Lead-Acid Battery Solution for Server Rooms (Brand: KITOZER)

Table of Contents

I. System Introduction

1.1 System Overview

The lead-acid battery system for server rooms serves as the core energy storage unit to guarantee uninterrupted power supply for data centers, telecommunication rooms and all types of critical IT facilities. As the energy reserve core of UPS (Uninterruptible Power Supply) systems, it instantly delivers stable DC power once utility power fails or malfunctions, ensuring continuous operation of loads and preventing data loss and business downtime. Renowned for outstanding performance and reliability, KITOZER lead-acid batteries are the ideal choice for server room UPS systems and widely deployed across various critical infrastructure sectors.

1.2 System Working Principle

The KITOZER lead-acid battery system operates based on a three-phase cycle: Charging – Energy Storage – Discharging.

  • Normal utility power: The UPS rectifier converts AC power into DC power, which supplies power to the inverter and maintains the battery bank via float charging to keep batteries fully charged.
  • Abnormal utility power: The battery bank immediately discharges power to loads through the inverter. The switching time is less than 4ms with zero interruption to keep equipment running.
  • Utility power recovery: The system automatically switches back to mains mode and resumes float charging for the battery bank to get ready for future power outages.
lead acid battery solution for server rooms (9)

1.3 Core System Values

Core ValueDetailed Description
Zero-interruption ProtectionMillisecond-level switching response prevents unexpected power cuts for critical devices and secures data.
Stable Power SupplyOutput voltage fluctuation is controlled within ±1%, delivering pure power for sensitive IT equipment.
Wide Environmental AdaptabilityDesigned for a wide temperature range of -10℃ ~ 45℃, adaptable to various server room conditions.
Long Service LifeDesigned float life reaches 10 to 15 years at 25℃, cutting total lifecycle costs.
High Safety & ReliabilityAdopts valve-regulated sealed technology with zero risk of electrolyte leakage and built-in multi-protection mechanisms.

II. System Composition

The KITOZER lead-acid battery system consists of the following core components that work jointly to ensure stable operation.

Component NameFunction Description
Lead-Acid Battery BankCore energy storage unit composed of multiple single batteries connected in series to provide required DC voltage and capacity.
Battery Management System (BMS)Real-time monitoring of voltage, current, temperature, internal resistance and other parameters of each cell; enables intelligent charge-discharge management and fault early warning.
Battery Connection AssembliesIncluding busbars, connecting cables and insulators to ensure reliable connection and safe isolation of the battery bank.
Battery Cabinet / RackProvides physical support, protection and heat dissipation. Designed with insulation, fire resistance and ventilation to fit server room layouts.
Battery Protection DevicesIncluding fuses, circuit breakers and surge protectors to prevent overcurrent, short circuit, overvoltage and other faults.
Ventilation & Heat Dissipation SystemMaintains proper operating temperature for batteries to extend service life and improve system stability.
Monitoring & Communication InterfacesSupports RS485, Modbus and other protocols for seamless connection with UPS hosts and server room environment monitoring systems.
lead acid battery solution for server rooms (8)

III. System Classification

3.1 Classification by Battery Type

CategoryTechnical FeaturesApplication Scenarios
Valve-Regulated Lead-Acid Battery (VRLA)Low-liquid design, internal oxygen cycle, maintenance-free sealing, no acid mist emission and high safety.General server rooms, small & medium data centers, telecommunication base stations.
Gel Lead-Acid BatteryGel electrolyte, good thermal stability, excellent deep cycle performance and strong vibration resistance.Server rooms in extreme environments, long-term unattended sites.
Flooded Lead-Acid BatteryTraditional design requiring regular maintenance with low cost for specific applications.Large data centers, scenarios with frequent charge and discharge cycles.

3.2 Classification by Installation Method

CategoryFeaturesApplication Scenarios
Vertical InstallationSingle-cell standalone installation with large floor space occupancy; suitable for spacious rooms.Large data centers, dedicated battery rooms.
Rack-Mounted InstallationStandard 3U/6U rack design, space-saving and easy for centralized management.Small & medium server rooms, integrated cabinet systems.
Containerized InstallationIntegrated inside standard containers for outdoor deployment and modular expansion.Edge data centers, temporary server rooms.

