Modular Cold & Hot Aisle System Solution (Aisle Fire Linkage Accessories)

I. System Introduction

1.1 System Overview

The KITOZER Modular Cold & Hot Aisle System (Aisle Fire Linkage Accessories) is an integrated intelligent airflow management and fire safety solution designed exclusively for critical infrastructures such as data centers and server rooms. By physically isolating cold and hot airflows combined with intelligent fire linkage control, the system achieves dual goals: maximizing cooling efficiency and optimizing fire safety. It provides a stable, secure and high-efficiency operating environment for IT equipment, reduces energy costs, and improves the overall PUE of the data center.

Core Values:

• 100% physical isolation of cold and hot airflows to eliminate air short-circuiting, raising cooling utilization to over 90%

• Seamless linkage with fire protection systems for automatic response in case of fire, safeguarding personnel and equipment

• Modular design enabling fast deployment and flexible expansion to fit data centers of all sizes

• Intelligent monitoring and remote management for real-time aisle status visibility and improved O&M efficiency

1.2 System Working Principle

The system adopts a dual mechanism of cold‑hot separation + intelligent linkage:

  1. Airflow Management: Racks are arranged face‑to‑face to form cold aisles and back‑to‑back to form hot aisles. Enclosed spaces are constructed with ceiling panels, side panels and end doors. Cold air is delivered into the cold aisle via raised floors or in‑row air conditioners, passes through rack perforated doors to absorb heat from IT equipment, and is exhausted into hot aisles for recycling by air conditioners, forming a high‑efficiency airflow cycle.
  2. Fire Linkage: When fire detectors (smoke/heat) detect anomalies, signals are sent to the fire linkage controller, which automatically triggers the following actions: ◦ Cut off non‑essential power supplies in the aisle ◦ Open fire‑fighting skylights (automatically open to 290° within 10 seconds) to ensure smooth entry of fire‑fighting gas ◦ Shut down ventilation equipment to prevent fire spread ◦ Activate audible and visual alarms to notify evacuation ◦ Link with gas fire suppression systems for precise agent discharge
(passageway fire alarm linkage accessories) system solution (1)

II. System Composition

The KITOZER Modular Cold & Hot Aisle System (Aisle Fire Linkage Accessories) consists of the following core components:

System ModuleMain ComponentsFunction Description
Basic Frame SystemAluminum alloy/steel aisle frames, columns, beamsSupports aisle structure; provides mounting base; load capacity ≥250kg/m²
Airflow Containment SystemAisle ceiling panels, side panels, end doors (manual/auto sliding)Physically isolates cold/hot air; air leakage rate ≤2%
Fire Linkage AccessoriesFire‑resistant transparent skylights (UL94 V0 polycarbonate), magnetic locks, linkage controllersAutomatically open skylights in fire events; cooperate with gas fire suppression systems
Intelligent Monitoring SystemTemperature & humidity sensors, smoke detectors, door contacts, audible‑visual alarmsReal‑time aisle environment monitoring; automatic alarm for anomalies
Control SystemAisle control module, fire linkage interface, remote management softwareLocal and remote control; seamless connection with fire systems
Auxiliary SystemLED lighting, emergency lighting, cable management trays, grounding devicesProvides illumination, cable management and safety grounding

III. System Classification

3.1 By Aisle Type

CategoryFeaturesApplicable Scenarios
Cold Aisle Containment SystemEncloses cold aisle for centralized cold air management; high cooling utilizationStandard data centers, high‑density rooms pursuing PUE optimization
Hot Aisle Containment SystemEncloses hot aisle for centralized hot air exhaust; improves AC efficiencyLegacy room retrofits, side‑supply AC scenarios
Dual Containment System (Cold + Hot)Encloses both aisles for maximum airflow efficiencyUltra‑high‑density data centers, large cloud computing centers

3.2 By Fire Linkage Mode

CategoryLinkage MechanismTrigger ConditionResponse Time
Electric Fire Linkage SystemDC24V signal trigger; magnetic lock de‑energizes; skylight opens automaticallyFire alarm signal, temperature ≥58°C≤10 seconds
Thermal Fuse Linkage SystemFuseLink automatic melting; skylight opens by gravityTemperature ≥58°C (independent of power)≤5 seconds
Dual‑Trigger Fire Linkage SystemElectric + thermal fuse dual trigger for extreme reliabilityFire signal OR over‑temperature≤3 seconds

