Table of Contents
Toggle1. Cover / Document Information
– Document Title: Motor Noise Semi-Automatic Test System (Shell-Type Pneumatic Shielding Box) Technical Design Solution
– Prepared by: Guangzhou Lain Intelligent System Development Co., Ltd.
– Brand: KITOZER (Pioneer)
– Date: August 2026
– Version: V1.0
– Project Type: Technical design solution for Motor Noise Semi-Automatic Test System (Shell-Type Pneumatic Shielding Box)
2. Table of Contents Structure
1. Company Introduction
2. Project Overview
3. User Requirement Analysis
4. Overall Design Description
5. Detailed System Design and Product Technical Parameters
6. Project Quotation and Configuration List
7. Core Solution Advantages
8. Technical Q&A
9. Construction Schedule Plan
10. Construction Organization Plan
11. After-Sales Service System
12. Operation and Maintenance Training Plan
13. Typical Project Cases
14. SEO Optimization System and Website Backend Configuration
15. Contact Information
3. Company Introduction
3.1 Company Development Overview
Founded in 2002, Guangzhou Lain Intelligent System Development Co., Ltd. is a high-tech enterprise dedicated to the computer room construction and intelligent protection field for more than two decades, integrating R&D, production, sales, engineering implementation and after-sales service. The company focuses on innovative breakthroughs in electromagnetic shielding technology, modular computer room technology and computer room environmental monitoring technology, and has grown into a source manufacturer with core competitiveness in the domestic computer room construction field.
After more than twenty years of industry accumulation, the company has built a large-scale production and manufacturing base equipped with advanced CNC sheet metal processing equipment, automated spraying production lines and professional testing laboratories, with an annual production capacity of hundreds of sets of shielding computer rooms, integrated cabinets and micro-module products. The company’s service network covers all provinces and cities across the country, providing thousands of computer room construction and renovation services for customers in government, military, scientific research, finance and enterprise fields.
3.2 Core Business System
The company’s core business revolves around the full-lifecycle construction of computer rooms, forming four major product and service systems:
– Computer room EPC general contracting service: one-stop services from solution design, manufacturing, on-site construction to commissioning and acceptance, covering shielding computer rooms, IDC data rooms, modular computer rooms, container computer rooms and other types;
– Core equipment R&D and production: independently produces KITOZER brand series products, including shielding cabinets, shielding desks, consoles, integrated data cabinets, micro-module cold aisle cabinets, outdoor rainproof cabinets, etc., supporting non-standard customization;
– Computer room environmental monitoring system: provides full-element monitoring solutions for temperature and humidity, water leakage, access control, video, fire protection, UPS and power distribution, realizing intelligent and unattended O&M;
– Shielding and security protection products: shielding rooms, shielding doors and windows, anechoic chambers and related auxiliary materials, widely used in confidential, military and scientific research fields.
3.3 Brand and Qualification Honors
The core brand KITOZER (Pioneer) focuses on computer room equipment and shielding products, positioned as an “efficient, green, innovative and safe” solution provider. Products have passed multiple authoritative tests and comply with national and industry standards. The company holds multiple utility model patents and software copyrights, has been awarded high-tech enterprise qualification, and follows the ISO9001 quality management standard.
3.4 Core Competitive Advantages
1. Source production, controllable quality: own production base and professional processing equipment; core products independently produced with full-process quality control, providing more cost-effective solutions without intermediate links;
2. Customized design, matching needs: tailor-made solutions per site conditions, technical requirements, configuration and budget, with multiple design options provided free of charge;
3. Professional team, rich experience: a professional technical team of engineers and project managers with more than ten years of industry experience;
4. Quality after-sales, full guarantee: a 7×24 professional online service system with dedicated project follow-up from early coordination to later O&M.
4. Project Background and Objectives
4.1 Industry Background and Pain Points
Motors are core power components in appliances, automotive, new energy, industrial automation and aerospace; their noise level is a key quality indicator. Traditional motor noise testing relies on professional anechoic chambers: high construction cost (hundreds of thousands to millions), low efficiency (manual transport into the chamber, incompatible with production lines), poor site flexibility (fixed building) and high O&M cost. Ordinary workshop background noise makes direct testing inaccurate. A compact noise test system deployable on the workshop floor with high accuracy and automation is an urgent industry need.
