functions: Supporting VLAN, ACL, QoS, link aggregation and VRRP, supporting redundant linkage with core switches, supporting traffic statistics and mirroring; 5. Redundancy: Supporting dual power supply redundancy, supporting hot swap, automatic fault switching; 6. Reliability: MTBF ≥90000 hours, supporting lightning protection and surge protection, operating temperature range 0-45℃; 7. Management: Supporting Web-based and CLI command line management, supporting remote monitoring and fault reporting.
Access Switch1. Form: Rack-mounted access switch, 19-inch rack-mounted, height ≥1U; 2. Ports: ≥48 10Gbps SFP+ optical ports, ≥4 100Gbps QSFP28 uplink optical ports, supporting port aggregation; 3. Performance: Switching capacity ≥12.8Tbps, packet forwarding rate ≥9.6Mpps, supporting wire-speed forwarding; 4. Functions: Supporting VLAN, ACL, QoS, port mirroring and link aggregation, supporting POE+ power supply (optional, single port power supply ≥30W); 5. Redundancy: Supporting dual power supply redundancy (optional), supporting hot swap, supporting uplink link redundancy; 6. Reliability: MTBF ≥80000 hours, supporting lightning protection and surge protection, operating temperature range 0-45℃; 7. Management: Supporting Web-based and CLI command line management, supporting remote monitoring and batch configuration.
Firewall1. Form: Rack-mounted next-generation firewall, 19-inch rack-mounted, height ≥2U; 2. Performance: Throughput ≥100Gbps, concurrent connections ≥10 million, new connections per second ≥100000; 3. Functions: Supporting Intrusion Detection System (IDS), Intrusion Prevention System (IPS), VPN (supporting IPsec and SSL VPN), application identification (identifying ≥5000 types of applications), URL filtering, email filtering and DDoS protection; 4. Security: Supporting AES-256 encryption, supporting threat intelligence update, supporting abnormal traffic analysis, supporting dual-machine hot backup; 5. Interfaces: ≥8 100Gbps optical ports, ≥16 10Gbps optical ports, supporting interface expansion; 6. Reliability: MTBF ≥90000 hours, supporting dual power supply redundancy, supporting hot swap, operating temperature range 0-45℃; 7. Management: Supporting Web-based and CLI command line management, supporting remote monitoring, fault early warning and log auditing.

(III) Technical Parameters of Power Supply System Layer Products

Equipment NameCore Technical Parameters
UPS Uninterruptible Power Supply1. Architecture: Modular UPS, supporting parallel expansion, single unit capacity ≥200KVA, maximum expandable up to 1000KVA; 2. Input Parameters: Input voltage 380V±15%, input frequency 50Hz±5%, input power factor ≥0.98; 3. Output Parameters: Output voltage 380V±1%, output frequency 50Hz±0.1%, output power factor ≥0.9, conversion efficiency ≥96%; 4. Backup Time: ≥30 minutes (standard configuration battery pack), supporting extension of backup time to several hours; 5. Battery: Supporting lead-acid battery/lithium battery, supporting real-time monitoring of battery status, supporting battery charge and discharge protection; 6. Functions: Supporting online double conversion, supporting automatic switching between commercial power/battery modes, supporting overload, short circuit and over-temperature protection, supporting remote monitoring; 7. Reliability: MTBF ≥80000 hours, supporting module hot swap, automatic fault switching, operating temperature range 0-40℃.
Battery Pack1. Type: Valve-Regulated Sealed Lead-Acid Battery/Lithium Battery (optional); 2. Specification: Capacity ≥100Ah, voltage 12V, single cell size suitable for standard battery cabinets; 3. Performance: Cycle life ≥1500 times (lithium battery)/800 times (lead-acid battery), depth of discharge ≥80%, self-discharge rate ≤3%/month (25℃); 4. Environment: Operating temperature range -10℃~45℃, supporting temperature compensation, suitable for UPS uninterruptible power supply system; 5. Security: Supporting overcharge,
Shopping Cart