3.3 By Deployment Scale

CategoryAisle LengthNumber of RacksApplicable Scenarios
Small Aisle System≤4m2–4 racksEdge computing nodes, small server rooms
Medium Aisle System4–10m4–10 racksEnterprise data centers, branch server rooms
Large Aisle System>10m>10 racksCloud computing centers, hyperscale data centers
(passageway fire alarm linkage accessories) system solution (2)

IV. System Configuration List (Brand: KITOZER)

4.1 Basic Frame Components

Product NameModelSpecificationsQuantityNotes
Aisle ColumnKT‑ZL‑120Height 2200/2400/2600mm; aluminum alloyCalculated by aisle lengthLoad ≥500kg per column
Aisle BeamKT‑HL‑80Length 600/800/1000mm; steel with powder coatingCalculated by aisle lengthFits standard rack spacing
Connecting BracketKT‑JJ‑01Aluminum alloy with matching boltsBy frame quantityReinforces frame connection

4.2 Airflow Containment Components

Product NameModelSpecificationsQuantityNotes
Aisle Ceiling PanelKT‑DB‑303mm polycarbonate sheet, UL94 V0Calculated by aisle areaLight transmittance ≥85%; UV‑resistant
Manual Sliding End DoorKT‑DM‑011200×2200mm; tempered glass + aluminum frame2 doors/aisleThreshold‑free for easy equipment access
Automatic Sliding End DoorKT‑DM‑021200×2200mm; tempered glass + aluminum frame; motor‑driven2 doors/aisleCard/induction opening; anti‑pinch function
Aisle Side PanelKT‑CB‑01Aluminum alloy; height 2200mmCalculated by aisle lengthRemovable for maintenance

4.3 Fire Linkage Accessories (Core Components)

Product NameModelSpecificationsQuantityNotes
Fire‑Resistant Transparent SkylightKT‑XC‑303mm fire‑retardant polycarbonate, UL94 V0Calculated by aisle areaOpens to 290° within 10s; load ≥250kg/m²
Magnetic LockKT‑CL‑24DC24V; holding force ≥200kg1 per skylightFire linkage control; power‑off release
Linkage ControllerKT‑LD‑018‑channel I/O; DC24V power supply1 per aisleConnects to fire system; dry contact support
Smoke DetectorKT‑YW‑01Photoelectric; sensitivity 0.05–0.15%obs/m1 per 10㎡Links with linkage controller
Heat DetectorKT‑WG‑01Temp range ‑10~80°C; response at 58°C1 per 10㎡Dual protection against false alarms
Audible‑Visual AlarmKT‑SG‑01Volume ≥85dB; flash frequency 1–2Hz1 per aisleAudible‑visual alert in fire event

4.4 Intelligent Monitoring & Control System

Product NameModelSpecificationsQuantityNotes
Aisle Control ModuleKT‑KZ‑01Integrates temp/humidity monitoring, door status, skylight control1 per aisleLocal control and display
Fire Linkage InterfaceKT‑JK‑01Standard RS485; Modbus protocol1 per aisleConnects to third‑party fire systems
Remote Management SoftwareKT‑RM‑01Web access; real‑time monitoring and control1 set per projectCentralized multi‑aisle management; historical data query
Door Contact SwitchKT‑MC‑01Normally open/closed optional2 per aisleMonitors end door status; anomaly alarm

4.5 Auxiliary Components

Product NameModelSpecificationsQuantityNotes
LED LightingKT‑ZM‑01DC24V; 13W; 90cm lengthCalculated by aisle lengthEnergy‑saving; lifespan ≥50000 hours
Emergency LightingKT‑YJ‑01DC12V; built‑in battery; ≥90 minutes duration2 per aisleAuto‑activates on power failure
Cable Management TrayKT‑XL‑01Width 150mm; height 100mmCalculated by aisle lengthSeparation of strong/weak current; supports 10G/400G
Grounding DeviceKT‑JD‑01Copper; grounding resistance ≤1Ω4 per aisleEnsures personnel and equipment safety
(passageway fire alarm linkage accessories) system solution (3)