4.2 Project Objectives
This project provides the semi-automatic motor noise test system (shell-type pneumatic shielding box): directly deployable in ordinary workshops without an anechoic room, supporting semi-automatic unattended testing:
– Scenario adaptation: effective background noise isolation approaching anechoic-room accuracy;
– Efficiency: pneumatic auto open/close and dual-head manipulator tooling, short test cycle matching line rhythm;
– Intelligent automation: professional software for auto acquisition, analysis, judgment, storage and report export; unattended operation;
– Flexibility: modular design with quick-change fixtures for multiple motor models; single-unit or production-line semi-automation;
– Cost performance: 1/5~1/10 the investment of anechoic chambers, small footprint, short payback.
4.3 Solution Value
Reduced detection cost (no anechoic chamber); improved production efficiency 30%+ (line-side deployment, matched rhythm); guaranteed quality (high-accuracy auto judgment, full-batch control); labor savings (unattended, one operator for multiple units); traceable data (auto archiving for quality tracing and big-data analysis).
5. User Requirement Analysis
5.1 Core Functional Requirements
– Workshop on-site acoustic testing without anechoic room — closed box isolates background noise;
– Shell-type pneumatic shielding box: automatic open/close, compact, sealed without acoustic leakage;
– Dual-head linear manipulator: X/Z axis automatic positioning, dual-point simultaneous and multi-point scanning tests with configurable coordinates;
– Customized motor fixtures: precise positioning, quick clamping, vibration-damping, quick change for multiple models;
– Dual software: tooling action control software + unattended test software (acquisition, spectrum analysis, judgment, data management, report export);
– Complete accessories: acoustic coupling plates, signal attenuation plates, wiring harnesses, industrial PC, monitor/keyboard — plug-and-play after power and air connection.
5.2 Performance Requirements
– Acoustic: frequency 20Hz-20kHz; SPL 30-120dB(A); accuracy ≤±1dB, repeatability ≤±0.5dB; box sound insulation ≥30dB mid/high frequency;
– Mechanical: manipulator positioning ±0.1mm; fixture repeatability ±0.05mm; box open/close 2-3s adjustable; MTBF ≥10,000h;
– Efficiency: full test cycle ≤30s per product; 24h continuous operation for three-shift production.
5.3 Automation and Integration
– Single-unit semi-automatic mode: manual loading, two-hand start, automatic test flow (sampling, R&D);
– Production-line linkage mode: standard IO + Modbus/TCP/IP interfaces for automatic trigger and pass/fail output;
– Unattended operation: automatic test cycles, auto alarm and log on faults.
5.4 Environment and Safety
– 0-45℃, 30-85%RH industrial environment; dust and vibration resistance;
– Safety light curtain, two-hand start, emergency stop, safety relay — per industrial safety standards;
– Overload, leakage and short-circuit protection per electrical safety codes.
6. Design Principles and Applicable Standards
6.1 Design Principles
1. Reliability first: industrial-grade branded components, fatigue-verified mechanics, extensively tested control programs;
2. Test accuracy: professional acoustic components, simulated acoustic structure, complete vibration isolation — data accuracy and repeatability;
3. Intrinsic safety: multi-layer safety interlocks at mechanical, electrical and software levels;
4. Ease of use: intuitive interface, modular parameters, quick fixture change, short training;
5. Expandable: reserved space for new stations, function upgrades and MES/ERP integration.
7. System Architecture and Working Principle
7.1 Overall System Architecture
Six subsystems: shielded acoustic box (sealed test space isolating noise/EMI); mechanical tooling (dual-head manipulator, fixtures, frame, vibration isolation); pneumatic drive (clean stable power for open/close and clamping); acoustic acquisition (microphones, coupling plates, attenuation plates, conditioning, acquisition card); electrical control (PLC with safety modules); software and data (lower-machine control + upper-machine test software).
7.2 Working Principle
Manual single-unit mode: standby self-check → product clamping in fixture → two-hand start with light-curtain check → box closes (pneumatic, sealed) → manipulator positions microphones → motor starts → acquisition → analysis (time/frequency domain, SPL, band values vs thresholds) → judgment → open/reset → data stored.