3.3 Classification by Capacity Level

Capacity LevelTypical Applications
Small Capacity (≤100Ah)Desktop UPS, small network rooms, edge computing nodes.
Medium Capacity (100Ah–500Ah)Small & medium data centers, enterprise server rooms, telecommunication rooms.
Large Capacity (≥500Ah)Large data centers, cloud computing centers, supercomputer centers.
lead acid battery solution for server rooms (6)

IV. System Configuration List (KITOZER)

4.1 Standard Configuration by Power Rating

4.1.1 Supporting System for 10kVA UPS

No.Device NameModelBrandQtyUnitRemarks
1Valve-Regulated Sealed Lead-Acid BatteryNP12-100KITOZER8Cells12V/100Ah, 10-year float life @ 25℃
2Battery Monitoring & Management ModuleK-BMS-16KITOZER1SetSupports 16-cell monitoring, RS485 communication
3Battery Connecting CableKC-16-500KITOZER1Set16mm² copper core, 500mm length
4Battery BusbarKB-1000KITOZER1SetMatches 100Ah battery bank
5Battery CabinetKBC-8KITOZER1SetHolds 8 cells, with ventilation & heat dissipation
6Battery Protection DeviceKBP-63KITOZER1Set63A circuit breaker + surge protection
7Temperature SensorKT-100KITOZER2PcsMonitors battery bank temperature
8Communication ModuleKCM-485KITOZER1PcModbus protocol, UPS communication interface

4.1.2 Supporting System for 20kVA UPS

No.Device NameModelBrandQtyUnitRemarks
1Valve-Regulated Sealed Lead-Acid BatteryNP12-150KITOZER16Cells12V/150Ah, 12-year float life @ 25℃
2Battery Monitoring & Management ModuleK-BMS-32KITOZER1SetSupports 32-cell monitoring, LCD display
3Battery Connecting CableKC-25-600KITOZER1Set25mm² copper core, 600mm length
4Battery BusbarKB-1500KITOZER2SetsMatches 150Ah battery bank
5Battery CabinetKBC-16KITOZER2Sets8 cells per cabinet, intelligent heat dissipation
6Battery Protection DeviceKBP-100KITOZER1Set100A circuit breaker + multi-level surge protection
7Temperature SensorKT-100KITOZER4PcsDistributed temperature monitoring
8Communication ModuleKCM-485KITOZER1PcModbus protocol, remote monitoring supported
9Insulation Monitoring DeviceKIM-200KITOZER1SetReal-time insulation status monitoring

4.1.3 Supporting System for 50kVA UPS

No.Device NameModelBrandQtyUnitRemarks
1Valve-Regulated Sealed Lead-Acid BatteryNP2-1000KITOZER48Cells2V/1000Ah, 15-year float life @ 25℃
2Battery Monitoring & Management SystemK-BMS-64KITOZER1SetSupports 64-cell monitoring, Web management interface
3Battery Connecting CableKC-50-800KITOZER1Set50mm² copper core, 800mm length
4Battery BusbarKB-2000KITOZER4SetsMatches 1000Ah battery bank
5Battery RackKBF-48KITOZER1SetHolds 48 cells, with ventilation system
6Battery Protection DeviceKBP-250KITOZER1Set250A circuit breaker, intelligent protection
7Temperature SensorKT-200KITOZER8PcsHigh-precision temperature monitoring
8Communication GatewayKCG-100KITOZER1SetMulti-protocol conversion supported
9Insulation Monitoring DeviceKIM-500KITOZER1SetMulti-channel insulation monitoring
10Fire Linkage ModuleKFM-100KITOZER1PcLinked with server room fire protection system
lead acid battery solution for server rooms (5)