V. System Schematic Diagrams

5.1 Airflow Cycle Diagram

[Raised Floor/In‑Row AC] → [Cold Air] → [Enclosed Cold Aisle] → [Rack Perforated Door] → [IT Equipment (Heat Absorption)] → [Hot Aisle] → [AC Return Air] → [AC Treatment] → [Cold Air]

5.2 Fire Linkage Control Diagram

[Fire Detector (Smoke/Heat)] → [Fire Controller] → [Linkage Signal] → [KT‑LD‑01 Linkage Controller] → [Action Execution]
├─ Cut non‑essential power
├─ Magnetic lock de‑energized → Fire skylight open (within 10s)
├─ Shut down ventilation equipment
├─ Activate audible‑visual alarm
└─ Link gas fire suppression system

5.3 System Topology Diagram

[Data Center Monitoring Center] ↔ [KT‑RM‑01 Remote Management Software] ↔ [KT‑LD‑01 Linkage Controller] ↔ [Sensors/Actuators]
↓
[Fire Control System] ↔ [Linkage Interface]

VI. Product Technical Specifications

6.1 Basic Frame Specifications

ItemTechnical IndexTest Standard
Frame MaterialAluminum alloy 6063‑T5 / high‑grade steelGB/T 5237.1‑2017
Surface TreatmentAnodizing / electrostatic powder coatingGB/T 18593‑2010
Load Capacity≥250kg/m²GB 28007‑2011
Dimensional Accuracy±1mmGB/T 1804‑2000
Service Life≥15 yearsIndustry standard

6.2 Airflow Containment Components Specifications

ItemTechnical IndexTest Standard
Air Leakage Rate≤2%GB/T 1236‑2017
Light Transmittance≥85% (ceiling/skylight)GB/T 2680‑1994
End Door OpeningManual/auto sliding; opening force ≤50NGB 28007‑2011
Fire RatingCeiling/skylight UL94 V0UL 94
Weather ResistanceUV‑resistant; lifespan ≥10 yearsGB/T 16422.2‑2014

6.3 Fire Linkage Accessories Core Specifications

ItemTechnical IndexTest Standard
Skylight Opening Time≤10 secondsGB 50116‑2013
Skylight Opening Angle290°Enterprise Standard
Magnetic Lock VoltageDC24V; power ≤5WGB/T 156‑2017
Detector Response Time≤3 secondsGB 4715‑2005
Linkage Controller InterfaceDry contact; supports ModbusGB/T 19582‑2008
Operating Temperature‑10°C~+55°CGB/T 2423.1‑2008
Relative Humidity10%~90% (non‑condensing)GB/T 2423.3‑2006

6.4 Intelligent Monitoring System Specifications

ItemTechnical IndexTest Standard
Temp Monitoring Range‑10°C~+80°C; accuracy ±0.5°CGB/T 15479‑1995
Humidity Monitoring Range0%~100%RH; accuracy ±3%RHGB/T 15481‑2017
CommunicationRS485, EthernetGB/T 19582‑2008
Data Refresh Rate≤1 secondEnterprise Standard
Alarm ModeAudible‑visual; remote notificationGB 4717‑2005
(passageway fire alarm linkage accessories) system solution (4)

VII. Application Scope

The KITOZER Modular Cold & Hot Aisle System (Aisle Fire Linkage Accessories) is suitable for:

7.1 Data Center Sector

• New large‑scale data centers and cloud computing centers

• Upgrade and retrofitting of existing data centers to improve cooling efficiency

• High‑density server rooms resolving local hotspots

• Edge computing nodes and small server rooms

• Financial, telecom, Internet and other mission‑critical data centers

7.2 Other Fields

• Telecommunication rooms and core equipment rooms

• Industrial automation control centers

• Medical imaging storage centers and scientific computing centers

• Military command centers and aerospace control centers

• Precision instrument laboratories sensitive to temperature

(passageway fire alarm linkage accessories) system solution (5)