Automatic line mode: line conveys product to station → sensor triggers → auto clamping → box closes → same auto test flow → pass/fail signal to line → product flows out (defective rejected) → waits for next; anomalies stop the system with alarm and log.
7.3 Shielded Acoustic Box Design
Shell-type flip-top structure; quality cold-rolled steel welded with polished seams; four-layer composite sound insulation (steel plate – damping layer – insulation layer – absorption layer): outer steel for structure and air-borne isolation, butyl rubber damping suppressing resonance, inner galvanized steel increasing insulation, innermost pyramidal acoustic foam absorbing reflections (no standing waves/reverberation, near free-field). Full-perimeter foam silicone sealing strip compressed by pneumatic clamping — no gap leakage; replaceable strip. Four adjustable heavy support feet; side handles; embedded front panel.
7.4 Mechanical Tooling Design
Dual-head linear manipulator: independent X (horizontal) and Z (vertical) axes, ball-screw + linear guide drives, stepper motors with subdivision drivers, ±0.1mm positioning. Universal probe holders compatible with 1/2″ and 1/4″ microphones, 360° rotation and tilt adjustment. Fixture base: 20mm anti-static bakelite plate with locating holes and T-slots; four spring-rubber composite damping columns attenuating floor vibration. Customized motor fixtures: profile cavity positioning with quick clamps and locating pins; bakelite/aluminum base.
7.5 Acoustic Acquisition, Pneumatic, Electrical and Software Design
Acoustic: professional measurement microphones, coupling/attenuation plates, signal conditioning (ICP), data acquisition card (multi-channel, high sample rate); Pneumatic: air treatment (filter/regulator), solenoid valves, cylinders for box and clamping with magnetic switches; Electrical: PLC control with safety relay, light curtain interface, two-hand start, emergency stop; Software: lower-machine control (motion logic, parameters, status) and upper-machine test software (acquisition, FFT analysis, thresholds, judgment, database, report export).
8. Detailed Technical Design
8.1 Shell-Type Pneumatic Acoustic Shielding Box
– Flip-top shell structure; cold-rolled steel welded, polished seams; acid-wash/phosphating/electrostatic powder coating;
– Four-layer composite insulation (steel – butyl damping – galvanized steel – pyramidal acoustic foam), mid/high insulation ≥30dB;
– Full-perimeter foam silicone sealing strip, pneumatic compression, replaceable; adjustable heavy support feet; side handles; embedded front panel with buttons/indicators.
8.2 Dual-Head Linear Manipulator Module
– Dual independent axes (X horizontal, Z vertical), ball-screw + linear guide, stepper motors with subdivision drivers, positioning ±0.1mm;
– Universal probe holders (1/2″ and 1/4″ microphones), 360° rotation, tilt adjustment;
– Dual-point simultaneous and multi-point scanning tests with configurable coordinates.
8.3 Pneumatic System
– Air treatment (filter, regulator, lubricator as needed), solenoid valves, cylinders for box open/close and fixture clamping, magnetic switches for position feedback; supply 0.4-0.7MPa clean compressed air; open/close 2-3s adjustable.
8.4 Acoustic Acquisition System
– Professional measurement microphones (frequency 20Hz-20kHz, SPL 30-120dB(A));
– Signal conditioning module (ICP), data acquisition card (multi-channel, high sample rate);
– Acoustic coupling plates and signal attenuation plates included;
– Accuracy ≤±1dB, repeatability ≤±0.5dB.
8.5 Electrical Control System
– PLC core control with safety relay, light curtain interface, two-hand start, emergency stop;
– Overload, leakage and short-circuit protection; industrial-grade wiring with labels;
– Standard IO and Modbus/TCP/IP interfaces for line integration.
8.6 Software System
– Lower-machine control software: motion logic, parameter settings, status monitoring;
– Upper-machine test software: acquisition, time/frequency analysis, band SPL, threshold judgment, database storage, report export; unattended auto cycles with alarms and logs.
8.7 Industrial PC
– Industrial-grade PC with monitor/keyboard; runs test software; local database for traceability.
