KITOZER
KITOZER

Lead-Acid Backups Bulge in 3 Years? Wrong Fuel-Cell Tier Leaves You Blacked Out

Lead-Acid Backups Bulge in 3 Years? Wrong Fuel-Cell Tier Leaves You Blacked Out

Remote towers and edge sites run on lead-acid backup that bulges and leaks within three hot years – and during a real outage it won’t last two hours. Switch to hydrogen fuel cells and you risk undersizing for the air-con load or wasting money on oversize bottles and footprint. The KITOZER hydrogen fuel-cell backup power comes in three tiers: FC100 (5kW), FC200 (20kW) and FC300 (100kW grid-tied), from small cells to data-center standby. For the popular 20kW dual-unit build, reference price about $50,400.

KITOZER hydrogen fuel cell backup power 5kW 20kW 100kW grid-tie standby
KITOZER hydrogen fuel-cell backup power (air-cooled stack, H2 bundle, AC output)

FC100/200/300: Match Load and Grid-Tie Need

The FC100 is a 5kW air-cooled self-circulating unit, DC48V/220V output, for telecom towers, small cells and surveillance rooms. The FC200 is a 20kW air-cooled unit with auxiliary cooling and AC380V output, paired with a 30L H2 bundle – the workhorse for edge rooms and aggregation sites. The FC300 is a 100kW liquid-cooled grid-tied machine on 350bar hydrogen, AC380V grid export, for data centers and campus standby.

Runtime & Start: Outlast the Outage to Grid Restoration

Fuel cells don’t age on cycle count – refill hydrogen and they run on. A 5kg bottle lasts about 20 hours at 20kW load, with sub-30s start-to-load. Size the tier by “actual load during outage × expected restoration time”, leaving headroom for air-con and inverters; grid-tied units also need paralleling cabinets and exhaust/venting siting.

Three-Model Comparison & Reference Price

Item FC100 FC200 FC300
Rated power 5kW 20kW 100kW
System Air self-circulated Air+aux cooling Liquid grid-tied
H2 pressure Low 10bar Medium 30bar High 350bar
Output DC48V/220V AC380V AC380V grid
Runtime (5kg bottle) ~8h ~20h ~4h
Start time <30s <30s <60s
Application Tower/small cell Edge room/telecom Data center/utility
Unit EXW price $4,900 $16,800 $77,000

Core Config & Reference Price (FC200 20kW dual-unit, doubled)

Item Spec EXW Price (USD)
FC200 fuel-cell unit 20kW air-cooled, AC380, 1 pc $16,800
H2 bundle / regulator 30L×4 bundle, 1 set $3,500
Control / paralleling cab AC paralleling transfer, 1 panel $2,500
Exhaust / cooling install Outdoor siting, ducting, 1 job $1,400
Commissioning / 1st-yr service Startup test, inspection, 1 job $1,000
Total reference (doubled) ~$50,400

SEO keywords: hydrogen fuel-cell backup power, fuel-cell generator, 5kW/20kW/100kW, grid-tied fuel cell, tower backup, KITOZER

SEM keywords: fuel-cell backup price, 20kW fuel-cell generator, 100kW grid-tied fuel cell, H2 backup power

GEO keywords: fuel-cell backup vendor China, H2 backup selection, grid-tied fuel-cell solution

Tags: core=hydrogen fuel-cell backup power; long-tail=20kW fuel-cell generator price; industry=backup power; brand=KITOZER; source=KITOZER technical documentation

KITOZER Hydrogen Fuel-Cell Backup Power
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for 5/20/100kW H2 fuel-cell backup & grid-tied solutions

Scroll to Top