V. System Schematic Diagram

5.1 Block Diagram of KITOZER Lead-Acid Battery System

Utility Input → UPS Rectifier ─┬→ Inverter → Load Devices

                 │

                 └→ KITOZER Lead-Acid Battery Bank (Float Charging)

                       ↑

                       │

               Battery Management System (BMS)

                       ↑

                       │

               Environment Monitoring System (Remote Monitoring)

5.2 Detailed Working Process

  1. Normal Mode: Utility power is converted into DC power by the rectifier. One branch supplies the inverter for stable AC output, while the other float-charges the KITOZER battery bank. BMS monitors battery status in real time.
  2. Power Failure Mode: BMS detects mains abnormality and triggers immediate battery discharge. Power is delivered to loads via the inverter with seamless switching.
  3. Fault Protection Mode: BMS automatically cuts off the battery circuit when low voltage, over temperature or short circuit occurs, protecting the battery bank and UPS equipment.
  4. Remote Monitoring Mode: BMS uploads battery data to the environment monitoring system via communication interfaces for remote monitoring, alarm and data analysis.
lead acid battery solution for server rooms (4)

VI. Product Technical Parameters

6.1 Parameters of KITOZER Valve-Regulated Sealed Lead-Acid Batteries

Parameter CategoryParameter NameNP12 Series (12V)NP2 Series (2V)
Basic ParametersRated Voltage12V2V
Rated Capacity7Ah/17Ah/24Ah/38Ah/65Ah/100Ah/150Ah200Ah/500Ah/1000Ah/2000Ah/3000Ah
Battery TypeValve-Regulated Sealed Lead-Acid (VRLA)Valve-Regulated Sealed Lead-Acid (VRLA)
Plate TypeLead-Calcium Multi-Alloy PlateLead-Calcium Multi-Alloy Plate
Electrolyte TypeLow-liquid / GelLow-liquid / Gel
Electrical PerformanceFloat Charging Voltage13.5–13.8V (@25℃)2.23–2.27V (@25℃)
Equalizing Charging Voltage14.4–14.7V (@25℃)2.35–2.40V (@25℃)
Max. Charging Current0.25C100.25C10
Max. Discharging Current3C10 (5 seconds)3C10 (5 seconds)
Internal Resistance≤8mΩ (100Ah)≤0.5mΩ (1000Ah)
Environmental AdaptabilityOperating Temperature Range-10℃ ~ 45℃-10℃ ~ 45℃
Optimal Operating Temperature25℃25℃
Relative Humidity≤90% (@20℃)≤90% (@20℃)
Altitude≤1000m≤1000m
Lifespan ParametersDesigned Float Life10–12 years (@25℃)12–15 years (@25℃)
Cycle Life≥1000 cycles (80% DOD)≥1200 cycles (80% DOD)
Safety ParametersSafety Valve Opening Pressure10–35kPa10–35kPa
Explosion-Proof RatingIP21IP21
Flame Retardant RatingUL94 V-0UL94 V-0
Physical ParametersDimensions (mm)Varies by capacityVaries by capacity
Weight (kg)Varies by capacityVaries by capacity
Terminal TypeBolt / TabBolt

6.2 Parameters of KITOZER Battery Management System (BMS)

Parameter NameTechnical Specifications
Monitoring Channels16/32/64 channels, expandable
Monitored ItemsVoltage, current, temperature, internal resistance, SOC, SOH
Measurement AccuracyVoltage: ±0.5%FS; Temperature: ±1℃; Current: ±1%FS
Communication InterfacesRS485 (Modbus RTU), Ethernet (Modbus TCP/IP)
Operating VoltageDC12V / 24V
Operating Temperature-20℃ ~ 60℃
Protection RatingIP30
Alarm ModesAudible & visual alarm, dry contact output, remote alarm
Data StorageSupports historical data storage and export for analysis
lead acid battery solution for server rooms (3)