9. Recommended Configuration and Preliminary Budget
9.1 Configuration List
| No. | Item | Specification | Unit | Qty |
|---|---|---|---|---|
| 1 | Shell-type pneumatic shielding box | Flip-top, four-layer insulation, ≥30dB, pneumatic close | set | 1 |
| 2 | Dual-head linear manipulator | X/Z axes, ±0.1mm, dual probe holders | set | 1 |
| 3 | Pneumatic system | Air treatment, valves, cylinders, switches | set | 1 |
| 4 | Acoustic acquisition system | Microphones, conditioning, DAQ card, coupling/attenuation plates | set | 1 |
| 5 | Electrical control system | PLC, safety module, light curtain, two-hand start, E-stop | set | 1 |
| 6 | Software (dual) | Control software + test software with license | set | 1 |
| 7 | Industrial PC + monitor/keyboard | Per spec | set | 1 |
| 8 | Customized motor fixtures | Per product drawings, vibration-damping | set | per model |
| 9 | Wiring harnesses and accessories | Full set | lot | 1 |
9.2 Quotation Notes
The list covers the complete semi-automatic motor noise test system; fixture quantities per product models. The quotation includes equipment, software, installation, commissioning, training and warranty; transport and tax itemized. All reference prices in this solution are in RMB (CNY) only and are for reference purposes; a formal quotation is issued after configuration confirmation.
10. Technical Specifications
10.1 System Performance Summary
| Item | Specification |
|---|---|
| Test frequency | 20Hz-20kHz |
| SPL range | 30-120dB(A) |
| Accuracy | ≤±1dB; repeatability ≤±0.5dB |
| Box insulation | ≥30dB mid/high frequency |
| Manipulator positioning | ±0.1mm; fixture repeatability ±0.05mm |
| Box open/close | 2-3s adjustable |
| Test cycle | ≤30s per product |
| MTBF | ≥10,000h |
| Operation | Manual single-unit + automatic line modes; unattended |
| Communication | IO + Modbus/TCP/IP |
| Safety | Light curtain, two-hand start, E-stop, safety relay |
| Environment | 0-45℃, 30-85%RH |
| Power/Air | AC220V; 0.4-0.7MPa compressed air |
10.2 Key Component Specifications
| Component | Key Parameters |
|---|---|
| Acoustic box | Four-layer insulation, pneumatic sealed |
| Manipulator | Ball-screw + linear guide, stepper drives |
| Microphone | 1/2″ or 1/4″, professional measurement |
| DAQ card | Multi-channel, high sample rate |
| PLC | Safety relay, light curtain, IO/Modbus/TCP |
11. Key Advantages and Customer Value
11.1 No Anechoic Room Needed
Four-layer acoustic insulation (≥30dB) isolates workshop background noise — near-anechoic accuracy at 1/5~1/10 the investment, flexible deployment.
11.2 Semi-Automatic High Efficiency
Pneumatic auto open/close, dual-head manipulator positioning and automatic test flow — ≤30s per product, 30%+ production efficiency improvement, matching line rhythm.
11.3 Dual-Probe Synchronous Testing
Two microphones with X/Z positioning support dual-point simultaneous and multi-point scanning — comprehensive, high-accuracy data.
11.4 Multi-Layer Safety Protection
Light curtain, two-hand start, emergency stop and safety relay — operator safety assured per industrial standards.
11.5 Modular Customization
Quick-change fixtures for multiple motor models; manual or line modes; expandable for new stations, functions and MES/ERP integration.
11.6 Full-Process Service
Survey, design, production, installation, commissioning, training and after-sales with 7×24 support — worry-free operation.
12. Technical Q&A (50+ Items)
12.1 Equipment Basics
Q1: What is this test system?
A: A semi-automatic motor noise test system with a shell-type pneumatic shielding box: deployed on the workshop floor, it isolates background noise and automatically measures motor noise without an anechoic room.
Q2: How does it achieve anechoic-room accuracy?
A: Four-layer composite insulation (≥30dB) blocks background noise; pyramid foam absorbs internal reflections creating a near free-field; vibration-damping tooling isolates floor vibration.