VIII. Product Advantages

8.1 Performance Advantages

  1. High Efficiency & Energy Saving: Isolates cold/hot airflows; cooling utilization >90%; reduces PUE below 1.3
  2. Precise Temperature Control: Aisle temperature stable at 18–22°C; zone temperature difference ≤1°C; no local hotspots (≤24°C)
  3. Fast Response: Fire linkage response ≤10 seconds for timely fire handling
  4. High Reliability: Key components use UL94 V0 fire‑retardant materials for extreme safety

8.2 Design Advantages

  1. Modular Design: Factory‑prefabricated components; on‑site fast assembly; deployment time reduced by 50%
  2. Flexible Expansion: Adjustable aisle length/width to fit various room sizes
  3. User‑Friendly: Threshold‑free doors for equipment access; removable side panels for easy maintenance
  4. Aesthetic Design: Transparent ceiling and glass doors enhance room appearance

8.3 Safety Advantages

  1. Dual Fire Protection: Electric + thermal fuse dual trigger; works even under power failure
  2. Personnel Safety: Emergency lighting, grounding, anti‑pinch doors for full protection
  3. Equipment Safety: Links with clean gas fire suppression; no damage to electronics
  4. Compliance: Meets GB 50174‑2017 Code for Design of Data Centers, GB 50016‑2014 Code of Design on Building Fire Protection and Prevention, etc.

8.4 O&M Advantages

  1. Intelligent Monitoring: Real‑time status; automatic anomaly alarm; remote management
  2. Easy Maintenance: Modular components for quick replacement; lower maintenance cost
  3. Historical Data Analysis: Logs temp, humidity, alarms for O&M optimization
  4. Remote Diagnosis: Remote fault troubleshooting reduces on‑site visits
(passageway fire alarm linkage accessories) system solution (6)

IX. Bid‑Winning Parameters

9.1 Core Technical Parameters (Key Bid Points)

  1. Aisle frame: Aluminum alloy 6063‑T5; load ≥250kg/m²; compliant with GB/T 5237.1‑2017
  2. Fire skylight: 3mm fire‑retardant polycarbonate; UL94 V0; opens to 290° within 10s; compliant with UL 94
  3. Linkage response time: ≤10 seconds (including skylight opening, power cut, etc.)
  4. Air leakage rate: Overall aisle leakage ≤2%; compliant with GB/T 1236‑2017
  5. Temperature control accuracy: Aisle temp 18–22°C; zone difference ≤1°C; compliant with GB 50174‑2017
  6. Communication protocol: Supports Modbus; seamless third‑party monitoring integration; compliant with GB/T 19582‑2008
  7. Fire rating: Key components ≥ UL94 V0; compliant with UL 94
  8. Service life: Core components ≥10 years; meets industry standards

9.2 Commercial Parameters (Key Bid Points)

  1. Brand Qualification: KITOZER original factory production; provide brand authorization
  2. Certification: ISO9001 quality system, ISO14001 environmental certification required
  3. After‑Sales: ≥5‑year warranty; 24‑hour response; 48‑hour on‑site service
  4. References: ≥3 successful similar projects with user testimonials
  5. Technical Support: One‑stop service including design, installation guidance, commissioning and training

X. Customized Solutions

10.1 New Data Center Solution

  1. Demand Analysis: Design aisle layout based on room size, rack count and power density
  2. Solution Design: Cold aisle containment + fire linkage with in‑row AC for precise cooling
  3. Product Configuration: Full KITOZER modular aisle + fire linkage + intelligent monitoring
  4. Implementation Steps: ◦ Room planning and design ◦ Frame installation → Containment installation → Fire linkage installation → Monitoring installation ◦ System commissioning → Fire linkage test → User training
  5. Expected Outcome: PUE <1.3; cooling efficiency +30%; highest fire safety level