VII. Application Scope

7.1 Core Application Fields

Application FieldSpecific ScenariosApplication Value
Data CenterLarge cloud data centers, financial data centers, enterprise data centersEnsures continuous operation of server clusters and storage devices, prevents data loss.
Telecommunication RoomsTelecom operator rooms, 5G base stations, core network roomsGuarantees uninterrupted operation of communication equipment and stable network.
Industrial ControlAutomated production lines, DCS systems, PLC control centersAvoids production downtime and maintains continuous industrial processes.
Medical EquipmentOperating room devices, ICU monitoring systems, medical imaging equipmentKeeps life-support devices running to save lives.
Financial InstitutionsBank data centers, ATM systems, payment clearing systemsPrevents financial transaction interruptions and secures capital.
Government AgenciesGovernment cloud platforms, emergency command centers, confidential roomsEnsures continuous government services and national security.
Energy IndustrySubstations, power plant DCS systems, new energy monitoring centersMaintains stable power system operation and prevents grid accidents.

7.2 Applicable UPS Types

KITOZER lead-acid battery systems are compatible with all mainstream UPS topologies:

  • Online UPS: Adopts double-conversion technology to deliver the highest level of power protection for scenarios requiring strict power quality.
  • Line-Interactive UPS: Features voltage regulation to reduce battery cycling frequency, suitable for general server rooms.
  • Standby UPS: Simple structure and low cost, applied to scenarios with low requirements on power continuity.
lead acid battery solution for server rooms (2)

VIII. Product Advantages

8.1 Core Competitive Strengths

Advantage CategoryDetailed Description
High ReliabilityLead-calcium multi-alloy plates are adopted; cycle life reaches 1000–1200 cycles and float life is 10–15 years @ 25℃.
Excellent PerformanceHigh-power discharge capability meets instantaneous high power demand of data centers for smooth equipment switching.
Safety & Environmental ProtectionValve-regulated sealed design eliminates electrolyte leakage and acid mist emission, fully complying with environmental standards.
Low MaintenanceMaintenance-free design with no need for distilled water refilling, cutting O&M costs and fitting long-term unattended sites.
Strong Environmental AdaptabilityWide operating temperature range (-10℃ ~ 45℃); retains over 80% capacity even at low temperatures.
Intelligent ManagementMatched BMS monitors battery status in real time, gives early fault warnings and extends service life.
High CompatibilityCompatible with mainstream UPS brands and supports parallel expansion to meet various power demands.
Cost-EffectiveLow total lifecycle cost with short return on investment cycle.

8.2 Comparison with Other Energy Storage Technologies

Comparison ItemKITOZER Lead-Acid BatteryLithium Battery
ReliabilityExtremely high, mature technology with low failure rateHigh, requiring sophisticated management systems
SafetyNo thermal runaway risk, high safetyPotential thermal runaway risk, strict management required
Environmental AdaptabilityWide temperature range (-10℃ ~ 45℃), good low-temperature performancePoor low-temperature performance with severe capacity attenuation
Maintenance CostMaintenance-free, low costRequires professional maintenance, high cost
Cycle Life1000–1200 cycles (80% DOD)2000–3000 cycles (80% DOD)
Float Life10–15 years (@25℃)5–8 years
Initial InvestmentLowHigh
Recycling ValueHigh, mature recycling systemLow, high recycling cost
lead acid battery solution for server rooms (1)

IX. Bid Control Parameters

9.1 Core Bid Parameters for Batteries

Control ItemTechnical Requirements
Brand RequirementMust be KITOZER brand; original manufacturer authorization certificate is required.
Product TypeValve-Regulated Sealed Lead-Acid Battery (VRLA); open-type batteries are prohibited.
Capacity ToleranceCapacity deviation ≤ ±3% based on matching UPS power.
Lifespan RequirementDesigned float life ≥ 10 years @ 25℃; cycle life ≥ 1000 cycles (80% DOD).
Safety StandardComplies with GB/T 19638.2; certified by UL and CE.
Temperature AdaptabilityOperating range: -10℃ ~ 45℃; capacity ≥ 80% rated capacity at 0℃.
Discharge Performance10-hour rate discharge capacity ≥ rated capacity; 30-minute rate discharge capacity ≥ 85% rated capacity.
Internal ResistanceInternal resistance of new batteries shall not exceed specified value; resistance deviation within the whole bank ≤ 5%.
Sealing PerformancePass air tightness test with no electrolyte leakage.
Environmental RequirementComplies with RoHS directive, no excessive heavy metals.