Q3: Why pneumatic open/close?
A: Pneumatic actuation provides fast (2-3s), repeatable, force-controlled sealing — consistent acoustic conditions and automation without manual effort.
Q4: What motors can it test?
A: Customized fixtures adapt to the customer’s motor models; quick-change fixtures support multiple models.
Q5: Is an anechoic room still needed?
A: No — the system replaces it for production-line noise testing; consult for applications requiring formal standardized chamber certification.
12.2 Acoustic Performance
Q6: What frequency range is covered?
A: 20Hz-20kHz — the full motor noise band.
Q7: What is the accuracy?
A: ≤±1dB measurement error and ≤±0.5dB repeatability — meeting quality control requirements.
Q8: How is background noise isolated?
A: The closed box with full-perimeter sealed strip and four-layer insulation provides ≥30dB mid/high-frequency isolation.
Q9: How is measurement repeatability ensured?
A: Fixed probe positioning (±0.1mm), consistent box sealing, vibration isolation and calibrated acquisition chain.
Q10: How are results analyzed?
A: Time/frequency domain analysis: overall SPL and characteristic band values compared with thresholds for automatic pass/fail judgment.
Q11: What is the SPL measurement range?
A: 30-120dB(A) — covering motor noise levels.
Q12: Can spectrum analysis be performed?
A: Yes — FFT analysis with band values, curves and reports.
12.3 Automation and Functions
Q13: What operating modes exist?
A: Manual single-unit (sampling/R&D) and automatic line modes (production integration) with unattended auto cycles.
Q14: How does the manual mode work?
A: Load product → two-hand start (light curtain check) → box closes → probes position → motor runs → acquisition → judgment → open/reset → data stored.
Q15: How does the line mode work?
A: Line conveys product → sensor triggers → auto clamp → box closes → auto test → pass/fail signal → product flows out; defective rejected; waits for next.
Q16: Can it integrate with production lines?
A: Yes — standard IO and Modbus/TCP/IP interfaces for triggering and result output.
Q17: How long is the test cycle?
A: ≤30s per product including clamping, box open/close, test and judgment.
Q18: Can it run unattended?
A: Yes — automatic cycles with alarms and logs on faults; one operator can manage multiple units.
Q19: How are probes positioned?
A: The dual-head manipulator moves microphones to configurable X/Z coordinates — dual-point simultaneous or multi-point scanning.
Q20: What if a product is mispositioned?
A: The system stops with alarm and logs the anomaly; light curtain and clamping feedback prevent unsafe operation.
12.4 Installation and Maintenance
Q21: What utilities are needed?
A: AC220V power and 0.4-0.7MPa clean compressed air — plug-and-play.
Q22: How is the system installed?
A: Position and level with adjustable feet, connect power/air, install fixtures, load software, calibrate probes, commission — typically 1-2 days.
Q23: How are fixtures changed?
A: Quick-release clamping on the T-slot base — minutes per change for different models.
Q24: What daily maintenance is needed?
A: Air filter drain, sealing strip inspection, probe calibration check, cleaning — per the manual schedule.
Q25: How are microphones calibrated?
A: With a standard sound calibrator per the schedule; calibration records maintained.
Q26: What spares are recommended?
A: Sealing strips, microphones, pneumatic components, sensors and fuses — stocked for fast replacement.
Q27: What is the MTBF?
A: ≥10,000h with industrial-grade components and routine maintenance.
Q28: What is the warranty?
A: Typically 1-2 years with free repair of non-artificial faults; lifetime cost-price maintenance after warranty.
12.5 Selection and Customization
Q29: Can the system test other products?
A: Yes — fixtures and probe layouts can be adapted for other noise-test products (pumps, fans, gearboxes).
Q30: Can more test stations be added?
A: Yes — modular design supports adding stations and expanding the system.
Q31: Can it integrate with MES/ERP?
A: Yes — data interfaces support MES/ERP integration for quality traceability.
Q32: What software is included?
A: Lower-machine control software and upper-machine test software with data management and report export.
Q33: Can the box size be customized?
A: Yes — box dimensions adapt to the product size range; consult for large products.
Q34: What is the delivery time?