10.2 Existing Data Center Retrofit Solution

  1. Status Assessment: Analyze current airflow, cooling efficiency and fire system
  2. Solution Design: Partial cold aisle containment + fire linkage upgrade with minimal disruption
  3. Product Configuration: Aisle components matching existing racks + fire linkage + monitoring
  4. Implementation Steps: ◦ Zone‑by‑zone retrofit without business interruption ◦ Night construction to reduce impact ◦ Post‑retrofit testing for stable operation
  5. Expected Outcome: Cooling efficiency +20%; PUE reduced by 0.2–0.3; intelligent fire linkage

10.3 High‑Density Server Room Solution (≥8kW/rack)

  1. Demand Analysis: Resolve local hotspots for high‑power density rooms
  2. Solution Design: Dual cold/hot aisle containment + in‑row AC + intelligent fire linkage for maximum cooling
  3. Product Configuration: Reinforced frame + high‑efficiency containment + dual‑trigger fire linkage + high‑precision monitoring
  4. Implementation Steps: ◦ Pre‑simulation airflow analysis to optimize layout ◦ Custom component production for high‑density racks ◦ Installation and commissioning with focus on fire linkage
  5. Expected Outcome: Aisle temp stable at 20±1°C; no hotspots; fire response ≤5 seconds

XI. Application Cases

11.1 Case 1: Cloud Computing Center of a Large Internet Enterprise

• Project Profile: 1000 racks; 6kW/rack; new data center

• Solution: KITOZER cold aisle containment + fire linkage + intelligent monitoring with in‑row AC

• Results:

◦ PUE reduced from 1.8 to 1.28; annual electricity cost saving ~RMB 8 million

◦ Fire linkage response ≤8 seconds; passed fire inspection

◦ Stable operation for 2 years with zero failures

• User Comment: “The KITOZER system not only improves cooling efficiency but also provides all‑around fire safety for our data center.”

11.2 Case 2: Data Center Retrofit for a Financial Institution

• Project Profile: 500 racks; 4kW/rack; existing data center upgrade

• Solution: Partial cold aisle containment + fire linkage upgrade with minimal business impact

• Results:

◦ Cooling efficiency +25%; PUE from 1.6 to 1.35

◦ Zero business disruption during retrofit

◦ Fire system upgraded to intelligent linkage; meets latest codes

• User Comment: “The retrofit perfectly solves our pain points, improving efficiency and safety without business interruption.”

11.3 Case 3: Supercomputing Center of a Research Institute

• Project Profile: 200 racks; 10kW/rack; high‑density room

• Solution: Dual cold/hot aisle containment + dual‑trigger fire linkage + high‑precision monitoring

• Results:

◦ Aisle temp stable at 20±0.5°C; no local hotspots

◦ Fire linkage response ≤5 seconds; dual‑trigger ensures safety

◦ Cooling efficiency +35%; meets supercomputing requirements

• User Comment: “KITOZER provides a stable environment for our supercomputing equipment with full fire safety protection.”

XII. Search Keywords, SEO & Tags

12.1 Core Search Keywords

• Modular Cold & Hot Aisle

• Aisle Fire Linkage Accessories

• KITOZER Cold & Hot Aisle

• Data Center Cold Aisle

• Server Room Fire Linkage System

• Cold & Hot Aisle Containment System

• Intelligent Cold & Hot Aisle

• Data Center PUE Optimization

• Fire Skylight Linkage System

• Modular Server Room Solution

12.2 SEO Keywords

• Modular Cold & Hot Aisle System Solution

• Data Center Cold & Hot Aisle Fire Linkage Accessories

• KITOZER Cold Aisle Fire Linkage System

• New Data Center Cold Aisle Design

• Existing Data Center Cold Aisle Retrofit

• High‑Density Room Cold & Hot Aisle Solution

• Data Center Fire Linkage Control System

• Cold Aisle Containment Working Principle

• Cold & Hot Aisle System Technical Specifications

• Data Center Airflow Management Solution

12.3 Tags

#ModularColdHotAisle #FireLinkageAccessories #KITOZER #DataCenter #ServerRoom #ColdAisleContainment #HotAisleContainment #FireSkylight #IntelligentMonitoring #PUEOptimization #AirflowManagement #FireSafety #DataCenterSolution #ServerRoomRetrofit

Shopping Cart