9.2 Bid Parameters for Battery Management System

Control ItemTechnical Requirements
Monitoring FunctionsMust support voltage, current, temperature, internal resistance, SOC and SOH monitoring.
CommunicationSupports RS485 (Modbus RTU) and Ethernet (Modbus TCP/IP).
Alarm FunctionsEquipped with audible & visual alarm, dry contact output and remote alarm.
Data StorageSupports historical data storage and export; storage period ≥ 1 year.
ExpandabilitySupports battery bank expansion and adapts to different capacity systems.
CompatibilityCompatible with mainstream UPS brands and connectable to environment monitoring systems.

9.3 Bid Parameters for System Integration

Control ItemTechnical Requirements
ConnectionCopper connecting components; cables comply with national standards; connection resistance within specified range.
ProtectionEquipped with overload, short circuit, overvoltage and overtemperature protection devices.
InstallationBattery cabinets/racks feature ventilation, heat dissipation, insulation and fireproof design.
TestingComplete factory test reports including capacity, internal resistance and safety tests shall be provided.
WarrantyMinimum 3-year warranty; free replacement for faulty batteries within warranty period.
ServiceProfessional installation guidance and regular maintenance services; 24-hour technical support.

X. Product Solutions

10.1 High-Reliability Solution for Data Centers

10.1.1 Solution Overview

To meet the ultra-high requirements on power reliability and stability of large data centers, this integrated solution combines KITOZER lead-acid batteries, online UPS and intelligent BMS to ensure 7×24 non-stop operation.

10.1.2 Solution Architecture

Dual Utility Input → ATS Switch → Redundant Online UPS → Power Distribution System → Server Cluster

                 ↑

                 │

                 └→ Dual Parallel KITOZER Battery Banks → BMS → Environment Monitoring Center

10.1.3 Solution Features

  1. Redundant architecture: Dual mains, dual UPS and dual battery banks eliminate single points of failure.
  2. Intelligent management: BMS monitors every single cell and gives early warnings of potential faults.
  3. Fast response: Battery instant discharge with switching time less than 2ms for imperceptible switching.
  4. Remote monitoring: Web-based remote management, real-time status view and automatic analysis reports.
  5. Hot swap: Batteries can be replaced without system shutdown during maintenance.
  6. Fire linkage: Automatically cuts off battery circuits once fire is detected for safety.

10.2 Cost-Effective Solution for Small & Medium Server Rooms

10.2.1 Solution Overview

Tailored for small & medium enterprise rooms and branch offices, this cost-efficient solution adopts KITOZER lead-acid batteries plus line-interactive UPS to guarantee basic power reliability while cutting investment costs.

10.2.2 Solution Architecture

Utility Input → Line-Interactive UPS → Load Devices

           ↑

           │

           └→ KITOZER Battery Bank → Basic BMS Monitoring Module

10.2.3 Solution Features

  1. Cost optimization: Line-interactive UPS with voltage regulation reduces battery cycling and extends service life.
  2. Compact layout: Standard rack-mounted batteries save room space.
  3. Basic monitoring: Simplified BMS monitors key parameters to ensure basic safety.
  4. Rapid deployment: Standard configuration for easy installation and shorter project cycle.
  5. Easy maintenance: Maintenance-free design lowers O&M costs for small and medium enterprises.

10.3 Integrated Solution for Edge Computing Nodes

10.3.1 Solution Overview

For outdoor or space-limited scenarios such as 5G base stations and edge computing nodes, this solution applies KITOZER gel lead-acid batteries and integrated UPS with high reliability and environmental adaptability.