A: Typically 20-35 working days for a standard system (design + production + commissioning); fixtures per drawings.
Q35: What training is provided?
A: Operation, fixture change, maintenance and software training with materials and repeat sessions.
Q36: What documentation is delivered?
A: Manuals, wiring diagrams, pneumatic diagrams, calibration records, certificates and after-sales card.
Q37: What is the response time?
A: 7×24 support; remote within 1 hour; on-site per region; urgent faults prioritized.
Q38: Is on-site commissioning included?
A: Yes — engineers commission the system on site with calibration and acceptance.
Q39: How is acceptance performed?
A: Test accuracy/repeatability verification, function tests (modes, safety, communication) and documentation — jointly signed.
Q40: What are the total costs?
A: Equipment + fixtures + software + installation/commissioning + training + transport/tax; final quotation after configuration.
12.6 Additional Questions
Q41: Is the system safe to operate?
A: Yes — light curtain, two-hand start, emergency stop and safety relay per industrial safety standards.
Q42: Can it run 24h?
A: Yes — designed for three-shift continuous operation.
Q43: What is the noise of the system itself?
A: Low — pneumatic and stepper actuation are quiet; the system’s own noise does not affect measurements inside the closed box.
Q44: How is data stored?
A: Local database with test time, operator and results; exportable for tracing and analysis.
Q45: Can thresholds be adjusted?
A: Yes — pass/fail thresholds per frequency band configurable in the software per product requirements.
Q46: What if the air supply fails?
A: The system detects insufficient pressure and alarms/stops safely; box remains closed until pressure restored per sequence.
Q47: Does the box require acoustic foam maintenance?
A: Pyramid foam is durable; periodic inspection and cleaning per the manual; replacement available.
Q48: Can the system be moved between sites?
A: Yes — compact with handles and adjustable feet; re-installation and calibration quick.
Q49: Is electromagnetic shielding provided?
A: The steel box provides inherent EMI shielding for stable acquisition; consult for stringent EMC requirements.
Q50: How does it improve quality control?
A: Full-batch auto testing with accurate judgment eliminates manual misjudgment and defective outflow.
Q51: What is the payback period?
A: Typically short — equipment cost is 1/5~1/10 of an anechoic chamber with labor and efficiency savings.
Q52: How is the project started?
A: Product and site survey → design confirmation → contract → production → installation/commissioning → training → acceptance; dedicated project manager.
13. Construction Schedule
13.1 Overall Period
Approximately 20-35 working days from order to acceptance: design and production (15-25 days), delivery (1-2), on-site installation and commissioning (2-3), training and acceptance (1-2); adjustable per customization.
13.2 Stage Schedule
| Stage | Work | Days | Responsible |
|---|---|---|---|
| 1. Survey and design | Product/site survey, design confirmation, fixture drawings | 3 | Engineer |
| 2. Production | Box, manipulator, pneumatic, acoustic, electrical, software; fixture fabrication | 15-25 | Factory |
| 3. Factory testing | Acoustic calibration, function tests, safety verification | 2 | QC |
| 4. Delivery and installation | Transport, positioning, power/air connection, fixture install | 2-3 | Engineers |
| 5. Commissioning | Probe calibration, mode tests, line interface verification | 1 | Engineer |
| 6. Training and acceptance | Operation/maintenance training, acceptance | 1-2 | PM |
13.3 Schedule Assurance
Advance production planning; experienced engineers; coordination with the client on site and line interfaces; spare parts available; contingency arrangements.
14. Construction Organization and Quality/Safety Measures
14.1 Organization Structure
– Project manager: overall responsibility, client interface, progress control;
– Technical leader: design, calibration, commissioning, training;
– Teams: mechanical, electrical and software engineers;
– QC/safety officer: quality inspection, safety supervision.
14.2 Pre-Installation Preparation
1. Technical: product/site survey, fixture drawings confirmed, technical disclosure;
2. Materials: incoming inspection (equipment, fixtures, software, certificates);
3. Site: coordinate power, air supply, work area and line interface.
14.3 Key Processes
– Positioning and leveling with adjustable feet; power/air connection verified;
– Fixture installation and product positioning check; probe calibration with standard calibrator;
– Mode tests (manual/automatic), safety function tests (light curtain, two-hand, E-stop), line interface verification;
– Acceptance per checklist with documentation.