10.3.2 Solution Features

  1. Extreme environment adaptability: Gel batteries work stably from -20℃ to 60℃.
  2. Integrated design: UPS and batteries are integrated into standard cabinets for space saving and easy deployment.
  3. Remote management: 4G/5G remote monitoring fits unattended sites.
  4. Low power consumption: Optimized charge-discharge strategy reduces energy use and extends battery life.
  5. High protection rating: IP54 protection for harsh outdoor environments.

XI. Application Cases

11.1 Case 1: Financial Data Center Project in Guangzhou

11.1.1 Project Background

This financial data center carries core banking systems and payment clearing services, requiring 99.9999% power availability. Any power cut will lead to huge economic losses and reputation risks.

11.1.2 Solution

Adopted KITOZER NP2-1000 2V/1000Ah VRLA batteries, two sets of 48-cell battery banks (total capacity 96000Ah) matched with K-BMS-64. Combined with two 200kVA online UPS to form a redundant power system.

11.1.3 Implementation Results

  • Realized zero-interruption power supply and ensured 7×24 continuous financial services.
  • BMS gave early warnings for 3 potential faults and prevented battery bank failure.
  • Batteries operate stably with capacity retention above 95%; actual service life has reached 8 years, exceeding expectation.
  • Obtained safety certification from the central bank and became a benchmark case in the financial industry.

11.2 Case 2: 5G Core Telecommunication Room Project in Shenzhen

11.2.1 Project Background

This 5G core room undertakes regional 5G network coverage. Continuous power supply for base station controllers and transmission equipment is required to keep network unblocked.

11.2.2 Solution

Adopted KITOZER NP12-150 12V/150Ah VRLA batteries, two sets of 16-cell banks equipped with K-BMS-32, forming a power system with two 100kVA online UPS.

11.2.3 Implementation Results

  • Successfully coped with 3 utility power outages and kept communication equipment running nonstop.
  • Remote monitoring via BMS; staff check battery status anytime via mobile APP.
  • Batteries work stably under room temperature up to 35℃ with capacity retention over 90%.
  • O&M costs reduced by 60%; battery replacement cycle extended to 8 years, highly recognized by the operator.

11.3 Case 3: Hospital ICU Project in Beijing

11.3.1 Project Background

The ICU is equipped with a large number of life-support devices including ventilators, ECG monitors and infusion pumps. Any power interruption will threaten patients’ lives, requiring extremely high power reliability.

11.3.2 Solution

Adopted KITOZER NP12-65 12V/65Ah VRLA batteries, two sets of 8-cell banks matched with K-BMS-16 and two 20kVA online UPS to build a redundant power system for ICU devices.

11.3.3 Implementation Results

  • Maintained normal operation during 5 grid fluctuations and 2 long-duration power cuts, protecting patients’ lives.
  • Precise battery monitoring by BMS keeps the battery bank in optimal condition all the time.
  • Maintenance-free design eases hospital O&M pressure; passed health authority safety certification.
  • Became a typical application case of UPS battery systems in the medical industry and promoted in multiple hospitals.

XII. SEO Keywords & Tags

12.1 Search Keywords

Server room lead-acid battery, KITOZER battery, UPS lead-acid battery, server room uninterruptible power supply, data center battery system, valve-regulated sealed lead-acid battery, battery management system, BMS system, server room battery solution, telecommunication room battery, lead-acid battery technical parameters, server room battery configuration list, lead-acid battery application cases, KITOZER brand battery, server room battery bid parameters

12.2 SEO Optimization Guidelines

  1. Core keyword layout: Distribute core keywords such as server room lead-acid battery and KITOZER battery reasonably across the full text to improve search engine ranking.
  2. Long-tail keywords: Adopt long-tail keywords including data center lead-acid battery solution and small & medium server room battery configuration to cover more search scenarios.
  3. Content structure: Use clear heading levels and lists for better crawling and understanding by search engines.
  4. Technical parameter enrichment: List detailed product parameters to enhance professionalism and search relevance.
  5. Authentic cases: Provide real application cases to improve content credibility and user stickiness.