14.4 Quality Control
– Factory testing (acoustic accuracy, repeatability, functions); incoming inspection;
– Key control points: probe calibration, box sealing, positioning accuracy, safety functions, software judgment, communication;
– Acceptance checklist with as-built documentation.
14.5 Safety and Civilized Work
– Electrical safety (certified connections, power-off during wiring); pneumatic safety (pressure checks); PPE;
– Clean work, protection of the surrounding production area; compliance with site rules;
– Emergency plans for injury, air/power failure and equipment damage.
14.6 Protection and Acceptance
Installed equipment protected; acceptance per checklist (accuracy, modes, safety, communication, documentation) jointly signed.
15. After-Sales Service
15.1 Warranty Commitment
Typically 1-2 years with free repair/replacement of non-artificial quality problems; lifetime cost-price maintenance after warranty.
15.2 Response Mechanism
7×24 hotline; remote guidance within 1 hour; on-site per region (urban 4h); urgent faults prioritized.
15.3 Service Content
Periodic inspection (seals, pneumatics, probes, software), preventive maintenance, calibration support and platform assistance.
15.4 Exclusions
Damage from misuse, unauthorized modification, force majeure and abnormal environment — paid repair available.
16. Training Plan
16.1 Audience and Objectives
Operators and O&M personnel: operate the system, change fixtures, perform maintenance and handle common faults.
16.2 Content
System principle; operation modes; fixture change; software use (test, judgment, reports); calibration; maintenance; safety and emergency procedures.
16.3 Methods and Materials
On-site training plus documentation and videos; Q&A; repeat sessions per request.
16.4 Assessment and Documentation
Practical assessment; qualified personnel certified; manuals, diagrams, calibration records and after-sales card delivered.
15. After-Sales Service
15.1 Warranty Commitment
The overall project warranty period is 2 years from the date of completion acceptance; core equipment has a 3-year warranty. During the warranty period, all failures and damage caused by product quality or construction process problems are repaired and parts replaced free of charge. After the warranty period, lifetime cost-price maintenance is provided, charging only parts cost and basic labor, ensuring long-term stable system operation.
15.2 After-Sales Response Mechanism
– A 7×24 after-sales hotline receives fault reports and technical consultations at any time;
– Within the urban area: respond within 2 hours, technicians on site within 4 hours;
– Suburban and surrounding areas: respond within 4 hours, personnel on site within 8 hours;
– General faults resolved on the spot; complex faults solved within 24 hours with a solution;
– Emergency faults get a green channel with priority dispatch of personnel and parts.
15.3 Periodic Inspection and Maintenance
During the warranty period, a free on-site inspection is provided every six months, with a comprehensive maintenance inspection annually. Inspection contents include equipment operating status, connection firmness, sealing and rust conditions, filtering/grounding performance and safety devices. After each inspection, a formal inspection report is issued recording equipment status and maintenance content with optimization suggestions.
15.4 Spare Parts Supply Guarantee
A local spare parts warehouse is established, stocking common wearing parts for quick replacement to shorten fault handling time. For uncommon special parts, a fast supply channel with the factory ensures availability within 48 hours. During warranty, non-artificial-damage spare parts are replaced free; after warranty, parts are charged at cost price without markup.
15.5 System Upgrade and Technical Support
– Free lifetime technical consultation services by phone or online at any time;
– If the customer later needs upgrades or expansions, preferential upgrade solutions and construction services are provided;
– Industry new technology and standard information is regularly pushed to customers.
16. Training Plan
16.1 Training Objectives and Audience
Training objectives: through systematic training, enable management personnel to fully understand the system structure, working principles and performance characteristics, master daily operation methods and inspection/maintenance essentials, identify common faults and handle simple problems, ensuring safe, stable and long-term operation.
Training audience: management and O&M personnel designated by the client, recommended 2-3 persons with basic electrical and equipment knowledge.
16.2 Tiered Training Content System
Level 1: Basic operation training (1 day)
– Basic principles: system concepts, structure composition, performance indicators;
– Daily operation standards: correct operation of equipment, control and safety systems;
– Daily inspection contents: daily/weekly/monthly check items;
– Safety precautions: usage prohibitions and emergency handling procedures.
Level 2: Maintenance training (1 day)
– Detailed structure of each subsystem and working principles;
– Daily maintenance methods: cleaning, fastening checks, routine care;
– Common fault identification and simple handling;
– Emergency handling procedures for power failure, fire and equipment faults.
Level 3: Advanced management training (as needed)
– Performance influencing factors and how to avoid degradation;
– Upgrade and expansion knowledge and specification requirements;
– Relevant national standards interpretation.
16.3 Training Methods and Schedule
– Methods: combination of “theory explanation + on-site practice + Q&A interaction”;
– Schedule: training arranged at the completion acceptance stage, synchronized with handover, 2 days of intensive training total; time flexibly adjustable; a free repeat training session is provided for newly assigned personnel.
16.4 Training Assessment and Documentation Delivery
– Assessment: theory written test plus practical operation; training qualification certificates issued upon passing; supplementary training for those who fail;
– Documentation delivery: complete O&M documentation, including operation and maintenance manual, equipment manuals and certificates, completion drawings and hidden work records, test reports and after-sales service contact card, all bound into volumes.
17. Anonymous Typical Project Scenarios
All project scenarios below are anonymous, generalized examples compiled from typical industry deployments; no real customer names, addresses or confidential information are disclosed.
17.1 Motor Factory Production-Line Noise Testing
A motor manufacturer deployed the semi-automatic noise test system beside its production line. The shell-type pneumatic box isolated workshop noise, achieving near-anechoic accuracy; the automatic mode with line integration tested every motor with ≤30s cycle, outputting pass/fail signals for automatic rejection. Testing cost dropped versus the previous anechoic-room sampling approach, and full-batch testing eliminated defective outflow.
17.2 Appliance Motor Sampling for a Quality Control Lab
An appliance motor supplier’s QC lab used the system for sampling and R&D testing. The manual mode with dual-probe multi-point scanning provided comprehensive noise data; the data management and report export supported quality analysis and customer submissions; the compact, relocatable design allowed the lab to adjust test stations flexibly.
17.3 Gearbox and Pump Noise Testing Expansion
A manufacturer of gearboxes and pumps expanded noise testing using the modular system: customized fixtures and probe layouts adapted to the new products; line-mode integration with MES enabled full traceability; the quick fixture change supported multiple product models on one station, significantly improving testing throughput.
18. SEO Optimization Section
All reference prices in this technical solution are in RMB (CNY) only and are for reference purposes; final quotation is subject to the confirmed configuration.
18.1 Keyword System
– Core keywords: technical design solution, system configuration, technical parameters, construction and O&M services;
– High-conversion long-tail keywords: design solution, configuration list, technical parameters, construction plan, after-sales service;
– Industry traffic keywords: system architecture, applicable standards, technical Q&A, project cases;
– Brand keywords: KITOZER, Guangzhou Lain.
18.2 SEO Tag System
– Title tag: the article title — Guangzhou Lain KITOZER;
– Meta description: Guangzhou Lain professionally provides complete technical design solutions with detailed configuration list, full-system product technical parameters, construction organization plan and after-sales service — source manufacturer customization, compliant performance, third-party testing supported;
– H1 tag: the article title;
– H2 tags: system design and product parameters, construction organization plan, after-sales service and training, engineering cases.
18.3 Internal Link Anchor Text
– Core anchor text: technical design solution, system construction;
– Long-tail anchor text: configuration list, technical parameters, construction plan;
– Related anchor text: shielding cabinet, micro-module cold aisle, integrated computer room, outdoor cabinet.
19. Official Contact Information
– Company Name: Guangzhou Lain Intelligent System Development Co., Ltd.
– Brand: KITOZER (Pioneer)
– Official Website: https://gdlain.com
– Tel: +86 139 2228 9957 (WeChat available), +86 185 2066 8845 (WeChat available)
– Address: No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China
For any inquiries about this technical design solution, configuration customization, quotation or construction services, please contact us through the information above. We provide free design consultation and tailored solutions for your specific requirements.